On SaleSale!%Off40Save $5,2015201$40%5201$5CD145VC005B001 - USED SURPLUS - EOK - GE 5CD145VC005B001
Discount-40% $ 7799 35 List:$13000.00Full Title USED SURPLUS - EOK - GE 5CD145VC005B001SKU 5CD145VC005B001Availability In Stock -
On SaleSale!%Off45Save $6,2706270$45%6270$NEW, FACTORY SEALED!KDRY2LE01-690V - TCI KDR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 1500.0 HP @ 690V | Max Current: 1500.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KDRY2LE01-690V
Discount-45% $ 7800 96 List:$14071.00Full Title TCI KDR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 1500.0 HP @ 690V | Max Current: 1500.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KDRY2LE01-690VSKU KDRY2LE01-690VManufacturer TCISeries KDR SeriesAvailability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 1 TO 2 WEEKS.Product SpecificationsEnclosure: NEMA 1 Horsepower 1500.0 HP Rated Current: 1500.0 Amps Input Voltage(s): 690 VAC Input, Output Voltage(s): 690 VAC Output Height 48 in Width 36 in Depth 36 in Weight 810 lbs -
On SaleSale!%Off42Save $5,6315631$42%5631$NEW, FACTORY SEALED!HGP0050CW3C0000 - TCI HGP NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 50.0 HP @ 600V | Max Current: 52.0 Amps | Hertz: 60.0 Hz | Contactor Option | UL Certified - HGP0050CW3C0000
Discount-42% $ 7801 31 List:$13432.00Full Title TCI HGP NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 50.0 HP @ 600V | Max Current: 52.0 Amps | Hertz: 60.0 Hz | Contactor Option | UL Certified - HGP0050CW3C0000SKU HGP0050CW3C0000Manufacturer TCISeries HarmonicGuard (HGP Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 3R Horsepower 50.0 HP Rated Current: 52.0 Amps Input Voltage(s): 540 - 600 VAC Input, Output Voltage(s): 600 VAC Output Height 39 in Width 40 in Depth 14 in Weight 246 lbs -
On SaleSale!%Off42Save $5,6315631$42%5631$NEW, FACTORY SEALED!HGL0050CW3C0000 - TCI HGL NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 50.0 HP @ 600V | Max Current: 52.0 Amps | Hertz: 60.0 Hz | Contactor Option | UL Certified - HGL0050CW3C0000
Discount-42% $ 7801 31 List:$13432.00Full Title TCI HGL NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 50.0 HP @ 600V | Max Current: 52.0 Amps | Hertz: 60.0 Hz | Contactor Option | UL Certified - HGL0050CW3C0000SKU HGL0050CW3C0000Manufacturer TCISeries HarmonicGuard (HGL Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 3R Horsepower 50.0 HP Rated Current: 52.0 Amps Input Voltage(s): 540 - 600 VAC Input, Output Voltage(s): 600 VAC Output Height 39 in Width 40 in Depth 14 in Weight 260 lbs -
On SaleSale!%Off42Save $5,6425642$42%5642$NEW, FACTORY SEALED!HSD0150AW11100 - HSD0150AW11100 - TCI, HSD, 150HP, 480/3/60,UL Type 1, Contactor, Lug Version.
