Evaluate the Schneider Electric Company ABB on VFD Choices

ABB vs Schneider Electric VFD: open panel with an orange drive module and terminal wiring beside two screwdrivers.

If you need to evaluate the Schneider Electric company ABB on variable frequency drive (VFD) choices, you are really comparing two full product lines. A VFD, also called a drive, controls motor speed by changing the power it sends to the motor. In this guide, you will see both makers’ tiers, worked ABB examples and a buyer’s checklist.

On this page

ABB and Schneider Electric VFDs: the short evaluation

Both makers sell drives from small machine drives up to large process drives. So the choice rarely comes down to one winner. Instead, it usually comes down to power and voltage, enclosure, safety functions, networks, software and local support.

No source we reviewed ranks one brand above the other. Because of that, this article compares published specs and fit only. In order, it covers ABB tiers, Schneider tiers, a side-by-side table, the ABB models we stock, a checklist, migration, documents and software, and common mistakes.

Is ABB or Schneider Electric better for variable frequency drives?

Neither source set ranks one above the other. Instead, compare the exact models rather than the brands. For small machines, for example, the closest pair is the ABB ACS180 (0.25 to 22 kW) and the Schneider ATV320 (0.18 to 22 kW).

How ABB organizes its low-voltage VFD line

This is the first step when you evaluate the Schneider Electric company ABB on variable frequency drive (VFD) tiers. ABB groups its low-voltage AC drives into four tiers: micro, machinery, general purpose and industrial. The ACS180 and ACS255 sit in the small tiers. Above them, you find the ACS380, ACS580, ACS880 and DCS880.

Four electrical enclosures of increasing size, one orange and three navy blue, sit on a workbench with a cardboard box and
Units step up in height from left to right, showing the tier progression.

What VFD tiers does ABB offer?

  • Micro: ACS255, for panel builders and small machines.
  • Machinery: ACS180 and ACS380, for machine builders.
  • General purpose: ACS580, with ACH580 for HVAC and ACQ580 for pumping and water.
  • Industrial: ACS880, the flagship for demanding or process duty.

Older series have been replaced. For example, the ACS550 was replaced by the ACS580.

What does “all-compatible” mean for ABB VFDs?

ABB calls the ACS380, ACS580 and ACS880 part of its all-compatible portfolio. In plain terms, these drives share a similar user experience. As a result, moving up a tier should not mean learning a whole new drive. In addition, ABB lists the ACS180 as an all-compatible machinery drive.

ABB micro VFDs: ACS255

The ACS255 is a micro drive from 0.5 to 20 hp. It takes 1-phase or 3-phase input and comes in IP20 and IP66/NEMA 4X versions. IP66 means the case blocks dust and strong water jets. Also, supply voltages run from 110 to 600 V.

It gives 150% overload for one minute and 175% for 2 seconds. Its frequency range is 0 to 500 Hz. Next, control modes at 115 to 460 VAC are V/Hz and open-loop vector, and Modbus RTU is built in. ABB’s catalog calls it ideal for panel builders and OEMs. Typical uses are pumps, fans, grinders, mixers and conveyors.

ABB machinery VFDs: ACS180 and ACS380

The ACS180 is a compact, cost-effective drive for machine builders. It covers 0.25 to 22 kW (1/3 to 30 hp). In addition, it offers scalar and sensorless vector control and runs induction and permanent magnet motors.

What are the ACS380 ratings, voltages and fieldbus options?

The ACS380 is the next machinery step in the same family. It covers about the same power range as the ACS180, 0.25 to 22 kW. It comes in 200 to 240 V and 380 to 480 V classes, with single-phase input on the lower voltage class.

Modbus RTU is built in. For other networks, ABB sells plug-in fieldbus adapter modules, such as PROFIBUS, PROFINET, EtherNet/IP and EtherCAT. Confirm the exact adapter list and ratings for your type code in the ABB catalog before you order.

ABB general purpose and industrial VFDs: ACS580 and ACS880

The ACS580 is the general purpose workhorse. The ACH580 and ACQ580 are versions made for HVAC and for pumping. Meanwhile, the ACS880 is the industrial platform for high-power or process work. For more detail, our existing ACS580 guides cover that series.

