Lenze AC Tech EPM – Electronic Programming Module

The EPM contains the drives operational memory. Parameter settings are stored in the EPM and setting changes are made to the “User Settings” in the EPM.

An optional EPM Programmer (model EEPM1RA) is available that allows:

  • An EPM to be copied directly to another EPM
  • An EPM to be copied to the memory of the EPM Programmer
  • Stored files can be modified in the EPM Programmer
  • Stored files can be copied to another EPM

As the EPM Programmer is battery operated, parameter settings can be copied to an EPM and inserted into a drive without power being applied to the drive. This means that the drive will be fully operational with the new settings on the next application of power.

Additionally, when the drives parameter settings are burned into an EPM with the EPM Programmer, the settings are saved in two distinct locations; the “User Settings” and the “OEM Default Settings”. While the user settings can be modified in the drive, the OEM settings cannot. Thus, the drive can be reset not only to the “factory” drive default settings (shown in all Lenze-AC Tech owner’s manuals), but can be set to the Original Machine settings as programmed by the OEM

While the EPM can be removed for copying or to use in another drive, it must be installed for the drive to operate (a missing EPM will trigger an F_F fault)