Lenze i550 Cabinet VFD Guide: Specs, Models and Part Numbers

Isometric illustration of an orange Lenze i550 frequency inverter wired to terminal blocks and a motor inside a gray cabinet.

The Lenze i550 is a modular variable frequency drive for AC motors, and picking the right version takes more than choosing a power rating. This guide explains the Lenze i550 cabinet range, how to read its part numbers, which options you need, and where to find the datasheet and manuals before you order.

On this page

What the Lenze i550 is

What is the Lenze i550?

The Lenze i550 is the full-featured, modular drive in Lenze’s i500 platform. The cabinet version is IP20/NEMA Open Type, built for control cabinets. It also covers 0.25–132 kW on 120 V, 230 V, 400 V and 480 V supplies.

For example, typical uses include conveyors, winders, hoists, extruders, packaging machines, pumps and fans. Also, in North America, Lenze sells it under the AC Tech name, and it sits beside the older SMVector line.

What does “Lenze i550 cabinet” mean?

It means the version you mount inside a control cabinet. However, the other two versions are the IP66 i550 protec and the motor-mounted i550 motec. Both are built for use outside a cabinet.

Is the Lenze i550 VFD the same as an “inverter Lenze i550”?

Yes. In practice, “Lenze i550 VFD,” “inverter Lenze i550” and “Lenze i550 frequency inverter” all name the same kind of drive. For clarity, a frequency inverter, or variable frequency drive (VFD), controls the speed of an AC motor by changing the frequency it supplies.

However, the i510 is the simpler sibling in the same i500 platform. It uses a single-board design with predefined modes.

Lenze i550 cabinet: key specifications

What are the main specifications of the Lenze i550 cabinet?

First, the series datasheet lists these points for the Lenze i550 cabinet:

Isometric illustration of a gray cabinet unit with an orange side panel, a fan and heatsink on top, and manuals and a cable
Unit bolted to a base plate, with a document stack resting beside it
  • Power range of 0.25 to 132 kW.
  • Mains connections of 1×120 V, 1×230 V, 3×230 V, 3×400 V and 3×480 V.
  • Enclosure rating of IP20 / NEMA Open Type.
  • Approvals: CE, UL, CSA, EAC and RoHS.
  • Safe Torque Off (STO) through an optional module.
  • Dynamic braking through a brake resistor.
  • 5 digital inputs, 1 digital output, 1 NO/NC relay, a 0–100 kHz frequency input and an external 24 V supply.
  • Switching frequencies of 2, 4, 8 and 16 kHz.

The drive supports CANopen, EtherCAT, EtherNet/IP, Modbus RTU, Modbus TCP, POWERLINK, PROFIBUS and PROFINET. It also adds sensorless control for synchronous motors. However, servo control with encoder feedback is available only on models up to 22 kW.

How big is the Lenze i550, and how does it mount?

Cabinet drives are 60 mm wide up to 4 kW and 130 mm deep up to 11 kW. They also support zero-clearance, side-by-side mounting. As a result, you can fit several drives in a small panel. For example, the 0.25 kW 230 V models (C0.25/230-1 and C0.25/230-2) measure 155 x 60 x 130 mm. The 0.25 kW 120 V model (i550-C0.25/120-1) is a little taller at 180 x 60 x 130 mm.

What overload rating does the Lenze i550 have?

The datasheet lists 200% for 3 seconds and 150% for 60 seconds. Lenze calls this heavy duty. For example, it suits main tool drives, travelling, hoists, winders, forming and conveyors. In contrast, light duty has a restricted overload and suits pumps, fans and general horizontal materials handling.

Lenze’s brochure lists the same idea as mode S1 at 150% and mode S6 at 200%. So, check which duty the drive rating applies to before you size it.

Lenze i550 VFD models and ratings

Which Lenze i550 models and ratings are available?

First, the cabinet datasheet groups the Lenze i550 VFD range by mains supply.