How Schneider Electric organizes its Altivar VFD line

Schneider splits Altivar into two main families. First, Altivar Machine (ATV320, ATV340 and Altivar 12) targets OEM machines. Second, Altivar Process (ATV600 and ATV900) targets end-user process plants. The ATV6000 is a medium-voltage drive.

What VFD lines does Schneider Electric offer?

  • ATV320: a smart drive from 0.18 to 22 kW (0.25 to 30 hp) for 3-phase synchronous and asynchronous motors. Its catalog lists integrated safety functions per IEC 61508, with 5 safety functions in the software.
  • ATV600: aimed at pumps, fans and compressors.
  • ATV900: aimed at conveyors, cranes and mills.
  • ATV6000: medium voltage, up to 20 MW on the US page.

Be careful with Schneider’s top power ratings. For example, the US page lists ATV600 and ATV900 up to 2600 kW. However, the India page lists 800 kW, and a 2022 brochure lists 1200 kW. So confirm the ratings for your exact catalog number.

What are the ATV340 and Altivar 12 ratings, and how do they compare?

The ATV340 is a step up from the ATV320. It reaches about 75 kW on the 380 to 480 V class, so it covers larger machines than the ACS180 or ACS380. The Altivar 12 is a basic drive for small loads, from about 0.18 to 4 kW on 100 to 240 V supplies.

DriveApproximate power rangeBest fit
ABB ACS1800.25 to 22 kWCompact machines
ABB ACS3800.25 to 22 kWMachines needing more network and option choice
Schneider ATV3200.18 to 22 kWOEM machines
Schneider ATV340Up to about 75 kWLarger OEM machines
Schneider Altivar 12About 0.18 to 4 kWSimple small loads

These are rounded figures. Always confirm current and voltage for your catalog number.

ABB vs Schneider Electric VFD: side-by-side

TierABB modelSchneider modelPublished rangeAimed at
MicroACS255ATV320 IP66/65 versions for washdown (confirm in catalog)ACS255: 0.5 to 20 hpPanel builders, OEMs, washdown areas
MachineryACS180ATV320ACS180: 0.25 to 22 kW; ATV320: 0.18 to 22 kWMachine builders and OEMs
General purposeACS580ATV600Confirm per catalog numberPumps, fans, compressors
Industrial or processACS880ATV900Confirm per catalog numberDemanding process duty

Which Schneider Altivar VFD is closest to the ABB ACS180?

The ATV320 is the closest small machinery match. The ranges are nearly the same, and both target machine builders. However, do not treat them as drop-in swaps. Because parameters, mounting and wiring can differ, check both datasheets.

Which Schneider drive matches the ACS255 IP66 for washdown?

Schneider lists IP66/65 versions of the ATV320 for wet and dusty areas. They are the nearest match to the ACS255 IP66/NEMA 4X. However, the power range, voltage and NEMA rating can differ. So compare the exact catalog number against the ACS255 datasheet.

How do safety and network options compare?

ABB builds STO (safe torque off) into the ACS180 types we stock, except the 04N type. Schneider’s ATV320 also has STO, and its catalog lists more safety functions in the software. Two of them are SS1 (safe stop 1) and SLS (safely limited speed).

  • ACS180: Modbus RTU built in; check the catalog for fieldbus adapters.
  • ACS380: Modbus RTU built in; plug-in adapters add Ethernet and fieldbus networks.
  • ATV320: Modbus serial and CANopen built in; option cards add Ethernet/IP, PROFINET and others.
  • ATV340: Ethernet built in; check the catalog for added networks.

The safety integrity level (SIL) and performance level (PL) differ by model and type code. Read the safety section of each manual before you rely on them.

What this VFD comparison cannot tell you

We found no verified price, lead time or reliability data. For the ACS580 against the ATV600, therefore, compare by application, not by spec. Then compare real quotes and datasheets side by side.

ABB drives we stock: the ACS180 and ACS255 examples

Our current listing covers the 0.5 hp class. It has one ACS180 and a family of ACS255 IP66 drives. In fact, all the stocked ACS255 drives are the 0.5 hp, E1-frame class. They differ by input voltage, enclosure suffix and the +F278 option.

Two navy and gray electrical units with orange trim sit on a workbench beside a wire spool and pliers.
Bundled cables drape off the left edge, ready for routing into the housing.

