Free Shipping on Motors Over $350!
Precision Electric, Inc.
A Family Owned
Small Business
USA Icon
Welcome, register
or login

Login

Forgot Password?
New to Precision Electric?

Register

A link to set a new password will be sent to your email address.

Have an account with Precision Electric?
Tracking
& Orders
Shop Or Ask Questions By Phone
574-256-1000
  • 0 Cart Icon
    Shopping Cart
  • Login/Register
  • Drives
    • AC Variable Frequency Drives
    • DC Variable Speed Drives
    • Need A Drive Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Softstarters
    • AC Motor Softstarters
    • Need A Softstarter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Phase Converters
    • Rotary Phase Converters
    • VFD Phase Converters For Motors
    • Need A Phase Converter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Motors
    • AC Motors
    • Need A Motor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Reactors
    • Input Line Reactors
    • Output Load Reactors
    • Need A Reactor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Filters
    • Input EMC Filters
    • Input Harmonic Line Filters
    • Output dv/dt Filters
    • Output Sinewave Filters
    • Need A Filter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Free Repair Quotes
    • Ready To Send An Item? Click Here To Get A Packing Slip For A Free Quote
    • AC Drive Repair
    • AC Motor Repair
    • DC Drive Repair
    • DC Motor Repair
    • Servo Drive Repair
    • Pump Repair
    • PCB Repair
    • Servo Motor Repair
    • Other Electronics Repair
  • On-Site Service
    • AC / DC Drives
    • AC / DC Servo Drives
    • AC / DC Servo Motors
    • AC / DC Motors
    • Computers & PCs
    • Pumps
    • Electronics & PCBs
    • Automation Systems
    • System Retrofits
    • Systems Integration
    • Preventive Maintenance
    • Vibration Analysis
    • Infrared Thermography
    • Energy Savings
  • Support
    • Call 574-256-1000
    • Contact Us
    • About
    • Product Manuals
    • Technical Blog
    • Baldor / ABB IEC And NEMA Motor Frame / Motor Size Reference Charts
    • Submit A Support Ticket
    • Request Product Return Authorization
    • Request Product Warranty Authorization
    • Request An Open Account
  • VFD Training Videos
  • Menu Menu
Wire Transfer Logo EASA Logo Free Shipping on Orders Over $350 Logo EASA Accreditation Logo AEGIS Partner Logo EASA Accreditation Logo SSL Secure Logo
TCI KDR Series Open Chassis 3.0% Impedance 3 Phase Input Line Reactor | 300.0 HP @ 600V | Max Current: 292.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KDRG45L-600V
TCI KDR Series Open Chassis 3.0% Impedance 3 Phase Input Line Reactor | 300.0 HP @ 600V | Max Current: 292.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified - KDRG45L-600V - Image 2
On Sale
Sale!
%
Off
45
Save $790
790$
45%
790
$
NEW, FACTORY SEALED!

Prices Include:

  • FREE Ground Shipping On Drives And Softstarters

    Storewide On All Drives And Softstarters Over $350*

  • Unlimited US Based Phone Support

    Contact Us Any Time At 1-574-256-1000.

  • Access To Our Team Of Engineers

    Trust Our Over 100 Years Combined Industry Experience

  • American Small Business

    Family Owned And Operated Customer Service Since 1983.

  • Hassle Free Warranty Claims

    We Help Process Warranty Replacement & Repair Claims.

TCI KDR Series Open Chassis 3.0% Impedance 3 Phase Input Line Reactor | 300.0 HP @ 600V | Max Current: 292.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified – KDRG45L-600V

Discount
-45% $ 982 95 List: $1773.00

BUILT TO ORDER. IF ORDERED TODAY, ESTIMATED TO SHIP IN 1 TO 2 WEEKS.

Quantity: 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
View Cart

Send Enquiry for TCI KDR Series Open Chassis 3.0% Impedance 3 Phase Input Line Reactor | 300.0 HP @ 600V | Max Current: 292.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified – KDRG45L-600V

Unauthorized enquiry
Enquiry email sent successfully!

Need Member, Reseller, or OEM Pricing?

Register or Login

Estimated Repair Price: $380.00+ (Our Minimum)

Request a Repair Quote
  • Specifications
  • Overview
  • Manuals

Product Specifications

ManufacturerTCI
SeriesKDR Series
Model #KDRG45L-600V
Enclosure:Not Rated
Horsepower300.0 HP
Rated Current:292.0 Amps
Input Voltage(s):540 - 600 VAC Input,
Output Voltage(s):600 VAC Output
Height9 in
Width11 in
Depth8 in
Weight65 lbs
Learn MoreYou can hover your mouse over highlighted product specs to learn more.

