Eaton Electronics Guide: Drive Families and Catalog Number Checks
If you search for eaton electronics, you want to know which drive fits your motor and what to check before you order. First, this guide maps Eaton’s industrial drive line, decodes the catalog numbers, and lists the checks that prevent a wrong order. However, it covers drives only, not Eaton breakers, UPS units or other products.
On this page
- What “Eaton electronics” means for industrial drives and controls
- Eaton drive families at a glance
- PowerXL DG1 general-purpose drives
- How to read a DG1 catalog number
- DG1 models we stock: 10 hp and 100 hp
- Enclosed PowerXL drive packages (EGS, EGF, EGP)
- H-Max HVAC drives from Eaton
- SPX9000 (9000X) high-horsepower drives
- How to choose between Eaton drive families
- Sizing and ordering checklist for Eaton drives
- Documents, software and where to get help
- Common mistakes and when to repair an Eaton drive
- Frequently asked questions
What “Eaton electronics” means for industrial drives and controls
For industrial buyers, eaton electronics usually means Eaton’s drive and motor-control electronics. A drive, also called a VFD (variable frequency drive) or adjustable frequency drive, changes the speed of an AC motor by changing the power it receives. As a result, Eaton drives are the focus of this guide, because Precision Electric sells and repairs them.
Eaton groups its current drives under the PowerXL name. That includes the DG1, DM1, DC1, DA1, DV1X1, DF1X1 and DX1. Eaton also makes the H-Max drive for HVAC and the older 9000X family (SVX9000 and SPX9000). However, those older drives are still widely installed, and they still have Eaton SKU pages.
For that reason, this guide does not repeat startup or wiring steps. Our existing posts on SVX9000 training lessons, DG1 setup codes and SVX versus SPX cover those topics.
Eaton drive families at a glance
First, each Eaton drive family targets a different job. Next, the table below sums up what Eaton publishes for each one. However, always confirm ratings against the exact catalog number.

| Family | Best known for | Coverage and enclosure |
|---|---|---|
| PowerXL DM1 | Microdrive for small machines | Single-phase input: 115 V to 2 hp, 230 V to 7.5 hp |
| PowerXL DC1 | Simple microdrive with 14 basic parameters | Check Eaton’s page for ratings |
| PowerXL DA1 | Compact drive for panels and machines | Check Eaton’s page for ratings |
| PowerXL DV1X1 | Compact drive | 380-480 V, 0.4 to 22 kW; 200-240 V, 0.2 to 2.2 kW; IP20 |
| PowerXL DG1 | General purpose: pumps, fans, conveyors | 230 V, 400-500 V and 525-600 V classes; 0.75 to 630 kW per Eaton’s UK page |
| PowerXL DF1X1 | All-in-one open and closed loop control | 0.75 to 630 kW; includes permanent magnet motors |
| PowerXL DX1 | Premium drive | Confirm details with Eaton |
| H-Max | HVAC applications | IP21 and IP54 versions |
| SPX9000 / SVX9000 | High performance and legacy installs | Small frames up to FR13 at 1000 hp |
However, the DX1 deserves a caution. Precision Electric’s Eaton VFD overview says Eaton introduced it as a premium drive in late 2024. But Eaton did not confirm that date in our research, so check Eaton’s site for current details.
PowerXL DG1 general-purpose drives
What is the Eaton PowerXL DG1 used for?
First, the DG1 is the workhorse among Eaton drives. Eaton describes it as suited to pumps, fans and conveyor belts. In addition, it has two extra I/O expansion slots, so you can add inputs, outputs or communication cards.
For example, these features matter on the shop floor:
- A startup wizard and PC Tool software
- Active Energy Control
- Four built-in applications
- A removable keypad with copy and paste, rated IP54
- An EMI/RFI filter on all drives, meeting EMC Category C2
- An internal DC choke for THDi under 30% (the US page lists a 5% choke)
- Input surge protection and conformal coated boards
- A brake chopper circuit on FB models
- Modbus RTU on board and a fire mode
- A temperature range of -10 to +50 °C for the CT rating, up to +60 °C with derating (the VT rating tops out at +40 °C before derating)
What voltage and power range does the DG1 cover?
Eaton’s UK page lists mains voltages of 230 V, 400 V to 500 V and 525 V to 600 V. In addition, it covers 0.75 kW to 630 kW. In the US, Eaton’s overview brochure lists three-phase ratings of 230 V to 125 hp, 480 V to 250 hp and 575 V to 250 hp.