ACS180-04S-02A4-2 drive (0.5 hp, 200 to 240 V)

This drive is frame R0. Its nominal rating is 2.4 A at 0.37 kW. Also, maximum output is 3.2 A.

The ACS180 gives light-duty and heavy-duty ratings in one drive. Light duty suits loads that rarely see overload. In contrast, heavy duty suits tougher starts and loads. Here are this model’s two ratings:

  • Light duty: 2.3 A at 0.37 kW.
  • Heavy duty: 1.8 A at 0.25 kW.

In every case, Imax is 180% of the heavy-duty current, allowed for 2 seconds at start.

ABB’s catalog gives a built-in EMC filter, which cuts radio noise, only for the 04S-xxxx-1 (C2) and 04S-xxxx-4 (C3) types. The 3-phase 230 V 04S-xxxx-2 types, including this 02A4-2, are Class C4 with no built-in EMC filter. They still have integrated STO (safe torque off). By contrast, the 04N type has no STO and no EMC filter (class C4). Output runs 0 to 599 Hz with a switching frequency of 1.5 to 12 kHz, and the efficiency class is IE2.

ACS255 IP66/NEMA 4X VFD: reading the part number

The part number tells you the input and rating. For instance, the last digit before the plus sign gives the voltage class. Here are our examples:

  • 01U-02A3-1: 100 to 120 V single-phase input, 2.3 A output.
  • 01U-02A3-2: 208 to 240 V single-phase input.
  • 03U-02A3-2: 208 to 240 V three-phase input.
  • 03U-01A2-4: 400 to 480 V three-phase input, 1.2 A.

Check the code before you order. For example, one shop title lists a single-phase-input model as “3 Phase Input,” but the part number code says single phase.

What do +B063, +B068 and +F278 mean on a VFD?

+B063 is the IP66/UL Type 4X enclosure without an input disconnect. Adding +F278 gives an input disconnect, a FWD/OFF/REV selector and a speed potentiometer. Our listing labels +B068 as the outdoor version. However, ABB’s ACS255 catalog calls the IP66 enclosure “for indoor use,” so check the catalog for what +B068 means before you order.

Can a single-phase VFD supply run a three-phase motor?

Yes, with the ACS255 and ACS180 single-phase-input models. ABB’s ACS255 datasheet says single-phase-input drives produce 3-phase 230 V output. That is also true of the 120 V model, which lists 3-phase 230 V output. Still, check the motor’s voltage and amps against the drive rating.

How do I size fuses, breakers, reactors and cable for these drives?

Start with the drive’s input current from the datasheet, not the motor hp. Then pick fuses or a breaker from the table in the drive’s hardware manual. Size the input cable to that current and your local electrical code. Also check the manual for the maximum motor cable length at your switching frequency.

The ACS255 catalog lists input reactors and output filters as accessories. Add them if the manual calls for them, or if your cable run is long. We do not quote fuse or cable sizes here, because they change by type code and supply network.

Where each VFD fits

Use this section to match the drive to the job when you evaluate the Schneider Electric company ABB on variable frequency drive (VFD) options.

Which ABB VFD fits washdown or wet environments?

Pick the ACS255 IP66/NEMA 4X for wet, dusty or washdown areas. It suits small pumps, fans, mixers, conveyors and grinders where you do not want a cabinet. Likewise, the +F278 version suits local start/stop and speed control. It also helps a stand-alone fractional-hp motor on single-phase power.

Other VFD fits

  • ACS180: compact machine builds and panels where IP20 is fine and you want vector control and Modbus RTU.
  • ACS580, ACH580, ACQ580: general purpose, HVAC and pumping.
  • ACS880: process duty.
  • Schneider: ATV320 or ATV340 for OEM machines, and ATV600 or ATV900 for process plants.

How to evaluate any VFD brand before you order

A fair way to evaluate the Schneider Electric company ABB on variable frequency drive (VFD) picks uses the same checks for both. Work through them in order.

Illustrated VFD cabinet wired to a motor on a workbench with a multimeter and screwdriver, ABB vs Schneider Electric VFD.
Probe leads sit beside the test unit, ready for continuity checks before power-up.

How do I evaluate a VFD brand before I buy?

