Free Shipping on Motors Over $350!
Precision Electric, Inc.
A Family Owned
Small Business
USA Icon
Welcome, register
or login

Login

Forgot Password?
New to Precision Electric?

Register

A link to set a new password will be sent to your email address.

Have an account with Precision Electric?
Tracking
& Orders
Shop Or Ask Questions By Phone
574-256-1000
  • 0 Cart Icon
    Shopping Cart
  • Login/Register
  • Drives
    • AC Variable Frequency Drives
    • DC Variable Speed Drives
    • Need A Drive Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Softstarters
    • AC Motor Softstarters
    • Need A Softstarter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Phase Converters
    • Rotary Phase Converters
    • VFD Phase Converters For Motors
    • Need A Phase Converter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Motors
    • AC Motors
    • Need A Motor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Reactors
    • Input Line Reactors
    • Output Load Reactors
    • Need A Reactor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Filters
    • Input EMC Filters
    • Input Harmonic Line Filters
    • Output dv/dt Filters
    • Output Sinewave Filters
    • Need A Filter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Free Repair Quotes
    • Ready To Send An Item? Click Here To Get A Packing Slip For A Free Quote
    • AC Drive Repair
    • AC Motor Repair
    • DC Drive Repair
    • DC Motor Repair
    • Servo Drive Repair
    • Pump Repair
    • PCB Repair
    • Servo Motor Repair
    • Other Electronics Repair
  • On-Site Service
    • AC / DC Drives
    • AC / DC Servo Drives
    • AC / DC Servo Motors
    • AC / DC Motors
    • Computers & PCs
    • Pumps
    • Electronics & PCBs
    • Automation Systems
    • System Retrofits
    • Systems Integration
    • Preventive Maintenance
    • Vibration Analysis
    • Infrared Thermography
    • Energy Savings
  • Support
    • Call 574-256-1000
    • Contact Us
    • About
    • Product Manuals
    • Technical Blog
    • Baldor / ABB IEC And NEMA Motor Frame / Motor Size Reference Charts
    • Submit A Support Ticket
    • Request Product Return Authorization
    • Request Product Warranty Authorization
    • Request An Open Account
  • VFD Training Videos
  • Menu Menu
Wire Transfer Logo EASA Logo Free Shipping on Orders Over $350 Logo EASA Accreditation Logo AEGIS Partner Logo EASA Accreditation Logo SSL Secure Logo
MX4PB-HD-100-4-4-NC - Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology  | 100.0 HP @ 480V | Max Current: 124.0 Amps
MX4PB-HD-100-4-4-NC - Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology  | 100.0 HP @ 480V | Max Current: 124.0 Amps - Image 2
On Sale
Sale!
%
Off
16
Save $1,179
1179$
16%
1179
$
NEW, FACTORY SEALED!

Prices Include:

  • FREE Ground Shipping On Drives And Softstarters

    Storewide On All Drives And Softstarters Over $350*

  • Unlimited US Based Phone Support

    Contact Us Any Time At 1-574-256-1000.

  • Access To Our Team Of Engineers

    Trust Our Over 100 Years Combined Industry Experience

  • American Small Business

    Family Owned And Operated Customer Service Since 1983.

  • Hassle Free Warranty Claims

    We Help Process Warranty Replacement & Repair Claims.

MX4PB-HD-100-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology | 100.0 HP @ 480V | Max Current: 124.0 Amps

Discount
-16% $ 6289 95 List: $7469.00

CALL OR EMAIL US TO CHECK AVAILABILITY.

Quantity: 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
View Cart

Send Enquiry for MX4PB-HD-100-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology | 100.0 HP @ 480V | Max Current: 124.0 Amps

Unauthorized enquiry
Enquiry email sent successfully!

Need Member, Reseller, or OEM Pricing?

Register or Login

Estimated Repair Price: $1,886.99 - $4,402.97

Request a Repair Quote
  • Specifications
  • Overview

Product Specifications

ManufacturerBenshaw
SeriesMX4PB Series
Model #MX4PB-HD-100-4-4-NC
Warranty:3 Year Manufacturer
Enclosure:NEMA 12, NEMA 4
Horsepower100.0 HP
Input Voltage(s):400 - 480 VAC Input,
Output Voltage(s):480 VAC Output
Input Phase:Three Phase Input
Output Phase:Three Phase Output
Rated Current:124.0 Amps
Height16 in
Width30 in
Depth36 in
Weight220 lbs
Learn MoreYou can hover your mouse over highlighted product specs to learn more.