Discount-42% $ 7816 41 List:$13458.00Full Title HSD0150AW11100 - TCI, HSD, 150HP, 480/3/60,UL Type 1, Contactor, Lug Version.SKU HSD0150AW11100Manufacturer TCISeries HarmonicShield (HSD Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 1 Horsepower 150.0 HP Height 43 in Width 21 in Depth 29 in Weight 350 lbs -
On SaleSale!%Off27Save $2,8812881$27%2881$NEW, FACTORY SEALED!CIMR-PU5A0077FAA - 75 HP Yaskawa P1000 Series NEMA 1 Enclosed Variable Frequency Drive | 540 - 600 VAC 3 Phase Input | 600 VAC 3 Phase Output | 77.0 Amps | CIMR-PU5A0077FAA
Discount-27% $ 7826 03 List:$10707.00Full Title 75 HP Yaskawa P1000 Series NEMA 1 Enclosed Variable Frequency Drive | 540 - 600 VAC 3 Phase Input | 600 VAC 3 Phase Output | 77.0 Amps | CIMR-PU5A0077FAASKU CIMR-PU5A0077FAAManufacturer YaskawaSeries P1000 SeriesAvailability CALL OR EMAIL US TO CHECK AVAILABILITY.Product SpecificationsHorsepower 75.0 HP Input Voltage(s): 540 - 600 VAC Input, Output Voltage(s): 600 VAC Output Rated Current: 77.0 Amps Input Phase: Three Phase Input Output Phase: Three Phase Output Phase Converter No Enclosure: NEMA 1 UV Rating None Height 29 in Width 13 in Depth 11 in Weight 99 lbs Operating Modes Sensorless (Open Loop) Vector Control, Speed Control (V / Hz), Torque Control (Constant), Torque Control (Variable) Analog Input(s) 3 Inputs (0 - 10 VDC / -10 - 10 VDC / 4 - 20 mA) Analog Output(s) 2 Outputs (0 - 10 VDC / 2 - 10 VDC / 4 - 20 mA) Control Input(s) 8 Inputs (NPN) Control Output(s) 3 Outputs (Relay) Integrated EPM Module: Not Applicable Integrated Keypad: Yes Integrated Fwd / Rev Switch: No Integrated Speed Pot: No Integrated Disconnect: No Integrated Brake Chopper: No Integrated Communications: Modbus RTU (RS-485) -
On SaleSale!%Off42Save $5,6525652$42%5652$NEW, FACTORY SEALED!HGP0040CW3C100H - TCI HGP NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 40.0 HP @ 600V | Max Current: 41.0 Amps | Hertz: 60.0 Hz | Contactor Option | Heater | PQConnect Option | UL Certified - HGP0040CW3C100H
Discount-42% $ 7831 51 List:$13484.00Full Title TCI HGP NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 40.0 HP @ 600V | Max Current: 41.0 Amps | Hertz: 60.0 Hz | Contactor Option | Heater | PQConnect Option | UL Certified - HGP0040CW3C100HSKU HGP0040CW3C100HManufacturer TCISeries HarmonicGuard (HGP Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 3R Horsepower 40.0 HP Rated Current: 41.0 Amps Input Voltage(s): 540 - 600 VAC Input, Output Voltage(s): 600 VAC Output Height 39 in Width 40 in Depth 14 in Weight 241 lbs -
On SaleSale!%Off42Save $5,6655665$42%5665$NEW, FACTORY SEALED!HGP0040CW3C1000 - TCI HGP NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 40.0 HP @ 600V | Max Current: 41.0 Amps | Hertz: 60.0 Hz | Contactor Option | PQConnect Option | UL Certified - HGP0040CW3C1000
Discount-42% $ 7848 35 List:$13513.00Full Title TCI HGP NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 40.0 HP @ 600V | Max Current: 41.0 Amps | Hertz: 60.0 Hz | Contactor Option | PQConnect Option | UL Certified - HGP0040CW3C1000SKU HGP0040CW3C1000Manufacturer TCISeries HarmonicGuard (HGP Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 3R Horsepower 40.0 HP Rated Current: 41.0 Amps Input Voltage(s): 540 - 600 VAC Input, Output Voltage(s): 600 VAC Output Height 39 in Width 40 in Depth 14 in Weight 246 lbs -
