Eaton Overcurrent Protection

Eaton overcurrent protection and Eaton current control for the Eaton9000X drive is based on motor current measurement in all three phases. In the Frame 9/ Chassis 61 Eaton drives, the current sensors are built into the IGBT SKIP modules, and the current signals are combined and fed into a 14-bit A/D converter on the lower ASIC board. The ASIC board sends the current levels to the control board via a fiber optic serial link. In the smaller Eaton Frame 8 / Chassis 5 drives (and below), the measured current signal is fed directly to the control board. The EatonSVX9000drive has a 10-bit A/D converter and the EatonSPX9000drive has a 14-bit A/D converter.

Eaton overcurrent protection for the 9000X air-cooled frequency converter ratings are based on a High Overload (IH) capability. This means the drive can provide 150% rated output current for 1 minute if the drive was operating at rated output current (IH) for at least 9 minutes. To get continued 150% overcurrent capability, the average current over the duty cycle cannot exceed the rated output current. The maximum drive output current (IS) for starting produces approximately 200% rated motor torque but because the currents are vector sums, IS is less than 200% IH. The drive can deliver IS for 2 seconds every 20 seconds. The drive current limit can be set to 200% (2 x IH) to deliver IH but to reduce the chance of an overcurrent or IGBT over temperature trip, it is better to set the current limit to 150% (1.5 x IH) or less.

The actual drive output current available to the motor is dependent on ambient temperature at the intake to the drive, restrictions in airflow to the drive, and the drive frame size. Drive frames FR4FR9 can deliver rated current (IH) at 50C. Drive frames FR10 and above can deliver rated current (IH) at 40C except for the highest ratings of a drive frame, which may be limited to 35C. The Low Overload (IL ) rating is typically used for variable torque loads where an overload is not necessary even though a 1 (out of 10) minute overload of 110% is allowed. All drive frames are limited to 40C or less for the IL rating. The rated currents of each frame depend on a reduction of switching frequency when unit temperature reaches the warning level.

Eaton overcurrent protection in the liquid-cooled drive has a Thermal maximum continuous rms current (Ith). Use this value for continuous or any overload requirements of the process. The liquid-cooled drive does not have a 1-minute overload current rating. The thermal current rating is dependent on proper coolant flow to each module and a module coolant inlet temperature of 30C. Current limit (software-function) The drive will attempt to limit drive output current to the current limit setting by overriding and lowering the frequency reference until current is within the current limit setting. If unit temperature nears the warning level, the drive will reduce the output frequency in an attempt to bring drive output current down to a continuous current that is approximately the Low Overload (IL ) current rating. The control will not allow any further overcurrent conditions until the average current over the duty cycle is less than the drives current rating. The liquid-cooled drive control will attempt to limit the output current to the current limit setting up to the drives thermal rating. The application should be designed to avoid using the current limiter for control.

The safest way to operate an Eatondrive is to keep the drive output current within ratings with appropriate ramp times or a controlled reference to the drive. If the drive software cannot prevent output current from exceeding 200% IH, a current cutter stops firing the IGBTs when the measured instantaneous value of the current exceeds 360% IH to reduce current quickly before an overcurrent trip occurs. They are re-fired on the next top of the triangle wave. The current cutter is active on select units FR8/CH5 and smaller. If the measured instantaneous value of current exceeds the trip limit value (260400% depending on drive size), all IGBTs are switched off and the drive displays an F1, overcurrent trip. The drive is protected from a short circuit at the motor if the motor leads are greater than 16 feet (5m) in length.

Only trained and experienced electricians should work withEaton overcurrent protection. For more safety information about Eaton overcurrent protection, visit the Eaton Website. For Eaton drive repair and Eaton drive replacement quotes, contact Precision Electric.