Description

Estimated reading time: 14 minutes

Introduction: Your Essential Guide to Troubleshooting Benshaw MX4PB Softstarters

In modern industrial automation, effectively managing motor startup is critical for both equipment longevity and operational stability. The Benshaw MX4PB softstarters are a cornerstone of motor control technology, providing a reliable method for reducing electrical and mechanical stress during motor acceleration. These units are more than just motor starters; they are integrated systems designed for seamless performance. In fact, their robust, packaged design ensures protection and resilience in demanding environments like mining and manufacturing, as detailed by MX4PB Series Soft Starters. This guide will provide the essential, in-depth knowledge required to diagnose and resolve issues, ensuring your operations continue to run smoothly and efficiently. Consequently, understanding these systems is fundamental for any technician or engineer in the field.

Troubleshooting Benshaw MX4PB Soft Starter Issues

Even the most reliable heavy duty soft starter can encounter operational faults that lead to costly downtime. These issues can stem from various sources, including incorrect parameter settings, component wear, or external power quality problems. For instance, uncontrolled inrush current can cause significant voltage dips and place undue stress on upstream electrical components, a problem that soft starters are specifically designed to mitigate as explained in research from Journal of Engineering Research and Reports. Therefore, a systematic troubleshooting approach is crucial for quickly identifying the root cause of any problem. This involves a comprehensive understanding of Benshaw MX4PB fault codes, proper use of diagnostic tools, and strict adherence to safety protocols like Lockout/Tagout (LOTO) procedures to prevent accidents.

This guide offers a practical, step-by-step framework for troubleshooting your Benshaw motor controls. We will explore common fault scenarios, interpret diagnostic indicators, and outline preventive maintenance best practices to enhance system reliability. By managing high-torque transients, soft starters create significantly gentler mechanical behavior, which is a key benefit highlighted by Revolutionizing Soft Starters. Furthermore, with a wide range of available ratings for various motor sizes, Benshaw ensures that components are ready for immediate deployment, according to their catalog on LV Solid-State Starters Catalog. Ultimately, mastering these troubleshooting techniques will not only minimize downtime but also extend the life of your motors and associated machinery, ensuring safer and more efficient operations.

Safety First: Critical Loto Procedures for Motor Control Systems

When servicing powerful equipment like Benshaw motor starters, safety is the highest priority. First and foremost, technicians must adhere to Lockout/Tagout (LOTO) procedures before performing diagnostics or maintenance on any Benshaw MX4PB softstarters. These protocols, outlined by OSHA and NFPA 70E, are designed to prevent unexpected energization and severe injury. Even with components matched for optimal performance and safety, as noted by Benshaw MX4PB SD Soft Starter, procedural discipline is non-negotiable. Therefore, isolating electrical energy is the critical first step.

The LOTO process involves more than simply turning off a disconnect. In fact, a certified technician must identify and isolate all energy sources leading to the MX4PB unit. After de-energizing the circuit, the technician applies a personal lock and tag to the isolating device. This procedure is vital because hazardous energy remains upstream, even though the unit has a robust enclosure for demanding environments, as highlighted by MX4PB Series Soft Starters. Consequently, this physical barrier prevents accidental re-energization by another team member, safeguarding the person working on the equipment.

A technician inspecting Benshaw MX4PB softstarters in an industrial control panel to identify potential issues.

Understanding the components of Benshaw MX4PB softstarters is the first step in effective troubleshooting and maintenance, ensuring your motors run efficiently and reliably.

Finally, the most crucial step in the LOTO sequence is verification. After applying the lock and tag, the technician must try starting the equipment via its normal controls. This action confirms the system is fully de-energized and that the motor cannot start. Adhering to these industry standards eliminates assumptions and creates a safe work condition, a best practice supported by resources that discuss industrial-standard capabilities like those found at Journal of Engineering Research. Only after a successful verification can maintenance on the soft starter for the motor proceed.