On SaleSale!%Off42Save $5,6655665$42%5665$NEW, FACTORY SEALED!HGL0040CW3C1000 - TCI HGL NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 40.0 HP @ 600V | Max Current: 41.0 Amps | Hertz: 60.0 Hz | Contactor Option | PQConnect Board Option | UL Certified - HGL0040CW3C1000
Discount-42% $ 7848 35 List:$13513.00Full Title TCI HGL NEMA 3R Enclosed 3 Phase Passive Harmonic Filter | 40.0 HP @ 600V | Max Current: 41.0 Amps | Hertz: 60.0 Hz | Contactor Option | PQConnect Board Option | UL Certified - HGL0040CW3C1000SKU HGL0040CW3C1000Manufacturer TCISeries HarmonicGuard (HGL Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 3R Horsepower 40.0 HP Rated Current: 41.0 Amps Input Voltage(s): 540 - 600 VAC Input, Output Voltage(s): 600 VAC Output Height 39 in Width 40 in Depth 14 in Weight 238 lbs -
On SaleSale!%Off42Save $5,7005700$42%5700$NEW, FACTORY SEALED!KLR950ACB7-480V - TCI KLR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 800.0 HP @ 480V | Max Current: 950.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KLR950ACB7-480V
Discount-42% $ 7897 72 List:$13598.00Full Title TCI KLR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 800.0 HP @ 480V | Max Current: 950.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KLR950ACB7-480VSKU KLR950ACB7-480VManufacturer TCISeries KLR SeriesAvailability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 1 TO 2 WEEKS.Product SpecificationsEnclosure: NEMA 1 Horsepower 800.0 HP Rated Current: 950.0 Amps Input Voltage(s): 400 - 480 VAC Input, Output Voltage(s): 480 VAC Output Height 36 in Width 29 in Depth 30 in Weight 455 lbs -
On SaleSale!%Off42Save $5,7005700$42%5700$NEW, FACTORY SEALED!KLR950ACB7-240V - TCI KLR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 400.0 HP @ 240V | Max Current: 950.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KLR950ACB7-240V
Discount-42% $ 7897 72 List:$13598.00Full Title TCI KLR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 400.0 HP @ 240V | Max Current: 950.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KLR950ACB7-240VSKU KLR950ACB7-240VManufacturer TCISeries KLR SeriesAvailability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 1 TO 2 WEEKS.Product SpecificationsEnclosure: NEMA 1 Horsepower 400.0 HP Rated Current: 950.0 Amps Input Voltage(s): 200 - 240 VAC Input, Output Voltage(s): 240 VAC Output Height 36 in Width 29 in Depth 30 in Weight 455 lbs -
On SaleSale!%Off42Save $5,7005700$42%5700$NEW, FACTORY SEALED!KLR950ACB7-600V - TCI KLR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 1000.0 HP @ 600V | Max Current: 950.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KLR950ACB7-600V
Discount-42% $ 7897 72 List:$13598.00Full Title TCI KLR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 1000.0 HP @ 600V | Max Current: 950.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KLR950ACB7-600VSKU KLR950ACB7-600VManufacturer TCISeries KLR SeriesAvailability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 1 TO 2 WEEKS.Product SpecificationsEnclosure: NEMA 1 Horsepower 1000.0 HP Rated Current: 950.0 Amps Input Voltage(s): 540 - 600 VAC Input, Output Voltage(s): 600 VAC Output Height 36 in Width 29 in Depth 30 in Weight 455 lbs -
On SaleSale!%Off42Save $5,7095709$42%5709$NEW, FACTORY SEALED!HSD0125AW31000 - HSD0125AW31000 - TCI, HSD, 125HP, 480/3/60,UL Type 3R, Contactor Version.