Description

Estimated reading time: 12 minutes

Introduction: Why Your VFD Needs a Line Reactor

Variable Frequency Drives (VFDs) are indispensable for controlling motor speed in modern industrial applications, however, they can also introduce unwanted electrical noise into the power system. To mitigate these issues, installing TCI KDR line reactors is a critical best practice for protecting your equipment and ensuring system reliability. These devices, essentially iron-core inductors, are placed on the line side of a VFD to absorb power line disturbances and smooth the current waveform. According to Wolf Automation KDRJ2LE3R, they offer an effective way to handle issues including harmonics. In short, a line reactor acts as a buffer, safeguarding your VFD investment from a volatile power grid.

Improve Power Quality with TCI KDR Line Reactors

Beyond simply protecting the drive, a line reactor plays a vital role in improving overall power quality. For instance, VFDs are non-linear loads that draw current in short pulses, creating significant harmonic distortion (THD). This distortion can cause overheating in transformers and conductors, as well as misoperation of other sensitive electronic equipment. The addition of a KDR line reactor from KDR Line Reactors adds impedance to the line, which effectively slows down the rate of current change and reduces the amplitude of these harmful harmonics. Consequently, this not only protects the VFD's input rectifier bridge from damage but also helps maintain a cleaner, more stable power environment for the entire facility.

Moreover, installing a line reactor is often necessary when multiple VFDs are present or when the drive is connected to a power source with low impedance, such as a large utility transformer. In such conditions, nuisance tripping from overvoltage faults can become a frequent problem, leading to costly downtime. A line reactor effectively "softens" the power source, absorbing voltage spikes and preventing these trips. As noted by Yaskawa AFD.04 Document, this added impedance is crucial when the power source capacity is significantly larger than the drive's rating. Therefore, a line reactor is not just an accessory but a fundamental component for building a robust and resilient motor control system.

An Overview of TCI KDR Line Reactors

At their core, TCI KDR line reactors are robust, current-limiting devices designed to protect Variable Frequency Drives (VFDs) and other sensitive equipment. Essentially, they are specialized iron-core inductors, sometimes referred to as "chokes," that are installed on the line side (input) of a VFD. According to Wolf Automation KDRJ2LE3R Line Reactor, their fundamental job is to oppose sudden changes in current, thereby smoothing out the electrical waveform. This function is particularly crucial in environments with unstable power or when a VFD is connected to a very stiff power source, such as a large utility transformer, as noted by Transcoil.

The primary benefits of installing a KDR line reactor are multifaceted, significantly enhancing system reliability and longevity. For instance, by adding impedance to the line, the reactor absorbs many of the power line disturbances, including voltage spikes, sags, and transients that could otherwise damage the VFD's input rectifier bridge. Furthermore, this added impedance plays a vital role in mitigating harmonic distortion. As explained by KDR Brochure, this helps in lowering the percentage of injected harmonics back onto the power system. Consequently, this leads to a cleaner power supply and helps in improving the total power factor of the system.

Trans-Coil, Inc. (TCI) builds its KDR reactors with high-quality materials to ensure durability in demanding industrial settings. They are typically constructed with premium electrical-grade steel laminations and copper conductors, which provides excellent performance and minimizes power losses. This robust construction ensures the reactor can handle the electrical and thermal stresses associated with VFD applications. In other words, adding a KDR line reactor not only protects the drive but also hardens the entire motor control system against common power quality issues, ultimately extending the operational life of the equipment.

Image of TCI KDR line reactors installed in an industrial control panel to provide essential protection for a variable fre...

TCI KDR line reactors are a critical first line of defense for VFDs, mitigating power quality issues and extending the life of your motor.

The Critical Role of Line Reactors in VFD Protection

To ensure the reliability of a Variable Frequency Drive (VFD), TCI KDR line reactors serve as a critical first line of defense. These components are essentially iron-core inductors, or “chokes,” installed on the line side of a VFD to buffer it from power line disturbances. According to Wolf Automation Line Reactor, their main function is to oppose sudden changes in current. Consequently, they protect the drive’s sensitive input rectifier from transient voltage spikes and surges, adding crucial impedance to the system.

Beyond transient protection, a line reactor is vital for mitigating harmonic distortion. Since VFDs are non-linear loads, they create current harmonics that can feed back into the electrical system and disrupt other equipment. The added impedance from a KDR line reactor smooths the current waveform, significantly reducing this Total Harmonic Distortion (THD). As noted by Yaskawa AFD Application Note, this is particularly important when the power source is very “stiff” with low impedance. This mitigation protects the VFD and improves the facility’s overall power quality.