Decoding Common Benshaw MX4PB Fault Codes and Alarms

Understanding the various Benshaw MX4PB fault codes is the first step in diagnosing operational issues with your heavy duty soft starter. These codes are not just warnings; they are valuable diagnostic tools that point technicians toward the root cause of a problem, whether it lies with the motor, the load, or the power supply. Consequently, the most critical resource for any technician is the official product manual, which provides a comprehensive list of faults and their corresponding corrective actions. Before attempting any troubleshooting, you should always consult the official documentation, such as the starter catalog available from LV Solid State Starters Catalog, to accurately identify the specific alarm.

Identifying Benshaw MX4PB Faults

Common faults often relate to the power system, including phase loss, undervoltage, or an issue with a Silicon Controlled Rectifier (SCR). For instance, a phase loss fault indicates that one of the three input power phases is missing, which can quickly damage a motor. The Benshaw MX4PB is designed to detect this immediately and shut down to prevent harm. Even with its robust enclosure designed for demanding environments, as detailed by benshaw.com, it is essential to perform a visual inspection. However, before opening any enclosure, you must adhere to strict Lockout/Tagout (LOTO) procedures compliant with NFPA 70E standards to ensure the system is completely de-energized and safe to work on.

Other frequent alarms are tied to the motor and load conditions, such as overcurrent, motor stall, or phase imbalance. These faults demonstrate the protective capability of Benshaw motor starters, as they prevent severe mechanical and electrical stress. For example, an overcurrent fault trips when the motor draws more current than its configured limit, which could be due to a mechanical jam or a sudden change in load. By stopping the motor, the soft starter mitigates the high-torque transients that can damage equipment, leading to the gentler mechanical behavior described by sources like Revolutionizing Soft Starters. In other words, the fault is a sign that the starter is performing its protective function correctly. Verifying that all components are matched for optimal performance, as noted by suppliers like Benshaw MX4PB Soft Starter, is a key diagnostic step.

Systematic Electrical Troubleshooting for Benshaw Motor Starters

Effective electrical troubleshooting for Benshaw motor starters requires a methodical approach, beginning with unwavering adherence to safety standards. Before any diagnostics, always implement strict Lockout/Tagout (LOTO) procedures as outlined by NFPA 70E. Consequently, once the system is de-energized and verified, the initial step involves consulting the MX4PB soft starter manual to confirm all wiring corresponds to the recommended schematics. According to Benshaw MX4PB SD Soft Starter, using matched components is essential for both optimal performance and inherent system safety. This foundational check ensures that the installation itself is not the source of the electrical fault.

Troubleshooting Benshaw MX4PB Softstarters

A certified technician applying a safety lock during a lockout-tagout procedure on a control panel with benshaw mx4pb soft...

Following correct lockout/tagout (LOTO) procedures is non-negotiable when servicing Benshaw motor starters to ensure technician safety and prevent accidental startups.

With the starter safely isolated, the next phase involves a thorough physical and electrical inspection. First, visually examine all power and control terminals for signs of overheating, discoloration, or loose connections, which can cause intermittent issues. Next, use a calibrated multimeter to verify the presence of correct input voltage (L1, L2, L3) and control voltage at the specified terminals. It's also critical to confirm that the motor's nameplate data aligns with the soft starter's programmed parameters, as a mismatch can lead to persistent faults. As detailed in its catalog, the availability of benshaw.com starters across a wide range of ratings means technicians must ensure the installed unit is correctly sized for the motor load.

If input power is correct and connections are secure, the focus should then shift to the Silicon Controlled Rectifiers (SCRs) and control logic. An incorrect control signal from a PLC or external device can prevent the starter from operating; therefore, you should validate the start/stop signal integrity. Furthermore, you can test the SCRs for shorts or open circuits using a multimeter's diode check function. A faulty SCR is a common failure point that can create electrical stress similar to the voltage dips and component strain caused by inrush current, a phenomenon detailed by Journal of Engineering Research and Reports. Moreover, ensuring the starter is protected within a robust enclosure, as highlighted by MX4PB Series Soft Starters, helps prevent environmental factors from causing these electrical issues.

Testing the Silicon Controlled Rectifiers (SCRS)

When troubleshooting Benshaw motor starters, the Silicon Controlled Rectifiers (SCRs) are fundamental components to inspect, as they control the voltage supplied to the motor. Before beginning any diagnostic work, it is absolutely critical to follow strict Lockout/Tagout (LOTO) procedures to ensure the starter is completely de-energized. The primary function of these SCRs is to mitigate the damaging effects of inrush current, which can cause significant voltage dips and stress on equipment, as detailed in research from Journal of Engineering and Rural Research. Consequently, a failure in one of these solid-state devices often results in a fault code and prevents the motor from starting correctly.

