Free Shipping on Motors Over $350!
Precision Electric, Inc.
A Family Owned
Small Business
USA Icon
Welcome, register
or login

Login

Forgot Password?
New to Precision Electric?

Register

A link to set a new password will be sent to your email address.

Have an account with Precision Electric?
Tracking
& Orders
Shop Or Ask Questions By Phone
574-256-1000
  • 0 Cart Icon
    Shopping Cart
  • Login/Register
  • Drives
    • AC Variable Frequency Drives
    • DC Variable Speed Drives
    • Need A Drive Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Softstarters
    • AC Motor Softstarters
    • Need A Softstarter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Phase Converters
    • Rotary Phase Converters
    • VFD Phase Converters For Motors
    • Need A Phase Converter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Motors
    • AC Motors
    • Need A Motor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Reactors
    • Input Line Reactors
    • Output Load Reactors
    • Need A Reactor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Filters
    • Input EMC Filters
    • Input Harmonic Line Filters
    • Output dv/dt Filters
    • Output Sinewave Filters
    • Need A Filter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Free Repair Quotes
    • Ready To Send An Item? Click Here To Get A Packing Slip For A Free Quote
    • AC Drive Repair
    • AC Motor Repair
    • DC Drive Repair
    • DC Motor Repair
    • Servo Drive Repair
    • Pump Repair
    • PCB Repair
    • Servo Motor Repair
    • Other Electronics Repair
  • On-Site Service
    • AC / DC Drives
    • AC / DC Servo Drives
    • AC / DC Servo Motors
    • AC / DC Motors
    • Computers & PCs
    • Pumps
    • Electronics & PCBs
    • Automation Systems
    • System Retrofits
    • Systems Integration
    • Preventive Maintenance
    • Vibration Analysis
    • Infrared Thermography
    • Energy Savings
  • Support
    • Call 574-256-1000
    • Contact Us
    • About
    • Product Manuals
    • Technical Blog
    • Baldor / ABB IEC And NEMA Motor Frame / Motor Size Reference Charts
    • Submit A Support Ticket
    • Request Product Return Authorization
    • Request Product Warranty Authorization
    • Request An Open Account
  • VFD Training Videos
  • Menu Menu
Wire Transfer Logo EASA Logo Free Shipping on Orders Over $350 Logo EASA Accreditation Logo AEGIS Partner Logo EASA Accreditation Logo SSL Secure Logo
Eaton S611 Series Solid-State Reduced Voltage Pump Control 3 Phase Softstarter | 250.0 HP @ 480V | Max Current: 302.0 Amps | Control Voltage: 24 VDC - S611E302P3S-480V
Eaton S611 Series Solid-State Reduced Voltage Pump Control 3 Phase Softstarter | 250.0 HP @ 480V | Max Current: 302.0 Amps | Control Voltage: 24 VDC - S611E302P3S-480V - Image 2
NEW, FACTORY SEALED!

Prices Include:

  • FREE Ground Shipping On Drives And Softstarters

    Storewide On All Drives And Softstarters Over $350*

  • Unlimited US Based Phone Support

    Contact Us Any Time At 1-574-256-1000.

  • Access To Our Team Of Engineers

    Trust Our Over 100 Years Combined Industry Experience

  • American Small Business

    Family Owned And Operated Customer Service Since 1983.

  • Hassle Free Warranty Claims

    We Help Process Warranty Replacement & Repair Claims.

Eaton S611 Series Solid-State Reduced Voltage Pump Control 3 Phase Softstarter | 250.0 HP @ 480V | Max Current: 302.0 Amps | Control Voltage: 24 VDC – S611E302P3S-480V

$ 25631 08

4 In Stock - Order Soon!

Quantity: 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
View Cart

Send Enquiry for Eaton S611 Series Solid-State Reduced Voltage Pump Control 3 Phase Softstarter | 250.0 HP @ 480V | Max Current: 302.0 Amps | Control Voltage: 24 VDC – S611E302P3S-480V

Unauthorized enquiry
Enquiry email sent successfully!

Need Member, Reseller, or OEM Pricing?