However, those top-end figures differ between sources. Some listings, including a Precision Electric PDF, state higher horsepower. So do not size a large drive from a range. Check the catalog number on Eaton’s SKU page instead.
CT and VT ratings on the DG1
First, the DG1 carries both CT and VT ratings. CT means constant torque, for loads like conveyors that need full torque at low speed. VT means variable torque, for loads like fans and centrifugal pumps. As a result, a VT rating lets the same drive handle more power.
For example, the DG1-35208FN-C21C shows the difference. At 525-600 V, it is rated 200 hp CT at 208 A, or 250 hp VT at 250 A. Then pick the rating that matches your load, and confirm the amps against the motor nameplate.
How do temperature and altitude derating work?
Derating means the drive must deliver less current when the air is hot or thin. On the DG1, the CT rating holds from -10 to +50 °C. The VT rating holds only up to +40 °C. Both can run up to +60 °C with derating, so a VT-sized drive starts to derate 10 °C sooner.
Altitude works the same way, because thin air cools less well. However, the exact percentages differ by family and frame. So use the derating curves in the manual for your catalog number, and do not copy a figure from another family.
Which option cards and fieldbuses fit the DG1?
The DG1 has two expansion slots for I/O and communication cards. Built in, Eaton lists EtherNet, RS-485, BACnet MS/TP and Modbus TCP/RTU. For anything else, such as PROFINET, check the option card list in the DG1 manual before you buy.
To identify a card you already have, read the catalog number printed on its label. Then match that number to the manual’s list, which also shows which slot the card needs. If you cannot match it, send us the number and we can help.
How to read a DG1 catalog number
First, a DG1 catalog number packs the voltage class, current, brake option and enclosure into one string. For example, take DG1-34140FN-C54C. Also, the patterns below come from Eaton’s SKU pages.

- 34 is the voltage class. 32 means 208-240 V, 34 means 380-500 V, and 35 means 525-600 V.
- 140 is the output current in amps. A “D” marks a decimal point, so DG1-344D3FB-C21C is a 4.3 A drive.
- FN means no brake chopper. FB means a brake chopper is included.
- C54C is the enclosure code.
What is the difference between C21C and C54C?
C21C is an IP21 / NEMA Type 1 enclosure. It suits a clean, dry indoor room such as an electrical room. However, C54C is IP54 / NEMA Type 12, which suits areas with dust or splashing. Finally, C00C, as on the DG1-35325FN-C00C, is an IP00 open chassis that you mount inside your own panel.
What does FB versus FN mean, and do you need a brake chopper?
A brake chopper sends extra energy to an external braking resistor when a motor slows a heavy load. FB drives have the circuit built in, and FN drives do not. However, you need one if your load must stop quickly or if it drives the motor when it slows down. If you are unsure, check how your old drive was set up before you order.
Before you buy, confirm the suffix on the Eaton SKU page for your exact catalog number.
How do you size a braking resistor for a DG1 FB drive?
First, get the minimum resistance and the brake current limit from the DG1 manual for your drive size. Never use a resistor below that ohm value, because the chopper would overload. Next, estimate the braking power from the motor power and how hard you stop the load.
Then check the resistor’s watt rating against your stop time and the number of stops per hour. A brake chopper suits short, repeated stops, not continuous braking. In addition, choose a resistor with thermal protection. We do not quote chopper current or duty limits here, because they change by frame. Read them in the manual for your catalog number.
DG1 models we stock: 10 hp and 100 hp
Precision Electric stocks DG1 drives in 10 hp and 100 hp sizes, each in NEMA 1 and NEMA 12. Next, here is how they compare.
| Catalog number | Input voltage | Output amps | Brake chopper |
|---|---|---|---|
| DG1-32031FB-C21C / -C54C (10 hp) | 208-240 V | 31 A | Yes (FB) |
| DG1-34016FB-C21C / -C54C (10 hp) | 400-480 V | 16 A | Yes (FB) |
| DG1-34140FN-C21C / -C54C (100 hp) | 400-480 V | 140 A | No (FN) |
First, the 10 hp units carry a brake chopper, and the 100 hp units do not. Also note how the voltage class changes the current. A 10 hp drive at 240 V draws 31 A, while the 480 V version draws 16 A.
