Eaton Electrical Guide: Drives, Catalog Numbers and Enclosures
If you search for eaton electrical, you find a huge catalog, and most plant buyers need only one part of it. This guide maps the brand, explains how Cutler-Hammer fits in, and shows where the DG1, H-Max and SPX9000 drives fit. You will also learn how to read catalog numbers, pick an enclosure and find manuals.
On this page
- What Eaton Electrical is
- Eaton electrical product categories at a glance
- Eaton electrical drive families: DG1, H-Max and SPX9000
- Eaton electrical models and ratings we stock
- How to read Eaton electrical catalog numbers
- NEMA 1 vs NEMA 12: choosing the enclosure
- Harmonics, power quality and enclosed options
- How Eaton drives compare with the alternatives
- What to check before ordering
- What should I check before ordering an Eaton electrical drive?
- How do I size fuses, breakers and reactors?
- Which option boards, keypads and fieldbus cards fit each drive?
- Which drive replaces an obsolete 9000X, SVX or Cutler-Hammer unit?
- What is the difference between constant torque and variable torque ratings?
- Where to get Eaton electrical manuals, software and parts
- Common mistakes and when to repair or call for help
- Frequently asked questions
What Eaton Electrical is
What is Eaton Electrical and what does it make?
Eaton Corporation plc calls itself a power management company. For example, it helps customers manage electrical, hydraulic and mechanical power. The electrical business covers power distribution, power quality, control and automation, circuit protection and monitoring.
Eaton splits this work into two segments. First, the Electrical Products segment includes circuit protection, industrial components, wiring devices and lighting. Second, the Electrical Systems and Services segment includes power distribution and assemblies, three-phase power quality and hazardous-duty equipment.
How do Eaton, Cutler-Hammer and Cooper brands relate?
Eaton electrical products carry either the Eaton name or the Cutler-Hammer name. As a result, many older drives and controls in plants still show Cutler-Hammer, and the two names point to the same maker. However, the source for the naming is Wikipedia, so treat it as a secondary source.
Cooper brands joined later. In fact, Eaton acquired Cooper Industries on November 30, 2012. That deal brought in Bussmann fuses and Crouse-Hinds explosion-proof equipment.
Because industrial buyers order and repair drives and motor control most often, this article focuses on those items.
Eaton electrical product categories at a glance
What are the main Eaton electrical product categories?
Eaton lists its electrical products in these groups:

- Automation and control, including motor control
- Circuit protection
- Power distribution and monitoring
- UPS backup power and monitoring
- Residential and light commercial buildings
- Services
- Cooper brands such as B-Line, Bussmann, Crouse-Hinds and Cooper Lighting
Inside automation and motor control, you find variable frequency drives (VFDs). For example, these include the PowerXL family and the older 9000X line. Also, Eaton offers enclosed drives, medium-voltage motor control and soft starters.
What is Eaton electrical supply, and what can I buy from Precision Electric?
Eaton electrical supply simply means sourcing Eaton parts and equipment from a seller. Precision Electric sells Eaton drives such as the DG1, H-Max and SPX9000 in the ranges listed below. In addition, we repair drives.
However, we do not claim a full Eaton catalog. Instead, for other Eaton lines, ask us for a quote rather than assuming stock. As an Eaton electrical distributor for these drive lines, we focus on drives, controls and parts, not the whole brand.
Eaton electrical drive families: DG1, H-Max and SPX9000
What Eaton electrical drive families are there, and how do they differ?
Eaton lists the PowerXL DG1, SVX, SPX and H-Max as the drive choices inside its PowerXL enclosed drive package. Below, this table covers the three families we stock.
| Family | Purpose | Range from Eaton | Enclosure |
|---|---|---|---|
| DG1 | General machinery | 230 V to 125 hp; 480 V to 1000 hp; 575 V to 800 hp | Open IP00, IP20, Type 1/IP21, Type 12/IP54 |
| H-Max | HVAC fans and pumps | Our listings: 100 hp at 240 V and 480 V | Type 1/IP21 or Type 12/IP54 |
| SPX9000 | High performance, large horsepower | Our listings: 1000 hp at 480 V and 600 V | Open chassis |
Because these Eaton drives and motor control products overlap a little, the job decides the pick.
Eaton DG1: the PowerXL general-purpose drive
The DG1 covers 230 V up to 125 hp (312 A), 480 V up to 1000 hp (1180 A) and 575 V up to 800 hp (820 A). Also, it has dual overload ratings: 110% for variable torque (IL) and 150% for constant torque (IH). In addition, the input voltage tolerance is -15% to +10%.
Next, the short-circuit withstand rating is 100 kAIC with fuses or circuit breakers and 5 kAIC without. Ambient temperature depends on the rating. The IL (VT) rating allows a maximum of 40 °C, or up to 60 °C with derating. The IH (CT) rating allows a maximum of 50 °C, also up to 60 °C with derating. Finally, built-in DC chokes give a typical 30% THDi.