Register or Login

Estimated Repair Price: $7,689.32 - $17,941.76

Request a Repair Quote
  • Specifications
  • Overview
  • Manuals

Product Specifications

ManufacturerEaton
SeriesS611 Series
Model #S611E302P3S-480V
Horsepower250.0 HP
Input Voltage(s):400 - 480 VAC Input,
Output Voltage(s):480 VAC Output
Rated Current:302.0 Amps
Input Phase:Three Phase Input
Output Phase:Three Phase Output
Enclosure:Not Rated
Height31 in
Width18 in
Depth10 in
Weight86 lbs
Learn MoreYou can hover your mouse over highlighted product specs to learn more.

Description

Estimated reading time: 13 minutes

Introduction to Eaton S611 Softstarters for Motor Control

When managing industrial AC motor applications, controlling the initial startup is critical for protecting both the motor and connected mechanical systems. The eaton S611 softstarters are specifically designed to address this challenge by providing a smooth, stepless acceleration. Unlike traditional across-the-line starters that cause significant electrical and mechanical shock, the S611 gradually applies voltage to the motor. Consequently, this controlled start significantly reduces inrush current and minimizes wear on belts, gears, and couplings. According to S611 Soft Starter User Manual, this reduction in mechanical stress can dramatically extend the life of system components, making the S611 an essential upgrade for applications ranging from pumps and fans to conveyors and compressors.

Eaton S611 Softstarter Design & Protection

The S611 series from Eaton Corporation stands out due to its compact design and comprehensive feature set. A key advantage is the inclusion of built-in bypass contactors, which, as noted by Kjelectric, greatly reduce heat generation and increase efficiency once the motor reaches full speed. Furthermore, the S611 offers advanced motor protection features, including electronic overload protection with adjustable trip classes, phase loss, and shorted load detection. This integration of starting and protection capabilities into a single unit, a feature highlighted by Wistexllc, simplifies the overall control panel design and wiring. For instance, users can select between a voltage ramp or a current limit start mode to precisely match the starting profile to the specific application requirements.

While a Variable Frequency Drive (HTTP Request-guide-industrial-efficiency/">VFD) offers complete speed control, it is often overly complex and expensive for applications that only require controlled starting and stopping. In other words, the S611 soft starter fills a crucial gap by providing a cost-effective alternative for fixed-speed applications. It delivers the necessary protection against electrical and mechanical stress without the added cost of continuous speed regulation. An Eaton datasheet emphasizes that this device is engineered to control acceleration and deceleration, making it ideal for improving system performance and longevity. Ultimately, for facility managers and engineers looking to enhance motor reliability and reduce peak energy demand during startup, the S611 presents a highly practical and efficient solution.

What Is a Soft Starter and How Does IT Work?

An AC motor, when started directly across the line, experiences a significant inrush of current and mechanical shock, which can cause damage over time. To solve this, devices like Eaton s611 softstarters are employed to protect the motor and connected equipment. A soft starter is a solid-state device that manages the voltage supplied to an AC motor during its startup phase. In essence, it provides a gentle ramp-up to full speed, which is a stark contrast to the abrupt power delivery of a traditional contactor. This controlled start is crucial for reducing electrical and mechanical stress, thereby extending the life of the entire system. According to Wistex S611F414N3S 414 Amp, this technology integrates motor starting and overload protection into a single, efficient unit.

Eaton S611 Soft Starter Operating Principles

The core of a soft starter's operation involves devices called Silicon Controlled Rectifiers (SCRs), which are a type of thyristor. As noted by Eaton S611 Catalog Pages, a soft starter uses these SCRs to temporarily limit the voltage and, consequently, the current delivered to the motor's windings. By precisely controlling the firing angle of the SCRs, the device gradually increases the voltage from an initial set point to the full line voltage over a configurable period. This smooth ramp-up prevents the electrical and mechanical stresses associated with direct-on-line starts. Once the motor reaches full speed, an internal bypass contactor often closes, allowing the current to flow directly to the motor and increasing thermal efficiency.

Ultimately, the primary benefit of an Eaton motor starter is the significant reduction in wear and tear on mechanical components like gears, belts, and couplings. This controlled acceleration minimizes sudden torque spikes, which can be particularly damaging in applications such as conveyor systems or pumps. For instance, S611 Soft Starter User Manual highlights that mitigating this stress can extend the life of bearings and other components by two to six times. While a Variable Frequency Drive (VFD) can also control motor startup, a soft starter is a more cost-effective solution specifically designed for applications where speed control during operation is not required.

Front view of the Eaton S611 softstarters unit, showcasing its compact design for industrial AC motor control applications.

The Eaton S611 softstarter provides a reliable and compact solution for reducing mechanical shock and electrical stress during motor startup.