Mains supplyPower range
1 AC 120 V0.25–1.1 kW
1 AC 230 V0.25–2.2 kW
1/3 AC 230 V0.25–2.2 kW
3 AC 230 V0.25–5.5 kW
3 AC 400 V and 480 V0.37–132 kW

However, older project planning manual titles say 0.25–45 kW or 0.25–75 kW. Because the current datasheets and brochures list 0.25–132 kW, use that figure.

How do I convert between HP and kW types?

One horsepower equals about 0.746 kW. So a 0.33 HP drive matches the 0.25 kW type, as the i550-C0.25/120-1 shows. However, rated currents differ between heavy duty and light duty. Read the rated current for each duty in the product data sheet for your exact type, not from the HP or kW figure alone.

How does the Lenze i550 model name work?

A name such as i550-C0.25/230-1 gives the series (i550), the mounting (C for cabinet), the power in kW, the voltage class and the phase count. In addition, the project planning manual lists names from i550-C0.25/230-1 (1-phase) and i550-C0.25/230-2 (1/3-phase) up to i550-C45/400-3.

Can the Lenze i550 run on 120 V single-phase input?

Yes. For example, the i550-C0.25/120-1 is rated 0.33 HP (0.25 kW) and takes 1/N/PE AC 90–132 V at 45–65 Hz. In contrast, the 230 V models take 170–264 V at 45–65 Hz. Also, the i550-C0.25/230-1 is single-phase input, while the i550-C0.25/230-2 takes single- or three-phase input.

However, confirm the output voltage and phase behaviour of any 120 V model in the datasheet for that exact type.

Which terminals and cable sizes apply?

Terminals depend on power and phase. For mains terminals, the maximum cable cross-section is 2.5 mm² for 0.25–0.75 kW and 6 mm² for 1.1–2.2 kW. Also, tightening torque is 0.5 Nm for 0.25–0.75 kW and 0.7 Nm for 1.1–2.2 kW. For larger sizes, fuses and cable sizes, use the tables in the operating instructions for your exact type.

How to read a Lenze i550 part number

How do I read an i550 part number?

Take I55AE125A10V01001S as an example. However, the manuals explain only some of the characters. Here is what they confirm:

Four gray boxes with three small rectangular labels each, a pair of tweezers, an orange ring in a dish, and stacked white
Four identical housings lined up diagonally, each marked with three slots for reading codes.
  • I means inverter.
  • 5 means the i550 product.
  • E means control cabinet mounting.
  • B, D and C group the terminal types: B is 1-phase, D is 1/3-phase and C is 3-phase.
  • 0 or A in the safety position: 0 means without a safety function, and A means Basic Safety – STO.

So do not guess the other characters. For example, the voltage letters and option digits such as 001, 002 and 00K can vary. Therefore, confirm each one against the product data sheet for that exact type. This also applies to the 50 Hz or 60 Hz default variant and to coated or uncoated versions.

What do our 0.33 HP part numbers show?

Our catalogue shows how the options change the number. For example, the “A” in I55AE125A1AV01001S marks a 120 V single-phase input drive. The “D” in I55AE125D1AV01001S marks the 1/3-phase 230/240 V input type (i550-C0.25/230-2), which takes single- or three-phase input. The “B” marks the single-phase-only 230 V type (C0.25/230-1). Also, the same pair with “10V” in place of “1AV” has no STO module.

The last digits match the control option. In our catalogue, 001 is Application I/O, 002 is CANopen and 00K is EtherCAT. Still, check them against the datasheet before you order.

Choosing the variant: I/O, network and STO options

Which i550 variant do I need: Application I/O, CANopen or EtherCAT?

Choose by how the drive talks to your controller. Application I/O uses wired terminals. CANopen and EtherCAT put the drive on a network. The operating instructions also list Standard I/O types.

Because a wrong fieldbus option is one of the most common ordering errors, pick the network your PLC already uses. The i550 also supports EtherNet/IP, PROFINET, PROFIBUS, Modbus and POWERLINK, so ask us if your network is not in the 0.33 HP list.

Does the i550 include STO, and is STO an emergency stop?

Not by default. STO comes from an optional safety module, and the type code shows whether it is fitted. Also, our 0.33 HP SKUs say either “STO Module Included” or “No STO Module Included.”