  1. Match the input. Confirm supply voltage and phase. For example, some ACS255 and ACS180 models accept single-phase input and output three-phase.
  2. Match the motor. Use full-load amps, not just hp.
  3. Check overload. Then look at the duty rating you need.
  4. Check the enclosure. IP20 needs a panel. In contrast, IP66/NEMA 4X can mount on a wall in washdown areas.
  5. Check networks. Also confirm any protocol beyond Modbus RTU in the datasheet.
  6. Check safety and EMC. Look at STO, the filter and the supply network type.
  7. Check accessories. Think about brake chopper, reactors, output filters, remote keypad and fuses.
  8. Check software and support. Finally, look at tools, manuals, spares and repair options.

What are the overload ratings of the ACS255 and ACS180 VFDs?

The ACS255 gives 150% for 60 seconds and 175% for 2 seconds. The ACS180, however, gives separate light-duty and heavy-duty ratings. Its Imax is 180% of heavy-duty current for 2 seconds at start.

How do duty ratings and derating compare with Schneider?

Schneider’s ATV600 also gives normal-duty and heavy-duty ratings, so the idea matches the ACS180. The ATV320 lists its own overload figure. Compare the current at the duty you need, not the hp on the label.

Every one of these drives derates, meaning it gives less output current, in three cases:

  • Ambient temperature above the rated limit.
  • Altitude above the rated limit, often about 1000 m.
  • Switching frequency above the default setting.

The exact limits and percentages differ by model. Read the derating tables in each manual.

Do ABB VFDs have built-in Modbus, EMC filters and safety?

Modbus RTU is built into the ACS255. Likewise, ABB lists Modbus RTU for the ACS180. The ACS180-04S-xxxx-1 and -4 types have a built-in EMC filter, while the 04N has no STO or filter. Also check the supply network. The ACS180 supports TN, TT and IT networks, but the 04N 480 V type does not support a corner-grounded delta network.

The ACS255 catalog lists braking resistors, input reactors and output filters as accessories. In addition, its IP66 range has a built-in brake chopper, except frame E1. For larger ACS255 sizes, check the current datasheet. ABB documents give the IP66 maximum as 10 hp at 460 V, and 15 hp is the maximum for the 600 V IP66 range.

How to migrate from ABB to Schneider, or the reverse

How do parameters and terminals map between brands?

They do not map one to one. ABB uses numbered parameter groups, such as group 99 for motor data. Schneider uses menus with short letter codes, such as bFr for base frequency. So list your settings from the old drive, then enter them by function in the new one.

Terminal names also differ. ABB labels its inputs DI and AI, while Schneider uses LI and AI. Check the wiring diagram, the relay contacts and the STO wiring in the new manual before you connect anything.

What software do I use: Drive Composer or SoMove?

Drive Composer is ABB’s PC tool. SoMove is Schneider’s PC tool for Altivar drives. Each one reads, edits and saves parameters for its own brand only. As a result, you cannot load an ABB parameter file into a Schneider drive.

What is the Schneider commissioning workflow?

  1. Wire power, motor and control terminals, and check the STO wiring.
  2. Power up and set the motor standard and supply voltage.
  3. Enter the motor nameplate data: voltage, frequency, amps, speed and power.
  4. Set the control type, such as 2-wire or 3-wire, and the I/O.
  5. Set ramps and speed limits.
  6. Run the autotune, then test the motor with no load if you can.

Follow the exact menu path in the manual for your model.

Documents, software and support for your VFD

Where do I download ABB VFD manuals and catalogs?

Use ABB’s document library at library.abb.com. You can also reach it from abb.com/drives/documents. For Schneider, use the variable speed drives pages on se.com and the Altivar catalogs.

Isometric illustration of a desk with a laptop, eyeglasses, books, and a pen, beside a wall-mounted VFD unit wired to an
Manuals and reference papers stacked beside the workstation, ready before any wiring work begins.

What software is used to commission ABB VFDs?

ABB’s tool is Drive Composer. The entry version is free with registration, and it gives access to parameters, the event logger and basic monitoring. In contrast, Drive Composer pro has all features and comes through ABB sales channels. Drive Composer 3 is the newer tool. Because ABB describes it for common-architecture drives, check the ACS180 or ACS255 manual to confirm what tool it supports.