The benefits also extend to improving the total power factor. By mitigating harmonics and smoothing the current draw, the reactor reduces the VFD's input current demand, which enhances the true power factor. Furthermore, this buffering reduces stress on the VFD’s internal components like DC bus capacitors and input rectifiers, leading to a longer service life and fewer nuisance trips. As KDR Line Reactor highlights, this protection is a cost-effective way to harden the entire drive system against common electrical issues.

How to Select the Right TCI KDR Line Reactor

Choosing the right TCI KDR line reactors is a critical step for ensuring the longevity and reliability of your Variable Frequency Drive (VFD) system. The primary factors to consider are the drive's full-load amp (FLA) rating, the system voltage, and the level of harmonic mitigation required for your application. As a fundamental rule, you must ensure the reactor’s continuous current rating is equal to or greater than the drive’s input current rating, a guideline highlighted by manufacturers like Yaskawa A1000 Load Reactors. Properly matching these specifications prevents reactor overload and ensures adequate protection for the VFD's sensitive input components, such as the diode bridge rectifier.

Next, you must determine the appropriate impedance level, which is typically offered as 3% (Low "Z") or 5% (High "Z"). Low "Z" reactors are generally sufficient for preventing nuisance tripping and protecting the VFD from transient overvoltage conditions. In contrast, for applications demanding more significant harmonic mitigation to meet standards like IEEE 519, a High "Z" reactor is the superior choice. According to documentation from KDR Brochure, these higher impedance models provide better reduction of Total Harmonic Distortion (THD). Consequently, this choice directly impacts the electrical noise your system introduces back onto the power grid.

Physical & Environmental Factors for TCI KDRs

In addition to electrical specifications, physical and environmental factors are crucial for proper selection and long-term reliability. For instance, TCI offers various enclosure options, such as NEMA 1 for general indoor use or UL Type 3R for outdoor protection against rain and sleet, as detailed in product literature from KDR Line Reactor. Furthermore, you must account for the ambient operating temperature and potential altitude of the installation site. Derating may be necessary in high-temperature environments or at altitudes above 2,000 meters to prevent overheating and ensure the reactor performs within its design limits.

tci kdr line reactors - A robust, industrial TCI KDR line reactor, a current-limiting device designed to protect variable fre

TCI KDR line reactors serve as a crucial first line of defense, absorbing power line disturbances to protect valuable VFDs from damage.

In summary, a methodical approach ensures you select the optimal component that aligns with both system protection needs and installation requirements. By carefully matching the reactor's ampacity to the VFD, choosing the correct impedance for your harmonic goals, and considering the operating environment, you can effectively safeguard your equipment. Following these essential selection guidelines, as outlined in resources like this Line Reactor White Paper white paper, will ultimately lead to a more robust, compliant, and efficient motor control system that minimizes downtime.

Installation and Wiring for TCI KDR Line Reactors

Proper installation is fundamental for the performance and safety of TCI KDR line reactors. First and foremost, always adhere to lockout/tagout procedures before beginning any work. The reactor must be installed on the line side, meaning it is positioned between the main power distribution and the input terminals of the Variable Frequency Drive (VFD). According to a white paper from RAE Line Reactor White Paper, this specific placement is crucial for protecting the VFD's input rectifier bridge from power line surges and reducing harmonic distortion. Consequently, this setup ensures the reactor can effectively buffer the drive from incoming disturbances.

When wiring the reactor, selecting the appropriate conductor size is a critical step that directly impacts safety and performance. All wiring should comply with the National Electrical Code (NEC) and local regulations, ensuring the cable gauge is rated for the VFD's full load amperage. It is essential to ensure that all electrical connections are securely fastened to the reactor's terminals, as loose connections can lead to overheating and potential system failure. For instance, TCI Reactor Installation Guide installation guides often emphasize verifying terminal torque specifications. This simple verification prevents many common installation errors and enhances the overall reliability of the system.

Beyond electrical connections, the physical mounting and environment are equally important for long-term reliability. TCI KDR line reactors generate heat during operation; therefore, they must be installed in a location with adequate ventilation to allow for proper cooling. As noted by KDR Line Reactors, respecting clearance requirements detailed in the installation manual prevents overheating and prolongs the life of the unit. The reactor should be mounted securely within an enclosure or on a panel to minimize vibration. Furthermore, many smaller units offer DIN rail mounting options for added convenience and streamlined panel layouts, a feature highlighted by manufacturers like Yaskawa Document TM.J7.01 when discussing power option devices.