However, STO is not an emergency stop. The manuals say you cannot run an emergency stop per EN 60204-1 with STO alone. In addition, there is no electrical isolation between motor and inverter. For an emergency stop, you need isolation, for example a central mains contactor. In the end, you are responsible for the safety design.

Also note that the drive can restart on its own when the safety request is removed. For this reason, the commissioning manual calls for external measures per EN ISO 13849-1.

What STO safety data and wiring apply?

The i550 STO module is rated up to SIL 3 and PL e. The PFH values, mission time and the wiring of the STO inputs depend on the exact type and module. Take them from the functional safety documents and the operating instructions, and do not copy them from another drive.

Does the i550 come with a keypad?

No. All our 0.33 HP SKUs say “No Keypad.” However, you can set up the drive with a keypad you buy separately, with the Smart Keypad app through the WLAN module, or with EASY Starter software through the USB or WLAN module. So plan for one of these when you order.

Lenze i550 vs i510, i550 protec and i550 motec

What is the difference between the i510 and i550?

The i510 is a single-board basic drive for 0.25–15 kW. In contrast, the i550 is modular and goes up to 132 kW. Also, it supports all the common fieldbuses and the optional STO module. In addition, it adds sensorless synchronous-motor control and encoder servo control. For that reason, Lenze positions the i510 for cost-sensitive jobs.

Two Lenze i550 drives, a smaller navy unit and a taller orange-fronted model, beside connectors and a motor on a table.
Removable modules in front of the larger housing could be option cards or keypads.
VersionBuild and mountingPower
i510 cabinetSingle board, in a cabinet0.25–15 kW
i550 cabinetModular, in a cabinet, IP200.25–132 kW
i550 protecIP66/NEMA 4X (30–75 kW devices are IP55/NEMA 12), decentralisedUp to 75 kW
i550 motecMotor-mounted0.37–45 kW

However, protec and motec ranges vary by source, so confirm them with Lenze before you rely on them.

When should I choose i550 protec or motec instead of the Lenze i550 cabinet?

Use this short list:

  1. If you have a control cabinet with room for the drive, pick the i550 cabinet.
  2. For basic control at lower cost, the i510 fits better.
  3. When the drive must sit on a wall or machine without a cabinet, choose protec. It is available in NEMA 1 (IP31) and NEMA 4X (IP66) versions.
  4. If the drive should sit on the motor, as in distributed conveyor and material handling systems, choose motec.

In addition, the protec range includes 600 V mains types, such as the i550-P0.75/600-3, which the cabinet range does not list. The cabinet range covers 120, 230, 400 and 480 V, so mains voltages are not identical. For more detail, our existing i550 protec post covers it.

Lenze i550 datasheet, manuals and software

Where can I download the Lenze i550 datasheet?

Lenze publishes two kinds. First, the series datasheet and brochure cover the i510/i550 cabinet range. Second, a per-type product data sheet covers one exact model, and it comes with xls and csv data tables. For example, the sheet for I55AE125B1AV10000S lists the i550-C0.25/230-1 at 0.25 kW (0.33 HP) with an output frequency of 0–599 Hz.

Look on Lenze’s download pages and in the Lenze Doc Finder. Distributor sites also hold copies of Lenze documents. However, they are not official sources, so check the revision.

Which Lenze i550 manual covers selection, wiring and commissioning?

QuestionDocument
Which size and type do I need?Project planning manual
How do I wire and mount it?Operating instructions and mounting instructions
How do I set it up and set parameters?Commissioning manual
What are the exact data for my type?Per-type product data sheet
How do I use STO?Functional safety documents

The project planning manual supports dimensioning, selection and preparing the electrical and mechanical installation. In addition, you can find the manuals in the Lenze Doc Finder.

What software do I need to program a Lenze i550?

Use EASY Starter, a PC program for commissioning and diagnostics. For a wired link, connect with the USB module and a USB 2.0 cable. For a wireless link, use the WLAN module. EASY Starter also loads firmware manually. However, over EtherCAT, firmware can download automatically.