Next, the enclosure choice follows the room. For example, pick NEMA 1 (C21C) for a clean, dry space. However, pick NEMA 12 (C54C) if dust or splashing is a concern. Finally, Eaton lists the DG1-32031FB-C21C as frame FR3 at 53 lb, with EtherNet, RS-485, BACnet MS/TP and Modbus TCP/RTU.
Enclosed PowerXL drive packages (EGS, EGF, EGP)
Eaton also builds enclosed drives on the DG1. The family models are EGS, EGF and EGP. So use them when you want a ready-to-mount package instead of building a panel yourself.

Eaton’s enclosed drives product aid lists these ratings and options:
- Up to 150 hp at 230 V, and up to 250 hp at 480 V and 575 V
- 100 kAIC short-circuit current rating (SCCR)
- Category 2 EMC filtering, with UL 508C and UL 508A listings
- Main breaker, or breaker and bypass, plus a pilot device kit
- NEMA 1, 12 and 3R enclosures
For harmonics, Eaton offers passive-filtered packages (IEEE 519-2014) and 18-pulse packages (3 to 6% THD). In addition, Eaton’s product aid describes a lead-time program for these drives. However, that is Eaton’s program claim, not a shop commitment, so ask us about timing for your order.
When should you pick an 18-pulse, passive-filter or standard drive?
Harmonics are extra current distortion that a drive puts back on your supply. A standard DG1 already has a DC choke for THDi under 30%, which is enough for many plants. If your utility or site must meet IEEE 519, choose a passive-filtered package. If you need the lowest distortion, choose 18-pulse, which Eaton lists at 3 to 6% THD.
The product aid (PA040008EN) explains what the EGS, EGF and EGP model letters stand for. Check it, or ask us, before you order, because we do not want to guess at those codes.
H-Max HVAC drives from Eaton
What is the Eaton H-Max drive designed for?
H-Max is Eaton’s HVAC-focused drive. In addition, it has a graphical keypad, an EMC C2 input and varnished, corrosion-resistant boards. The DG1, by contrast, is the general-purpose PowerXL drive. For fans and pumps in building systems, H-Max fits the job. For mixed machinery, however, the DG1 is the broader choice.
How do you decode an H-Max model number?
For example, take the HMX34AG07221-N. Eaton lists it as 380-480 V, 72 A, 50 hp, frame 7, with an Open NEMA Type 1 IP21 enclosure. In that number, “34” is the 380-480 V class, “072” is the amp rating, and “21” is the enclosure. In addition, the HMX32 models are the 200-240 V class.
Next, the enclosure suffix separates IP21 from IP54. The 21 version, such as HMX34AG02321-N, is Open NEMA Type 1 IP21. The 22 version, HMX34AG02322-N, is listed on Eaton’s page as NEMA Type 2 IP54. However, our own listings call the 22 units “NEMA 12”. Because the two descriptions differ, confirm the enclosure type with us or with Eaton before you order a 22 unit.
Which H-Max models are 100 hp?
We stock four 100 hp H-Max drives:
- HMX34AG14021-N (NEMA 1) and HMX34AG14022-N (22 version): 400-480 V, 140 A
- HMX32AG26121-N (NEMA 1) and HMX32AG26122-N (22 version): 208-240 V, 261 A
In short, the amps show why you should size on current. The same 100 hp needs 261 A at 240 V but only 140 A at 480 V.
However, individual H-Max SKUs can be discontinued. Eaton marks the HMX02531NA page as Discontinued, for example. But Eaton did not mark the whole line that way, so check the status of your catalog number.
SPX9000 (9000X) high-horsepower drives
What is the SPX9000 and how is the 1000 hp model rated?
First, the SPX9000 is the high-performance member of Eaton’s 9000X family. SVX is the general-purpose version, and SPX is for advanced applications. Our SVX versus SPX post covers that split in detail.

In addition, SPX covers small to very large sizes. The SPX015A1-4A1B1 is a 15 hp, 480 V, NEMA 1 drive with a brake chopper. The SPX007A2-5A4B1 is a 7.5 hp, 575 V, NEMA 12 drive. Then, at the top end, are the FR13 open-chassis drives for 1000 hp.
For example, Eaton’s page for the SPXH10A0-5A2N1 lists a 575 V, 1000 hp drive that weighs 833 lb and measures 45.5 x 27.9 x 19.8 in. It has an alphanumeric keypad, a 2-year warranty, and UL 508C, IEC 61800-2 and EN 61800-3 certifications. However, our listings show 1300 A for the 480 V SPXH10A0-4A2N1 and 1030 A for the SPXH10A0-5A2N1. So check amps against Eaton’s manual before you order.