Cost, lead time and total ownership of a VFD

What does an ABB VFD cost and how long does delivery take?

We found no verified price or lead time data, so we give factors instead. Cost moves with hp and voltage, enclosure rating, options such as +F278, and whether the drive is in stock or built to order. For example, one distributor says ABB drives ship from stock or are built to order for complex needs.

When you ask for a quote, include accessories such as reactors, filters and a keypad. Also ask about repair or exchange options.

Common mistakes when choosing ABB or Schneider VFDs

What mistakes should I avoid when choosing a VFD?

  • Choosing by hp alone instead of motor amps and duty.
  • Ordering the wrong voltage or phase code (-1, -2 or -4).
  • Using an ACS180 04N where you need an EMC filter or STO.
  • Picking an IP20 drive for a wet area, or an IP66 drive without checking the suffix.
  • Assuming Altivar and ABB models share parameters or swap in directly.
  • Comparing power ranges from regional pages without the exact catalog number.

When to call for VFD repair or help

When should I repair or replace a VFD, or call for help?

Stop and get help if you see repeated faults, overcurrent or overtemperature trips, or damaged IP66 seals. The same goes for a drive that will not power up. Above all, do not bypass safety functions or work on a live drive.

Isometric workbench with an open orange VFD enclosure, pliers, a loose cable, and a red tag, for an ABB variable speed drive
Cutaway view of the drive housing shows internal modules with the cover removed.

When you ask for a replacement or crossover, send the full type code and nameplate data. Then Precision Electric can check the match for you.

What do common fault codes mean, and how do I reset them?

Fault names differ by brand and model, so use the fault table in your manual. These common ones give a starting point.

  • Overcurrent: ABB code 2310 or Schneider OCF. Check for a short, a locked load or a ramp that is too fast.
  • Short circuit: ABB 2340 or Schneider SCF. Check motor cable and motor insulation.
  • DC overvoltage: ABB 3210 or Schneider OSF/ObF. Lengthen the deceleration time or add braking.
  • DC undervoltage: ABB 3220 or Schneider USF. Check the supply and fuses.
  • Overheat: Schneider OHF, or an ABB temperature fault. Clean the fins and check the fan and ambient temperature.
  • Motor overload: Schneider OLF. Check load and motor settings.

To reset, first remove power and wait for the DC bus to discharge. Then fix the cause, power up and clear the fault from the keypad, a reset input or a power cycle. If the fault returns, stop and call for help.

Frequently asked questions

Is ABB or Schneider Electric better for VFDs?

Neither source set ranks one above the other. Because both sell micro and machinery drives up to process drives, compare exact models. Check power, voltage, enclosure, safety functions, networks, software and local support. For small machines, the closest pair is the ABB ACS180 (0.25 to 22 kW) and Schneider ATV320 (0.18 to 22 kW).

What is the difference between the ABB ACS180 and ACS255 VFD?

The ACS180 is a machinery drive from 0.25 to 22 kW. The ACS255, in contrast, is a micro drive from 0.5 to 20 hp, with IP20 and IP66/NEMA 4X versions and a voltage range of 110 to 600 V. For wet or washdown areas, pick the ACS255 IP66. For compact IP20 panel machines, pick the ACS180.

What do +B063 and +F278 mean on an ACS255 VFD?

+B063 is the IP66/UL Type 4X enclosure without an input disconnect. Adding +F278 gives an input disconnect, a FWD/OFF/REV selector and a speed potentiometer.

Can a single-phase VFD run a three-phase motor?

Yes, with the ABB ACS255 and ACS180 single-phase-input models. ABB’s ACS255 datasheet says single-phase-input drives produce 3-phase 230 V output. However, check the motor’s voltage and amps against the drive rating.

Where do I get ABB VFD manuals and software?

ABB’s document library at library.abb.com has catalogs and manuals. You can also reach it from abb.com/drives/documents. In addition, Drive Composer entry is a free PC tool with registration, and Drive Composer pro is sold through ABB channels.

The best way to evaluate the Schneider Electric company ABB on variable frequency drive (VFD) choices is to compare exact models, ratings and support, not brand names. So use the checklist, confirm the full type code and read the current datasheet before you order. If you want help matching a drive, a quote or a repair, contact Precision Electric or browse our ABB drives.