To test the SCRs, you will need a multimeter with a diode test function. First, after confirming the unit is de-energized via LOTO, disconnect the motor leads from the soft starter's output terminals. Next, set your multimeter to the diode test setting and test between the input (L1, L2, L3) and output (T1, T2, T3) terminals for each phase. A healthy SCR should read as an open circuit (OL). In contrast, a reading near zero indicates a shorted SCR that requires immediate replacement. This controlled power application is what allows for the significantly gentler mechanical operation that soft starters provide, as noted by Revolutionizing Production Soft Starters. Verifying the integrity of each SCR is a crucial step in diagnosing the robust systems found in demanding environments described by MX4PB Series Soft Starters.

Diagnosing Mechanical and Motor Load-related Problems

When troubleshooting Benshaw motor starters, it is essential to look beyond the electrical system. Consequently, many faults attributed to the starter are actually protective responses to downstream mechanical problems. A soft starter is designed to prevent the mechanical shock of high-torque transients, a benefit detailed by sources like Revolutionizing Production Soft Starters. Therefore, before inspecting any components, you must always follow strict Lockout/Tagout (LOTO) procedures to ensure the equipment is completely de-energized and cannot start unexpectedly. Safety must be the top priority during any diagnostic work.

Technician reviewing the display of one of the Benshaw MX4PB softstarters to diagnose a specific fault code and determine ...

A clear understanding of the fault codes displayed on Benshaw MX4PB softstarters is essential for quick and effective troubleshooting, helping to minimize downtime and maintain operational efficiency.

A common cause for trips is an overload condition originating from the driven equipment. For instance, problems such as a seized bearing, a blockage in a pump, or a jammed conveyor belt will drastically increase the current required by the motor. The Benshaw MX4PB soft starter correctly identifies this excessive current draw as a fault and trips to protect the motor from damage. This function aligns with broader industrial goals of managing system stress for greater efficiency, as discussed by the International Energy Agency (IEA). In other words, the fault code points to a symptom, not the root cause.

After ensuring a safe LOTO state, the first diagnostic step is to physically inspect the load. Attempt to rotate the motor shaft by hand; if it is immobile or difficult to turn, the problem is almost certainly mechanical. Additionally, check for misalignment between the motor and the connected machinery, as this can introduce significant binding and friction. The robust, enclosed design of these starters, noted on MX4PB Series Soft Starters, makes them suitable for harsh environments where these issues are prevalent. Ultimately, resolving the physical obstruction or misalignment is necessary before the starter can be safely reset and operated.

Resolving Common MX4PB Installation and Commissioning Errors

Proper MX4PB installation is crucial for the long-term reliability of Benshaw motor starters. Although these units are designed with matched components for simplified setup, as highlighted by sources like Benshaw MX4PB Soft Starter, several common errors can arise during commissioning. These issues typically fall into three categories: incorrect wiring connections, mismatched parameter settings, or inadequate grounding. Consequently, taking a systematic approach from the beginning is essential to prevent startup delays and potential equipment damage.

To begin with, wiring errors are a frequent source of problems. It is imperative to verify that control power, line voltage, and load connections precisely match the diagrams in the MX4PB soft starter manual. A common mistake, for instance, is reversing the line and load side connections, which can cause immediate damage to the starter's SCRs upon energization. Given that these units are often deployed in demanding environments, as noted by MX4PB Series Soft Starters, ensuring all terminal connections are secure and correctly torqued is fundamental for robust performance. Furthermore, confirming the control voltage source is stable and correctly wired prevents erratic behavior of the internal logic.

Another critical area involves configuring the starter’s operational parameters. Default factory settings are rarely optimized for a specific application, meaning technicians must program values such as motor Full Load Amps (FLA), ramp time, and initial torque based on the motor's nameplate data. A failure to accurately set the FLA, for example, can lead to inadequate motor overload protection. The wide range of motor sizes these starters support, detailed in documentation from benshaw.com, makes this step particularly important. Adhering to these industrial-standard setup procedures ensures the soft starter functions efficiently and safely, in line with best practices discussed in sources like the overview found at doi.org.