Troubleshooting Common Line Reactor Issues

Although TCI KDR line reactors are exceptionally durable components designed for passive operation, issues can occasionally arise, often related to installation or environmental factors. Common symptoms that point to a potential problem include excessive heat from the unit, loud humming noises, or noticeable voltage drops that affect VFD performance. For instance, understanding that reactors are fundamentally iron-core inductors, as explained by Wolf Automation Line Reactor, helps in diagnosing these physical symptoms. Most issues can be resolved with systematic inspection and adherence to safety protocols.

Overheating is one of the most frequent concerns and must be addressed safely. Before conducting any inspection, always follow strict lockout/tagout procedures to de-energize the circuit completely. First, verify that the reactor has adequate clearance for airflow and that the ambient temperature does not exceed its operational limits, which are often detailed by manufacturers like KDR Brochure. Consequently, you should use a calibrated torque wrench to confirm that all electrical connections are tightened to the manufacturer's specifications, because loose terminals can generate significant resistive heat and create a fire hazard.

Troubleshooting Noise in TCI KDR Line Reactors

A diagram showing how TCI KDR line reactors protect a VFD system from power line distortion.

TCI KDR line reactors are a crucial component, acting as the first line of defense to ensure the longevity and reliability of your VFD system.

Another common issue is excessive audible noise. While a slight hum is normal due to magnetic forces in the core, a loud buzzing or vibrating sound can indicate a mechanical or electrical problem. This noise often results from loose core laminations or mounting hardware that has loosened over time. Therefore, it is crucial to check that all mounting bolts are secure. In other cases, severe harmonic content beyond what the reactor was specified for can cause excess vibration. According to documentation from Line Reactor White Paper, the reactor's primary job is to smooth the current, and extreme harmonics can over-stress the component.

Finally, if a reactor is not providing the expected VFD protection, it warrants a performance check. A qualified technician can safely measure the voltage drop across the reactor under load and compare it to the expected values found in technical data sheets from sources like Yaskawa AFD.04 Application Note. An unusually high voltage drop might suggest an internal winding issue or short. However, if the voltage is stable but performance is poor, it often means the initial reactor selection was not correctly matched to the VFD and power system characteristics, pointing to a system design issue rather than a component failure.

Preventive Maintenance for Line Reactors

One of the significant advantages of implementing TCI KDR line reactors is their minimal maintenance requirement. These devices are fundamentally passive, consisting of copper windings around an iron core, and consequently have no moving parts that wear out. According to a case study by Petco Case Study, their robust design ensures a long operational life with virtually no need for regular upkeep once installed. However, incorporating a few simple checks into your routine VFD system maintenance schedule can prevent unexpected downtime and ensure continued reliability for years to come. Therefore, a proactive approach is always recommended for critical applications.

Inspect TCI KDR Line Reactors for Heat & Dust

The cornerstone of line reactor maintenance is a thorough visual inspection, which should be performed at least annually. Technicians should look for any signs of overheating, such as discoloration or warped insulation on the windings. In addition, it is crucial to check for excessive dust or debris accumulation, as this can inhibit proper air circulation and lead to thermal issues. As noted by Wolf Automation Line Reactor, these are simple iron-core inductors, but keeping them clean is essential for performance. If the reactor is located in a harsh environment, more frequent inspections might be necessary to ensure contaminants do not compromise the unit's integrity.

Beyond visual checks, verifying the integrity of electrical connections is another critical step. Over time, thermal cycling and mechanical vibration can cause terminal screws to loosen, creating high-resistance points that generate excess heat. During a planned outage, maintenance personnel should use a calibrated torque wrench to confirm that all power connections are tightened to the manufacturer's specifications. Proper installation and placement are also key; for instance, ensuring adequate ventilation as suggested in installation guides from sources like Valinonline prevents overheating. Following these best practices, as outlined in technical papers from experts like Rae, ensures the entire VFD and motor system remains protected and efficient.

Conclusion: a Fundamental Component for VFD Reliability

In conclusion, TCI KDR line reactors are not merely optional accessories but fundamental components for any robust Variable Frequency Drive (VFD) system. Throughout this article, we have explored their critical role in safeguarding sensitive electronics from power line disturbances and mitigating harmonic distortion. Integrating a line reactor is a proactive measure that significantly enhances the reliability and extends the lifespan of VFDs and motors. As detailed by KDR Line Reactor, they are essential for conditioning the power supplied to the drive, thereby preventing a wide range of potential issues that can lead to costly downtime and equipment failure. Ultimately, their inclusion ensures a more stable and efficient operation from the outset.