Installing and commissioning a Lenze i550 cabinet drive

How is the Lenze i550 mounted in a control cabinet?

Mount it upright in the cabinet. Because the drives support zero-clearance side-by-side mounting, you can set them next to each other. Also, follow the mounting instructions for the exact type. In addition, Lenze generally prescribes a mains choke from 30 hp (Light Duty from 20 hp).

Technician mounting an orange-and-navy drive unit onto a DIN rail inside an open cabinet, with screwdrivers, a wrench, and
The gloved hands press the module firmly against the back panel while aligning it.

How do I commission a Lenze i550 drive?

You have three routes. First, use the keypad for quick commissioning through terminal control. Next, use the Smart Keypad app through the WLAN module. Finally, use EASY Starter through the USB or WLAN module.

Follow the basic safety rules from the commissioning manual:

  • Use the drive only as directed.
  • Never commission a damaged, modified or not fully mounted drive.
  • Run it only with the required covers in place.
  • Connect and disconnect pluggable terminals only when de-energised.

The operating instructions also say you may not commission a machine until it meets the Machinery Directive (2006/42/EC) and EN 60204-1. In addition, you must meet the EMC Directive 2014/30/EU.

Common Lenze i550 ordering and application mistakes

What mistakes do buyers make when ordering a Lenze i550?

These errors cause most wrong orders:

  1. Skipping the mains voltage and phase letter in the type code.
  2. Assuming a keypad or STO module is included.
  3. Picking the wrong fieldbus variant.
  4. Treating STO as an emergency stop.
  5. Ignoring the heavy-duty or light-duty rating when sizing.
  6. Forgetting the brake resistor or mains choke on larger sizes.

So, before you order, match the full part number to the product data sheet, one character at a time.

When to repair, replace or call for help

What do i550 fault messages mean, and how do I clear them?

The drive shows its state with status LEDs, and it reports faults as messages with codes. The commissioning manual lists each code with its cause and remedy, so look up the exact code there. EASY Starter also shows the active fault during diagnostics.

Technician in a white hard hat works on a Lenze i550 cabinet VFD mounted in an open enclosure, with a laptop and tools on a
Status indicator lights glow green and orange on the front of the unit.

First, find and fix the cause, such as an overload, a wiring fault or a supply problem. Then reset the fault from the keypad, from EASY Starter or from a reset input. If the fault returns right away, the drive may need repair.

What does an i550 cost and how long does delivery take?

We do not list prices or lead times in this article. Instead, contact us for a quote and current availability.

When should I repair or replace an i550?

Send a drive for repair if it shows a fault you cannot clear, trips right after power-up, or has visible damage. Replace it with a like-for-like type when the model still fits your application. Also, match the full type code, including the safety and network options, so the new drive acts like the old one. This also applies to older AC Tech drives.

Can an i550 replace an SMVector or older AC Tech drive?

Do not assume it is a direct swap. The mounting, terminals and parameter structure differ between the lines. Before you remove the old drive, record the motor nameplate data, the acceleration and deceleration times, the control wiring and the main settings. Then enter them in the i550 with EASY Starter or the keypad, and test the drive before you return it to service.

Frequently asked questions

What is the Lenze i550?

It is Lenze’s full-featured, modular frequency inverter in the i500 platform. The cabinet version is IP20/NEMA Open Type and covers 0.25–132 kW on 120 V, 230 V, 400 V and 480 V supplies.

What does “Lenze i550 cabinet” mean?

It is the control-cabinet version of the i550. In addition, the IP66 i550 protec and the motor-mounted i550 motec are the other versions.

Does the i550 include STO and a keypad?

Not by default. STO comes from an optional safety module, and the type code shows whether it is fitted. Also, our 0.33 HP SKUs state which they include, and all say “No Keypad.”

How do I set up an i550?

You can use the keypad, the Smart Keypad app through the WLAN module, or EASY Starter software through the USB or WLAN module.

The Lenze i550 gives you a lot of choice, so the type code matters as much as the power rating. Before you buy, check the voltage, network, STO and keypad details against the datasheet. If you want help matching a part number, or need a quote or a repair, contact Precision Electric.