Verifying and Adjusting Key Parameters in Benshaw MX4PB Softstarters

Technician performing systematic electrical troubleshooting on benshaw mx4pb softstarters with a multimeter to diagnose an...

A systematic approach, starting with a visual inspection and safe electrical testing, is key to successfully troubleshooting Benshaw motor starters.

Properly configuring the parameters on Benshaw MX4PB softstarters is fundamental to protecting the motor and the driven mechanical load. Before making any adjustments, it is absolutely critical to follow all Lockout/Tagout (LOTO) procedures and consult the official MX4PB soft starter manual. The primary settings—Start Ramp, Current Limit, and Stop Ramp—dictate the motor's behavior during its most stressful phases. For instance, ensuring these components are matched and correctly set is vital for achieving both optimal performance and safety, a point emphasized by retailers like Benshaw MX4PB SD Soft Starter. These initial settings provide the foundation for reliable operation.

Optimizing MX4PB Soft Starter Ramp & Current

The Start Ramp and Current Limit parameters work together to manage the initial power surge. Specifically, the Start Ramp sets the duration for the voltage to increase from its initial level to full voltage, allowing for a smooth acceleration. The Current Limit, on the other hand, acts as a ceiling to prevent excessive inrush current, which can cause voltage dips and stress upstream components, as detailed in academic research from Journal of Engineering Research and Reports. Setting the ramp too short or the current limit too low can cause the motor to stall or trip. Conversely, proper adjustment leads to the gentler mechanical behavior that soft starters are known for, significantly reducing high-torque transients as explained by industry experts at Revolutionizing Soft Starters.

Equally important is the Stop Ramp parameter, which controls the deceleration of the motor. This feature is particularly crucial in applications like pumping, where an abrupt stop can cause water hammer and damage the system. In addition, verifying the electronic motor overload settings ensures the starter provides continuous protection based on the motor's full-load ampere (FLA) rating. Therefore, technicians should carefully review the full range of available settings detailed in official documentation, such as the catalog from benshaw.com. Fine-tuning these key parameters ultimately enhances system longevity and operational efficiency.

Preventive Maintenance Best Practices for Heavy Duty Soft Starters

Proactive preventive maintenance is crucial for ensuring the long-term reliability of any heavy duty soft starter, including the Benshaw MX4PB series. Following a consistent schedule not only extends the operational life of the unit but also significantly reduces the risk of unexpected and costly downtime. Above all, every maintenance task must begin with the strict application of Lockout/Tagout (LOTO) procedures as defined by NFPA 70E standards. This essential safety step ensures the system is completely de-energized, which, as noted by sources like Benshaw MX4PB-SD Soft Starter, is fundamental for achieving both optimal performance and personnel safety.

The next step involves a thorough visual and mechanical inspection of the soft starter. In industrial settings, it's particularly important to check for any accumulation of dust, moisture, or corrosive agents within the enclosure, which is designed for robust protection as detailed by MX4PB Series Soft Starters. Furthermore, you should verify the tightness of all power and control wiring connections. Over time, thermal cycling can cause terminal screws to loosen, leading to increased resistance, overheating, and potential failure points. A calibrated torque wrench should be used to confirm connections meet the manufacturer's specifications.

Finally, effective thermal management is a cornerstone of solid-state starter longevity. You must inspect all cooling fans to ensure they are operational and that airflow is not obstructed. Similarly, check that the SCR heatsinks are clean and free of debris, as this allows for proper heat dissipation. Improper cooling can quickly lead to component degradation and contributes to the kind of system-wide stress discussed in academic research from sources like Journal of Engineering Research. Consequently, maintaining a clear and cool operating environment is one of the most effective preventive measures you can take for your Benshaw motor controls.

Conclusion: Enhancing Reliability and Uptime

Ultimately, mastering the troubleshooting and maintenance of Benshaw MX4PB softstarters is fundamental to ensuring operational continuity and protecting valuable motor assets. By applying the systematic diagnostic procedures, safety protocols, and preventive measures detailed throughout this guide, technicians can confidently address nearly any issue that arises. The core function of these Benshaw motor starters is to provide smooth acceleration, which, as noted by Revolutionizing Production Soft Starters, results in significantly gentler mechanical behavior. Consequently, this careful management reduces wear and tear on everything from gearboxes to conveyor belts, directly enhancing system longevity.