As a result, it fits general industrial pumps, fans, conveyors and similar machines.
Eaton H-Max: the HVAC drive
The H-Max is Eaton’s HVAC drive, with the catalog prefix HMX. Because it suits variable-torque fans and pumps, you find it in building and plant air systems.
The code key from Eaton’s VFD catalog works like this:
- HMX means HVAC drive.
- Voltage digit 2 means 200-240 V. Digit 4 means 380-480 V.
- N means no brake chopper (low overload).
- The last enclosure digit is 1 for Open NEMA Type 1/IP21 or 2 for Open NEMA Type 12/IP54.
- Current digits give amps and hp. For example, 054 is 54 A/20 hp, 068 is 68 A/25 hp and 080 is 80 A/30 hp.
However, the keypad is required for Type 12/IP54 units. Also, Eaton has a PowerXL DH1 enclosed HVAC family. It offers 208 V from 1-100 hp, 230 V from 1-125 hp and 480 V from 1.5-250 hp, with Type 1 and Type 12 and 2- or 3-contactor bypass. Because it is a separate line, check each catalog before you swap one for the other.
Eaton SPX9000: high performance, large horsepower
SPX9000 drives are made for high-performance applications. For example, they can use encoder or resolver feedback. As a result, you pick one for tight speed or motion control, or when the load is very large.
Eaton’s page for the SPXH10A0-5A2N1 lists a 1000 hp, 575 V, FR13, three-phase drive. For size, the unit weighs 833 lb and measures 19.8 in D x 45.5 in H x 27.9 in W. Also, it has no brake chopper, an alphanumeric keypad and a 2-year warranty. Finally, it carries UL 508C, IEC 61800-2 and EN 61800-3 certifications.
Next, we list two 1000 hp open chassis SPX9000 drives: the SPXH10A0-4A2N1 (400-480 V, 1300 A) and the SPXH10A0-5A2N1 (540-600 V, 1030 A). To compare features with the SVX, read our existing SVX vs SPX post.
Eaton electrical models and ratings we stock
Which Eaton electrical drive models does Precision Electric list?
In total, we list 12 Eaton drives. Each one comes as a buy or repair item.

| Part number | HP | Input voltage | Amps | Type |
|---|---|---|---|---|
| DG1-32031FB-C21C | 10 | 208-240 V | 31 | NEMA 1 |
| DG1-32031FB-C54C | 10 | 208-240 V | 31 | NEMA 12 |
| DG1-34016FB-C21C | 10 | 400-480 V | 16 | NEMA 1 |
| DG1-34016FB-C54C | 10 | 400-480 V | 16 | NEMA 12 |
| DG1-34140FN-C21C | 100 | 400-480 V | 140 | NEMA 1 |
| DG1-34140FN-C54C | 100 | 400-480 V | 140 | NEMA 12 |
| HMX34AG14021-N | 100 | 400-480 V | 140 | NEMA 1 |
| HMX34AG14022-N | 100 | 400-480 V | 140 | NEMA 12 |
| HMX32AG26121-N | 100 | 208-240 V | 261 | NEMA 1 |
| HMX32AG26122-N | 100 | 208-240 V | 261 | NEMA 12 |
| SPXH10A0-4A2N1 | 1000 | 400-480 V | 1300 | Open chassis |
| SPXH10A0-5A2N1 | 1000 | 540-600 V | 1030 | Open chassis |
Do not size by the hp label alone. Instead, use the motor nameplate full-load amps and the duty, constant torque (CT) or variable torque (VT).
Eaton’s tables also show different amps for 380-440 V and 440-500 V. For example, the DG1-34140FB-C21C is 140 A CT at 380-440 V and 124 A CT at 440-500 V. So verify the amps against the nameplate and the Eaton table for your voltage.
How to read Eaton electrical catalog numbers
How do I read an Eaton electrical DG1 catalog number?
Take DG1-32031FB-C21C as the example. First, the digit after DG1- is the voltage class: 2 is 230 V (208-240 V), 4 is 400 V (380-500 V) and 5 is 600 V (525-600 V). All of them carry -15%/+10%.
Next, three characters of current code follow. For example, in the 400 V class, 016 is 16 A at 7.5 kW (10 hp) and 023 is 23 A (15 hp). Finally, the enclosure suffix comes last: C21C is IP21/Type 1 and C54C is IP54/Type 12.
To read H-Max numbers, use the code key above. SPX product pages, however, name the frame, hp and voltage. For example, SPXH10A0-5A2N1 is the FR13, 1000 hp, 575 V model. Also, our DG1 codes post has the full decoder.
How do I read the nameplate on an Eaton drive?