Boost Power Factor & System Reliability with TCI KDR Line Reactors

The benefits of installing a line reactor extend beyond simple equipment protection; for instance, they play a pivotal role in improving the total power factor and reducing nuisance tripping caused by voltage sags or swells. This leads to a more dependable system, especially in environments with unstable power or multiple drives operating on the same line. According to VFDs Blog: Why Use a Line Reactor, proper implementation helps maintain system integrity and can assist in meeting standards like IEEE 519. Therefore, by buffering the VFD from transient overvoltages and smoothing the input current, these devices create a more controlled and predictable electrical environment, which is crucial for consistent performance.

Ultimately, investing in a TCI KDR line reactor is a cost-effective strategy for protecting significant capital investments in VFD and motor assets. The modest upfront cost pales in comparison to the expenses associated with VFD repairs, motor replacements, and unscheduled production halts. As both Yaskawa AN.AFD.04 and Line Reactor White Paper documents suggest, adding impedance to the system is a foundational best practice. For any technician, engineer, or facility manager, specifying and installing a line reactor should be a standard procedure to ensure the long-term health and reliability of their motor control systems.

Read The Full TCI KDR Line Reactors Research:

The Full TCI KDR Line Reactors ResearchDownload

KDR Series Technical Manuals

Product Manuals

  • KDR Reactor-Manual  (1.76 MB)
  • KDR Reactor IOM 30895  (2.00 MB)

Catalogs & Brochures

  • KDR-Brochure  (1.75 MB)

Facility Location:

1508 W 6th St Mishawaka, IN 46544

Free Ground Shipping on Motors, Drives And Softstarters Over $350

*Cart total must exceed $350 before taxes. Some product exclusions may apply, discount is applied automatically in the cart during checkout. For remote ‘limited access’ or Residential addresses that require special lift gate services, additional fees may apply. Please specify special shipping circumstances to avoid or limit these charges.

Certifications:

Payment Option Certifications

BBB Rating Certification



Snell Group Certification

Vibration Institute Certification

Categories

  • ABB ACS355
  • ABB Drives
  • AC Motor Speed Controllers
  • AC Tech SMVector
  • Accessories & Options
  • Articles
  • Automation & Control Systems
  • EATON SVX9000
  • Electric Motors
  • FAQ Automation
  • FAQ Electronics
  • FAQ Mechanical
  • FAQ Motor Shop
  • FAQ VFDs
  • FAQs
  • Field Experiences
  • How-To
  • HT SMVector VFD
  • HT VFDs
  • Industrial
  • Machine Shop Videos
  • News
  • Phase Converters
  • Power-Quality Components
  • Product Manuals
  • Repair & Field Services
  • Sensors & Feedback Devices
  • Service Offerings
  • Servo Drives & Motion Control
  • Servo Motors
  • Servo Motors
  • SMVector Drives
  • SMVector Series
  • Soft Starters & Motor Starters
  • Training Videos
  • Tutorials
  • Uncategorized
  • Variable Frequency Drives (VFDs)
  • Video Series

From The Blog:

  • AC Motor VFD: A Guide to How It Works & Key Benefits
  • 3 Phase Motor with VFD: A Beginner’s Wiring Guide
  • VFD 3 Phase Motor: How To Wire Step-by-Step Guide
  • 3 Phase Motor VFD: A Guide to Choosing the Right One
  • 3 Phase Motor and VFD: Step-by-Step Wiring Guide
© Copyright - Precision Electric, Inc.
  • Link to X
  • Link to Facebook
  • Link to Youtube
  • Link to LinkedIn
Link to: TCI KDR Series Open Chassis 5.0% Impedance 3 Phase Input Line Reactor | 150.0 HP @ 690V | Max Current: 155.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified – KDRG45HV-690V Link to: TCI KDR Series Open Chassis 5.0% Impedance 3 Phase Input Line Reactor | 150.0 HP @ 690V | Max Current: 155.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified – KDRG45HV-690V TCI KDR Series Open Chassis 5.0% Impedance 3 Phase Input Line Reactor | 150.0...
On Sale
Sale!
%
Off
45
Save $629
629$
45%
629
$
NEW, FACTORY SEALED!
Link to: TCI KDR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 300.0 HP @ 600V | Max Current: 292.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified – KDRG45LC4-600V Link to: TCI KDR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 300.0 HP @ 600V | Max Current: 292.0 Amps | Hertz: 50.0/60.0 Hz | UL Certified – KDRG45LC4-600V
NEW, FACTORY SEALED!
TCI KDR Series NEMA 1 Enclosed 3.0% Impedance 3 Phase Input Line Reactor | 300.0...
Scroll to top Scroll to top Scroll to top