Key Features and Specifications of Eaton S611 Softstarters

The Eaton s611 softstarters stand out due to a robust set of features designed for optimal control and protection of AC motors. A primary characteristic is their flexible starting methods; operators can choose between a voltage ramp or a current limit start mode to match specific application demands, a detail confirmed by sources like Rexelusa. In addition, these units offer variable ramp times from 1 to 120 seconds, allowing for precise control over motor acceleration and deceleration. This level of control is essential for reducing mechanical stress on equipment and minimizing electrical disturbances like inrush currents on the power system. Consequently, the S611 series helps extend the life of connected machinery and improves overall system reliability.

A significant advantage of the soft starter S611 is its integrated design. As noted in the Eaton S611 Soft Starter PDF datasheet, the S611 includes built-in run bypass contactors, which improve thermal performance and efficiency by minimizing heat dissipation during continuous operation. Furthermore, the device provides comprehensive motor protection with adjustable electronic overload settings from Class 5 to 30, safeguarding against overcurrent, phase loss, and other fault conditions. According to Eaton S611 Catalog Pages, this advanced protection reduces nuisance trips. The user-friendly interface, featuring an LED display and keypad, simplifies setup and provides access to critical diagnostics, as highlighted by Indratel S611 Soft Starter, making it a highly serviceable and efficient motor control solution.

Proper Wiring and Installation Based on the Eaton S611 Manual

A successful S611 soft starter setup hinges on meticulous wiring and installation, strictly following the official S611 Soft Starter User Manual S611 manual. Before beginning any work, it is imperative to implement stringent Lockout/Tagout (LOTO) procedures to de-energize the circuit, ensuring compliance with NFPA 70E safety standards. Proper installation not only guarantees the reliable operation of the AC motor but also prevents electrical hazards and premature equipment failure. Consequently, all wiring must conform to the National Electrical Code (NEC) and any local regulations, paying close attention to conductor sizing, overcurrent protection, and grounding requirements for the specific motor and starter combination.

Eaton S611 Wiring Diagram & Connections

Executing the connections requires careful attention to the S611 wiring diagram. The three-phase AC input power should be connected to the L1, L2, and L3 terminals, while the motor leads connect to the T1, T2, and T3 load terminals. According to documentation from sources like Eaton S611 Catalog Pages, it is crucial to verify the control voltage (typically 120V AC) and connect it to the designated control power terminals. Furthermore, ensure all connections are torqued to the manufacturer’s specifications to prevent hot spots and intermittent failures. Miswiring the line and load connections is a common error that can cause immediate damage to the soft starter’s internal SCRs upon startup.

Beyond the electrical connections, the physical installation is equally important for the longevity of Eaton S611 softstarters. The unit must be mounted securely in a vertical orientation inside an enclosure that provides adequate ventilation to dissipate heat effectively. As detailed by suppliers like Wistex S611F414N3S, maintaining the specified ambient operating temperature and ensuring sufficient clearance around the device prevents overheating and nuisance tripping. In other words, proper spacing allows for natural convective cooling, which is essential because the S611 has built-in bypass contactors that still generate some heat during operation. A dedicated and properly sized equipment grounding conductor is non-negotiable for safety and proper operation.

A Practical Guide to S611 Soft Starter Setup and Commissioning

Diagram illustrating how Eaton S611 softstarters provide a smooth voltage ramp-up to protect AC motors from high inrush cu...

A soft starter, like the Eaton S611, prevents electrical and mechanical stress by gradually increasing voltage to the motor, ensuring a smooth, controlled start instead of a sudden, damaging power surge.

Proper S611 soft starter setup is a critical step that ensures both equipment longevity and operational reliability for your AC motor. Fortunately, Eaton designed the S611’s user interface for fast setup and commissioning, making the process straightforward for qualified personnel. The initial configuration involves setting fundamental parameters based on your motor and load characteristics, such as the start mode, ramp times, and the motor’s full load current (FLA). Getting these initial settings correct is paramount for protecting the mechanical components of your system from excessive stress during startup. Consequently, a methodical approach to programming prevents future operational issues and nuisance trips.