The nameplate carries the catalog number, input voltage range, input and output current, and the short-circuit rating (SCCR). First, decode the catalog number with the keys above. Next, match the amps and voltage to your motor and supply.
To check that a unit is genuine, compare the catalog number and serial number on the nameplate with the matching Eaton product page, and buy from a source you trust. If anything looks off, send us the nameplate details and we will help you check it.
NEMA 1 vs NEMA 12: choosing the enclosure
NEMA 1 or NEMA 12: which enclosure do I need?
Type 1 (IP21) is for clean indoor locations such as electrical rooms. Type 12 (IP54) gives more protection against dust and dripping liquids, so it suits the plant floor. Eaton enclosed drive ratings run Type 1, 12, 3R, 4/4X and 7/9. However, our listings are Type 1 and Type 12 only.

Keep these points in mind:
- For UL compliance, close field conduit openings with UL listed fittings of the same type rating as the drive enclosure.
- Eaton’s enclosed drive product aid gives an operating range of -10 °C (no frost) to +40 °C, up to +60 °C with derating.
- Humidity can be 0-95% RH, non-condensing.
- Load capacity is 100% up to 3280 ft (1000 m) altitude.
The SPX9000 SKUs are open chassis. In contrast, the others are enclosed IP21 or IP54 types.
What are the derating curves for high temperature and altitude?
Each family has its own curve, and we do not copy them here because a wrong number can damage a drive. As a rule, you may run up to 60 °C with derating, and you get full load up to 1000 m. Above that, read the derating chart in the manual for your exact model, such as the PowerXL DG1 design guide (DG040001EB). Then size the drive from the derated current.
Harmonics, power quality and enclosed options
How do I deal with harmonics on Eaton drives?
Harmonics are extra current waves that a drive pushes back into your power system. THDi is the measure of that distortion. The DG1 has built-in DC chokes and reaches a typical 30% THDi. In addition, optional passive harmonic filters can lower it below 5% (8% below 40% load).
Eaton enclosed drive packages go further. For example, a tuned passive filter delivers 5-8% THD. Likewise, an 18-pulse package delivers 3-6% THD, as read from the product aid layout.
Enclosed packages can also include bypass, disconnect and circuit-breaker options. In addition, they are designed and tested to UL 508C with a 100 kAIC short-circuit rating. Finally, confirm the short-circuit rating (SCCR) on the nameplate.
How Eaton drives compare with the alternatives
How do the DG1, H-Max and SPX9000 compare?
First, compare inside the Eaton line. Because we cannot source those claims, we do not rank Eaton against other brands. Use this list to choose:

- HVAC fan or pump: pick the H-Max.
- General machine, conveyor or pump: pick the DG1.
- Very large horsepower or encoder-based control: pick the SPX9000.
- Replacement for an older 9000X: check our existing SVX post first.
Eaton’s 9000X family has three members. The SVX9000 is full-feature, the SPX9000 is high performance and motion, and the HVX9000 is for HVAC and pumps. However, this description comes from a distributor, so treat it as secondary.
What is the difference between the DH1 and the H-Max, and when do I pick an enclosed bypass drive?
Both serve HVAC loads. The H-Max is the HMX drive we list, in Type 1 or Type 12. The DH1 is an enclosed HVAC family with Type 1 or Type 12 and 2- or 3-contactor bypass options. Eaton’s catalogs are the place to compare their feature lists, so check them before you swap one for the other.
Pick an enclosed bypass drive when the motor must keep running even if the drive is down for service or a fault. A bypass lets you run the motor straight from the line, so it suits critical fans and pumps.
What to check before ordering
What should I check before ordering an Eaton electrical drive?
Before you order, match these items:
- Input voltage, including the -15%/+10% tolerance
- Motor full-load amps
- CT or VT duty
- Enclosure type
- Ambient temperature and altitude
- The short-circuit rating your installation needs
Then confirm the exact catalog number and nameplate current. Also, ask about firmware or parameter transfer if you replace an existing drive.
How do I size fuses, breakers and reactors?
Start from the drive’s nameplate input current and the supply voltage. Then use the fuse, breaker and reactor tables in the installation manual for your model, because values differ by size and voltage. For example, the DG1 reaches 100 kAIC with fuses or circuit breakers, and it has built-in DC chokes. So you may not need an extra input reactor, but check the manual for your case.
Which option boards, keypads and fieldbus cards fit each drive?
Fit depends on the exact model, so we do not list part numbers here. First, check the option list in your drive’s installation or application manual. For example, the H-Max Type 12/IP54 needs a keypad, and the SPX9000 comes with an alphanumeric keypad. Then send us your catalog number and we will confirm the right card or keypad.
Which drive replaces an obsolete 9000X, SVX or Cutler-Hammer unit?
The right match depends on the load, voltage, amps and control needs. For example, an encoder-based SPX9000 job needs a drive with the same feedback options. Send us the nameplate and we will suggest a replacement or a repair.