Discount-42% $ 7909 33 List:$13618.00Full Title HSD0125AW31000 - TCI, HSD, 125HP, 480/3/60,UL Type 3R, Contactor Version.SKU HSD0125AW31000Manufacturer TCISeries HarmonicShield (HSD Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 3R Horsepower 125.0 HP Height 43 in Width 21 in Depth 29 in Weight 305 lbs -
On SaleSale!%Off27Save $2,9152915$27%2915$NEW, FACTORY SEALED!CIMR-AU2A0110FAA - 40 HP Yaskawa A1000 Series NEMA 1 Enclosed Variable Frequency Drive | 208 - 240 VAC 3 Phase Input | 240 VAC 3 Phase Output | 85.0 Amps | CIMR-AU2A0110FAA
Discount-27% $ 7917 39 List:$10832.00Full Title 40 HP Yaskawa A1000 Series NEMA 1 Enclosed Variable Frequency Drive | 208 - 240 VAC 3 Phase Input | 240 VAC 3 Phase Output | 85.0 Amps | CIMR-AU2A0110FAASKU CIMR-AU2A0110FAAManufacturer YaskawaSeries A1000 SeriesAvailability CALL OR EMAIL US TO CHECK AVAILABILITY.Product SpecificationsHorsepower 40.0 HP Input Voltage(s): 200 - 240 VAC Input, Output Voltage(s): 240 VAC Output Rated Current: 85.0 Amps Input Phase: Three Phase Input Output Phase: Three Phase Output Phase Converter No Enclosure: NEMA 1 UV Rating None Height 21 in Width 10 in Depth 10 in Weight 46 lbs Operating Modes Sensor (Closed Loop) Vector Control (Requires Feedback Module), Sensorless (Open Loop) Vector Control, Speed Control (V / Hz), Torque Control (Constant), Torque Control (Variable) Analog Input(s) 3 Inputs (0 - 10 VDC / -10 - 10 VDC / 4 - 20 mA) Analog Output(s) 2 Outputs (0 - 10 VDC / 2 - 10 VDC / 4 - 20 mA) Control Input(s) 8 Inputs (NPN) Control Output(s) 3 Outputs (Relay) Integrated EPM Module: Not Applicable Integrated Keypad: Yes Integrated Fwd / Rev Switch: No Integrated Speed Pot: No Integrated Disconnect: No Integrated Brake Chopper: No Integrated Communications: Modbus RTU (RS-485) -
On SaleSale!%Off42Save $5,7375737$42%5737$NEW, FACTORY SEALED!HGP0025DW1C1000 - TCI HGP NEMA 1 Enclosed 3 Phase Passive Harmonic Filter | 25.0 HP @ 208V | Max Current: 74.8 Amps | Hertz: 60.0 Hz | Contactor Option | PQConnect Option | UL Certified - HGP0025DW1C1000
Discount-42% $ 7948 83 List:$13686.00Full Title TCI HGP NEMA 1 Enclosed 3 Phase Passive Harmonic Filter | 25.0 HP @ 208V | Max Current: 74.8 Amps | Hertz: 60.0 Hz | Contactor Option | PQConnect Option | UL Certified - HGP0025DW1C1000SKU HGP0025DW1C1000Manufacturer TCISeries HarmonicGuard (HGP Series)Availability BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 6 TO 8 WEEKS.Product SpecificationsEnclosure: NEMA 1 Horsepower 25.0 HP Rated Current: 74.8 Amps Input Voltage(s): 200 - 240 VAC Input, Output Voltage(s): 240 VAC Output Height 32 in Width 18 in Depth 13 in Weight 210 lbs -
NEW, FACTORY SEALED!XT3504T-5 - Baldor 50 HP, 1770 RPM, 3 Phase, 60 Hz, 326T, 1272M, TEFC, F1 - XT3504T-5 (575 VAC Only)
Full Title Baldor 50 HP, 1770 RPM, 3 Phase, 60 Hz, 326T, 1272M, TEFC, F1 - XT3504T-5 (575 VAC Only)SKU XT3504T-5Manufacturer BaldorAvailability OBSOLETE PRODUCT. TO PREVENT DOWNTIME, WE STRONGLY ADVISE CONTACTING US FOR REPAIR OR ALTERNATIVES.
None
Facility Location:
1508 W 6th St Mishawaka, IN 46544
Free Ground Shipping on Motors, Drives And Softstarters Over $350
*Cart total must exceed $350 before taxes. Some product exclusions may apply, discount is applied automatically in the cart during checkout. For remote ‘limited access’ or Residential addresses that require special lift gate services, additional fees may apply. Please specify special shipping circumstances to avoid or limit these charges.