Before applying power to the unit, it is absolutely essential to follow all mandated safety protocols, including stringent Lockout/Tagout (LOTO) procedures compliant with NFPA 70E. First, verify that all power and control wiring matches the official S611 wiring diagram provided in the Eaton S611 manual. Following this, double-check the motor nameplate data against the parameters you intend to program into the soft starter. An incorrect FLA setting, for instance, can lead to inadequate motor protection or nuisance tripping. This verification step is a non-negotiable part of a professional commissioning process that guarantees both safety and performance.

Configure Eaton S611 Start Mode: Voltage or Current

During programming, a key decision is selecting the appropriate start mode. The S611 allows you to choose either a voltage ramp or a current limit start, as noted by Eaton S611 Series Softstarter. A voltage ramp provides a smooth, linear increase in voltage, which is ideal for general-purpose loads. In contrast, a current limit start is crucial for applications where you must adhere to strict inrush current limitations imposed by power utilities or local codes, a scenario Eaton S611 Soft Starter Data Sheet highlights. In addition, you must also configure the appropriate overload protection by selecting an adjustable trip class (from 5 to 30) to precisely match the motor’s thermal capacity, a feature detailed by Eaton Controls S611 Catalog.

Once the initial parameters are programmed, the commissioning test can begin. It is best practice to first perform a test run with the motor disconnected from the load to verify correct rotation and listen for any unusual noises. After that, connect the load and initiate a start sequence while carefully observing the motor's acceleration. For high-friction or heavy inertia loads, the "kick-start" feature can provide a brief voltage boost to overcome initial static forces, a useful function described in the S611 Soft Starter User Manual user manual. If the start is too aggressive or too slow, you can then make fine adjustments to the ramp time and initial torque settings to achieve a perfectly smooth and controlled acceleration profile for your specific application.

Common Eaton S611 Troubleshooting Scenarios

Even with robust equipment like eaton S611 softstarters, operational issues can arise. Effective Eaton S611 troubleshooting begins with a systematic approach, leveraging the device's built-in diagnostics. Before addressing any fault, it is crucial to observe all safety protocols, including proper Lockout/Tagout (LOTO) procedures, to de-energize the equipment. According to Eaton S611 Soft Starter PDF, the user interface is specifically designed for fast setup and easy troubleshooting, making it a valuable starting point for any diagnostic effort.

One of the most common issues involves the AC Motor failing to start or tripping during ramp-up. This can often be traced back to incorrect parameter settings. For instance, the start mode may not be appropriate for the connected load. The S611 allows operators to choose between a voltage ramp or a current limit start mode, as noted by Eaton S611 Series Softstarter. An incorrect selection or improperly set ramp time can lead to insufficient torque. Consequently, you should carefully review the application's requirements and adjust the startup profile in the soft starter’s settings to match the load characteristics.

Interpreting S611 fault codes is another critical aspect of diagnostics. The device records a history of trips, which provides valuable clues about the root cause of a problem. The user interface allows technicians to view parameters and access the fault queue, as detailed by Eaton S611 Catalog. For example, recurring overcurrent or phase loss faults might indicate issues with the power supply, motor windings, or mechanical binding in the driven load. In addition, problems with external control wiring or network communications can also prevent operation, making it essential to verify all connections. For more advanced systems, it's worth noting the S611 has extensive communication capabilities that, as Eaton Controls S611 Catalog mentions, can be monitored for faults.

Front view of the Eaton S611 softstarters unit, highlighting its digital display, control interface, and key specification...

The Eaton S611 softstarters series features a compact design with an easy-to-read display, simplifying setup and monitoring for optimal motor control and protection in industrial applications.

Decoding and Resolving S611 Fault Codes

Effective Eaton S611 troubleshooting hinges on correctly interpreting its diagnostic system. According to Eaton Controls S611 Catalog, the S611 features an easy-to-use interface that provides access to the fault queue, which is a crucial first step in diagnosing operational issues. This built-in capability simplifies identifying the root cause of a trip, consequently minimizing downtime and streamlining maintenance efforts. Understanding these S611 fault codes is essential for any technician responsible for the reliability of AC motor systems.

For instance, one of the most frequent alerts is an Overload (OLF) fault, which indicates the motor has exceeded its current limit for a set duration. This could be due to mechanical binding or an incorrect setting of the adjustable trip classes. Other common faults include Phase Loss (PH Flt), which points to a lost input or output phase, and Overvoltage (OV Flt) or Undervoltage (UV Flt), signaling power supply issues. The Eaton S611 Soft Starter Manual user manual provides a comprehensive list of these codes and their specific meanings. Each fault points to a distinct problem, thereby guiding the diagnostic process.