To move settings, save the old drive’s parameters before you remove it. Use the keypad or the 9000X drive PC tool from Eaton’s document library. However, parameters may not map one-to-one to a new family, so check each one against the new manual.
What is the difference between constant torque and variable torque ratings?
Constant torque (CT) suits loads that need full torque at all speeds, such as conveyors. On the DG1, this is the IH rating at 150% overload. In contrast, variable torque (VT) suits fans and pumps, because the load drops as speed falls. On the DG1, this is the IL rating at 110% overload.
A drive has a higher current rating at VT than at CT. For example, Eaton lists the DG1-32031FB-C21C at 31 A CT (10 hp) and 48 A VT (15 hp).
Where to get Eaton electrical manuals, software and parts
Where do I download Eaton electrical drive manuals, catalogs and software?
Use Eaton’s document library on eaton.com. There, you find the adjustable frequency drives catalog (Volume 6, Tab 2), the 9000X drive PC tool setup file and the 9000X system software files. In addition, Eaton posts these manuals:

- PowerXL DG1 design guide (DG040001EB)
- Application manual for the PowerXL DG1 (MZ040004EN)
- Installation manual for the PowerXL DG1 (MN040002)
- DG1 and SVX enclosed drives installation manual
- PowerXL enclosed drives product aid (PA040008EN)
- 9000X AF Drives user manual (MN04001004E)
What warranty comes with Eaton drives?
Eaton Selling Policy 25-000 generally applies for warranty, with some exceptions. In addition, Eaton’s SPX9000 page shows a 2-year warranty. Likewise, our SPXH10A0-4A2N1 listing shows a 2-year manufacturer warranty. Still, read the policy for your exact part.
You can get complete drives from Precision Electric. We also list both buy and repair for these models.
Which parts are still available, and what are lead times and repair turnaround?
Availability and timing change often, so we do not post them in an article. Instead, contact us with your catalog number. We will tell you what is available, whether the part is discontinued, and the current lead time or repair turnaround.
Common mistakes and when to repair or call for help
What mistakes do buyers make with Eaton drives?
- Choosing by hp only and ignoring CT/VT amps
- Putting a Type 1 drive where Type 12 is needed
- Missing the keypad requirement on H-Max Type 12/IP54 units
- Leaving conduit openings unsealed
What do DG1, H-Max and SPX9000 fault codes mean, and how do I clear them?
The keypad shows a fault or alarm code when the drive trips. Look up that code in the fault table of your manual, such as the DG1 application manual (MZ040004EN) or the 9000X user manual (MN04001004E). We do not list every code here, because meanings differ by family and firmware.
To clear a fault, first fix the cause, such as an overload, low voltage or a wiring problem. Then reset the drive from the keypad or the control terminals. If the same code returns, the drive may need repair.
When should I get a repair?
Repair makes sense for faulted or failed drives, obsolete 9000X units and large SPX units. Also, repair often costs less downtime than a long search for a discontinued part. Then, for setup, see our SVX9000 training lessons. Finally, see our Eaton VFD Drives post for checklists.
Frequently asked questions
What is Eaton Electrical?
It is Eaton’s electrical business. Specifically, it covers power distribution, power quality, control and automation, circuit protection and monitoring. Also, products carry the Eaton or Cutler-Hammer brand. In plant maintenance, however, the most common items are drives and motor control.
Which Eaton drive should I use for HVAC fans and pumps?
The H-Max is Eaton’s HVAC drive, with the HMX catalog prefix. It comes in NEMA 1/IP21 or NEMA 12/IP54. However, the NEMA 12 version needs the keypad fitted. For general machinery, use the DG1.
What is the difference between NEMA 1 and NEMA 12 on Eaton DG1 and H-Max drives?
Type 1 (IP21) is for clean indoor locations. In contrast, Type 12 (IP54) gives more protection against dust and dripping liquids. In DG1 numbers, C21C means Type 1 and C54C means Type 12. Meanwhile, in H-Max numbers, the last digit is 1 or 2.
Does Precision Electric sell Eaton electrical supply items?
We sell Eaton drives such as the DG1, H-Max and SPX9000 in the ranges listed above, and we repair drives. However, for other Eaton product lines, ask us for a quote rather than assuming stock.
Where do I find Eaton drive manuals and software?
Use Eaton’s document library for manuals, the VFD catalog (Volume 6, Tab 2) and the 9000X drive PC tool and system software files. Also, the DG1 design guide and installation manuals are on eaton.com.
Eaton electrical covers a wide line, but for plant work the DG1, H-Max and SPX9000 drives do most of the job. So match the family to the load, size from the nameplate amps, and pick the enclosure for the room. If you need a quote, a repair or help choosing a drive, contact Precision Electric or browse our Eaton drives.