What is the short-circuit rating of an SPX9000 or SVX9000?
Eaton’s 9000X AF Drives User Manual states a maximum symmetrical short-circuit current rating of 100 kA rms, per UL 508C. In practice, this matters for panel design. The available fault current at your drive must stay within that rating, or the panel needs added protection.
These drives are on a legacy platform. As a result, parts and repair knowledge matter, which is a good reason to buy or repair through a specialist.
How to choose between Eaton drive families
Choosing among eaton drives goes fastest in a set order. First, find the motor horsepower and full-load amps. Next, match the supply voltage class. Then decide on CT or VT duty, the enclosure and environment, the communications you need, and the short-circuit rating.
Next, the table below gives a starting point.
| Need | Start with | Why |
|---|---|---|
| Small machine or panel | DM1, DC1, DA1 or DV1X1 | Compact drives; DV1X1 is IP20, 0.4 to 22 kW at 380-480 V |
| Pumps, fans, conveyors | PowerXL DG1 | General purpose with expansion slots |
| Building HVAC | H-Max | HVAC-focused, varnished boards, C2 input |
| Permanent magnet or synchronous reluctance motors | PowerXL DF1X1 | Open and closed loop control |
| Very large or legacy 9000X systems | SPX9000 | Up to 1000 hp in FR13 |
What is the difference between CT and VT ratings?
First, use CT for loads that need steady torque at all speeds. Next, use VT for fans and centrifugal pumps, where the torque demand falls as the speed drops. Because of that, a VT rating is higher for the same drive. The DG1 example earlier, 200 hp CT at 208 A against 250 hp VT at 250 A, shows the gap.
Sizing and ordering checklist for Eaton drives
First, run through these checks before you order any Eaton drive.

- Voltage: Match the input range to your plant supply. Eaton states 380-500 V for the 34 class.
- Amps: Size on current, not only hp. A 100 hp drive is 140 A at 480 V, but 248 A (DG1-32248FN-C21C) or 261 A (H-Max) at 208-240 V.
- Enclosure: Match the suffix to the room, IP21 / Type 1 or IP54 / Type 12.
- Brake chopper: Decide between FB and FN.
- Communications: Confirm EtherNet, Modbus or BACnet MS/TP support for your network.
- Temperature: The DG1 CT rating covers -10 to +50 °C, and the VT rating covers up to +40 °C. Both can run up to +60 °C with derating, so a VT-sized drive starts derating 10 °C earlier.
- Status and warranty: Check whether the SKU is current or discontinued, and read the warranty terms.
What fuses, breakers and line reactors does a drive need?
Eaton lists the required fuse or breaker type and size in the manual for each family and catalog number. Use those tables, and do not size protection from motor hp alone. Also check the manual for line reactor advice. The DG1 already has an internal DC choke, but a reactor can help on a stiff supply with a large transformer.
How do you check available fault current against the drive’s rating?
First, find the transformer full-load amps on its nameplate. Next, divide that by the transformer impedance as a decimal. For example, a 5% transformer is 0.05. The result is a safe upper estimate of the fault current at the secondary.
Then compare it with the drive’s short-circuit rating. The 9000X manual gives 100 kA rms, and the enclosed packages list 100 kAIC. For an open DG1, read the rating in its manual. If your fault current is higher, add current-limiting fuses or a reactor, or choose a drive with a higher rating.
What is the warranty on Eaton drives?
Eaton’s DG1 SKU page states 24 months from shipment, or 36 months with Eaton certified start-up. In addition, the 36-month term covers parts, labor and travel. However, other lines differ. The SPX9000 pages show 2 years, and the discontinued HMX02531NA page shows one year from installation or 18 months from shipment. So read the page for your own catalog number.
Documents, software and where to get help
First, for specs, start with the Eaton SKU page for your catalog number. Also, many pages include a spec sheet. Eaton’s website also hosts the manuals, and each series has its own. Examples include the 9000X AF Drives User Manual (MN04001004E), the M-Max user manual (MN04020003E) and the DM1 application manual (MN040049EN).
In addition, Eaton’s VFD overview brochure (BR040002EN) gives a broad map of the families. The PowerXL enclosed drives product aid (PA040008EN) covers the enclosed packages. For that reason, use Eaton’s own documents, not third-party manual sites, so you get the right revision.