The robust, packaged design of the MX4PB series is built for resilience in demanding industrial settings, as highlighted by MX4PB Series Soft Starters. However, this inherent durability is only fully realized through diligent upkeep and a thorough understanding of its operational parameters. Proactive maintenance not only prevents catastrophic failures but also optimizes performance, ensuring the heavy duty soft starter operates efficiently. In other words, investing time in understanding fault codes and commissioning parameters translates directly to fewer emergency calls and a more predictable production environment, contributing to goals discussed by the IEA: Driving Energy Efficiency in Heavy Industries regarding industrial efficiency.

In conclusion, the Benshaw MX4PB is more than just a motor starter; it is a critical component for safeguarding the entire electromechanical system. Effectively managing the electrical stresses associated with motor startup, such as the inrush currents that can cause voltage dips described by Journal of Engineering Research and Reports, is its primary advantage. Therefore, a well-maintained MX4PB soft starter is an indispensable tool for any facility focused on maximizing uptime, improving safety, and achieving long-term operational excellence. Adhering to the best practices outlined here will empower your team to maintain reliable and efficient motor control systems for years to come.

Read The Full Benshaw MX4PB Softstarters Research:

The Full Benshaw Mx4Pb Softstarters ResearchDownload

Facility Location:

1508 W 6th St Mishawaka, IN 46544

Free Ground Shipping on Motors, Drives And Softstarters Over $350

*Cart total must exceed $350 before taxes. Some product exclusions may apply, discount is applied automatically in the cart during checkout. For remote ‘limited access’ or Residential addresses that require special lift gate services, additional fees may apply. Please specify special shipping circumstances to avoid or limit these charges.

Certifications:

Payment Option Certifications

BBB Rating Certification



Snell Group Certification

Vibration Institute Certification

Categories

  • ABB ACS355
  • ABB Drives
  • AC Motor Speed Controllers
  • AC Tech SMVector
  • Accessories & Options
  • Articles
  • Automation & Control Systems
  • EATON SVX9000
  • Electric Motors
  • FAQ Automation
  • FAQ Electronics
  • FAQ Mechanical
  • FAQ Motor Shop
  • FAQ VFDs
  • FAQs
  • Field Experiences
  • How-To
  • HT SMVector VFD
  • HT VFDs
  • Industrial
  • Machine Shop Videos
  • News
  • Phase Converters
  • Power-Quality Components
  • Product Manuals
  • Repair & Field Services
  • Sensors & Feedback Devices
  • Service Offerings
  • Servo Drives & Motion Control
  • Servo Motors
  • Servo Motors
  • SMVector Drives
  • SMVector Series
  • Soft Starters & Motor Starters
  • Training Videos
  • Tutorials
  • Uncategorized
  • Variable Frequency Drives (VFDs)
  • Video Series

From The Blog:

  • 3 Phase Motor and VFD: Step-by-Step Wiring Guide
  • Siemens VFD Drives: A Beginner’s Selection Guide
  • Powerflex 755: Troubleshooting Common Fault Codes Guide
  • PCB Repair Services: A Guide to Industrial Board Repair
  • VFD Electric Motor: Specs, Setup, Standards & Best Practices
© Copyright - Precision Electric, Inc.
  • Link to X
  • Link to Facebook
  • Link to Youtube
  • Link to LinkedIn
Link to: MX4PB-HD-075-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology | 75.0 HP @ 480V | Max Current: 96.0 Amps Link to: MX4PB-HD-075-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology | 75.0 HP @ 480V | Max Current: 96.0 Amps MX4PB-HD-075-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters...
On Sale
Sale!
%
Off
16
Save $1,050
1050$
16%
1050
$
NEW, FACTORY SEALED!
Link to: MX4PB-HD-150-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology | 150.0 HP @ 480V | Max Current: 180.0 Amps Link to: MX4PB-HD-150-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters with Run Duty Bypass Non-Combination Starters with EMX4i Technology | 150.0 HP @ 480V | Max Current: 180.0 Amps
On Sale
Sale!
%
Off
16
Save $1,276
1276$
16%
1276
$
NEW, FACTORY SEALED!
MX4PB-HD-150-4-4-NC – Benshaw MX4PB Heavy Duty / Prepackaged Starters...
Scroll to top Scroll to top Scroll to top