Next, for the DG1, Eaton names the PC Tool software and the startup wizard on its DG1 page. In addition, our DG1 setup posts walk through programming step by step.
Finally, Precision Electric sells and repairs drives. If you need a drive, a replacement or a repair, contact us with the full catalog number.
Common mistakes and when to repair an Eaton drive
What are common mistakes when replacing an Eaton drive?
- Ordering by hp only and missing the amp rating or voltage class.
- Mixing up C21C and C54C, or FB and FN, suffixes.
- Treating a 9000X manual as a DG1 manual.
- Ignoring DG1 derating, which starts at +50 °C for CT and +40 °C for VT.
However, each error is easy to avoid. First, read the full catalog number, then match every part of it to your nameplate and panel.
What do common fault messages mean, and what should you check first?
Fault code numbers differ between the DG1, H-Max and 9000X, so look up the exact code in your manual. However, the main fault types mean the same thing on all three. Use this list to know where to look first.
- Overcurrent: The drive saw too much output current. Check for a shorted motor or cable, a jammed load, or an acceleration time that is too short.
- Ground fault: Current leaked to ground. Test the motor and cable insulation with a megohmmeter.
- Overvoltage: The DC bus rose too high. Check for a deceleration time that is too short, a load that drives the motor, or a brake resistor problem.
- Undervoltage: The bus fell too low. Check for a supply sag, a blown fuse or a lost phase.
- Overtemperature: The drive or motor ran too hot. Check the fans, the filters, the ambient temperature and the load.
Before you reset, write down the code and the drive’s status at the time. If the fault returns after you fix the likely cause, stop and have the drive checked.
What replaces a discontinued SVX9000, SPX9000 or H-Max?
Eaton sets the replacement for each catalog number, so confirm it on that SKU page or with Eaton. Do not assume a new drive is a match for the old one. Compare voltage class, amps, enclosure and brake chopper first.
Also do not assume that keypads, option cards, terminals or parameters carry over. Check each against the new manual. Plan to enter and test the parameters yourself, and check the control wiring against the new terminal list. If you want a second opinion, send us the old and new catalog numbers.
When should you repair an Eaton drive instead of replacing it?
Repair makes sense in several cases. First, a fault may keep returning after a reset. Second, the brake chopper may have failed or the power section may be damaged. Third, Eaton may have marked the drive obsolete or discontinued. In those cases, send us the full catalog number and the fault details, and we can advise on repair or replacement.
Frequently asked questions
What does “Eaton electronics” mean when buying industrial parts?
In short, it usually means Eaton’s drive and motor-control electronics. That mainly covers the PowerXL VFDs (DG1, DM1, DC1, DA1, DV1X1, DF1X1, DX1), the H-Max HVAC drives and the 9000X (SVX/SPX) drives. However, Eaton also makes breakers and UPS units, which this guide does not cover.
Which Eaton drive is the general-purpose choice?
The PowerXL DG1. Eaton positions it as a versatile drive for pumps, fans and conveyors. In addition, it has a startup wizard, Active Energy Control, built-in EMI/RFI filtering, a DC choke and two I/O expansion slots.
What do C21C and C54C mean on a DG1 catalog number?
On Eaton’s DG1 pages, C21C is an IP21 / NEMA Type 1 enclosure and C54C is an IP54 / NEMA Type 12 enclosure. Also, FB in the same number means a brake chopper is included, and FN means none.
How is the H-Max different from the DG1?
H-Max is Eaton’s HVAC-focused drive. In addition, it has a graphical keypad, EMC C2 input and varnished, corrosion-resistant boards. The DG1, however, is the general-purpose PowerXL drive. Confirm voltage, amps and enclosure against the specific catalog number.
What is the warranty on an Eaton drive?
Eaton’s DG1 SKU page states 24 months from shipment, or 36 months with Eaton certified start-up. However, other lines differ. For example, the SPX9000 pages show 2 years, and a discontinued H-Max page shows one year from installation or 18 months from shipment. So check the page for your catalog number.
Can Precision Electric repair Eaton drives?
Yes. Precision Electric sells and repairs drives, and its Eaton product pages offer both buying and repair. So contact the shop with the full catalog number and fault details.
Eaton electronics covers a wide drive line, but the right pick comes down to voltage, amps, duty and enclosure. In short, read the full catalog number, check it against Eaton’s SKU page, and size on current. If you need help choosing, ordering or repairing an Eaton drive, contact Precision Electric or browse our Eaton drives.