Before beginning any diagnostic work, always adhere to strict Lockout/Tagout (LOTO) procedures to ensure the system is de-energized and safe. Once the equipment is secure, you can access the fault log through the keypad to identify the most recent trip. The user interface is designed for fast setup and easy troubleshooting, as noted by Eaton S611 Soft Starter Brochure. After identifying the code, consult the official Eaton S611 manual for recommended corrective actions, such as inspecting wiring, verifying the motor load, or checking supply voltage. Finally, systematically resolving the issue ensures the long-term health of both the motor and the soft starter.

Preventive Maintenance for Your Eaton Motor Starter

To ensure the long-term reliability of your Eaton motor starter, a consistent preventive maintenance schedule is essential. This proactive approach significantly reduces the risk of unexpected downtime and helps extend the equipment's operational life. Before beginning any work, always adhere to strict Lockout/Tagout (LOTO) procedures to ensure the system is fully de-energized. Subsequently, perform a thorough visual inspection for any signs of physical damage or debris, and use compressed air to clean the unit's heatsink and ventilation ports. As noted by Eaton, preventing overheating is critical for component longevity.

The next step involves inspecting all electrical connections for tightness, as thermal cycling can cause them to loosen over time. Therefore, periodically verify that power and control terminals are torqued to the specifications listed in the Eaton S611 manual. In addition to physical checks, leveraging the S611’s diagnostic features offers a powerful preventive strategy. The device allows you to monitor and log key operating parameters, which, according to Eaton S611 Catalog Pages, is fundamental for effective system management. Regularly reviewing metrics like motor current and thermal capacity helps identify trends that signal developing issues with the AC motor or its load. This data-driven approach allows for scheduled interventions instead of costly emergency repairs, increasing the service life of your entire system as explained by S611 Soft Starter Details.

Conclusion: Maximizing Reliability with Your Eaton S611

Ultimately, the Eaton S611 softstarters represent a critical component for enhancing AC motor longevity and overall system efficiency. This article has guided you through the entire lifecycle, from proper installation and wiring to advanced S611 soft starter setup and troubleshooting common fault codes. As detailed by sources like Eaton Controls S611 Catalog, features such as internal bypass contactors significantly reduce heat generation, thereby improving the device's operational lifespan and reliability. Mastering these aspects ensures you get the most out of your motor control system from day one.

To truly capitalize on this investment, however, it is essential to adhere to the preventive maintenance schedules outlined in the Eaton S611 manual. Diligent monitoring and proactive servicing ensure your Eaton motor starter operates within its specified parameters, preventing unplanned downtime. Consequently, this proactive approach directly contributes to reduced mechanical wear on all connected equipment. According to Eaton S611 Soft Starter, this reduction in physical stress significantly extends the life of everything from bearings to gearboxes.

In conclusion, by integrating the advanced capabilities of the S611 with disciplined operational practices, you establish a foundation for a truly resilient and efficient system. The initial investment, which can be explored on sites like Wistexllc, pays dividends through decreased maintenance costs and enhanced productivity. For instance, the ability to control acceleration and deceleration smoothly protects against issues like water hammer, a key benefit highlighted by Eaton. Therefore, mastering your S611 is a direct investment in your facility's long-term operational excellence.

Read The Full Eaton S611 Softstarters Research:

The Full Eaton S611 Softstarters ResearchDownload

 

 

S611 Series Technical Manuals

Product Manuals

  • S611-Soft-Starter-User-Manual (1.58 MB)
  • Enclosed S611 Stock List (166 KB)
  • IL for Modbus Module for C440, S611, S811+ and as Stand-Alone IO (426 KB)
  • IL for PROFIBUS Module for C440, S611, S811+ and as Stand-Alone IO (237 KB)

Communication Manuals

  • C441-DeviceNet-Module-User-Manual (1.05 MB)
  • C441-Profibus-Module-User-Manual (2.78 MB)

Catalogs & Brochures

  • S611 Soft Starter (2.03 MB)
  • Enclosed S611 Solid-State Soft Starter (435 KB)
  • Motor Control Made Easy - Quick Ship Program (280 KB)
  • Packaged Control Solutions (1.15 MB)
  • Solid-State Motor Control Catalog (2.34 MB)
  • C411 Communication Modules and Accessories for Electronic Overload Relays and Soft Starters (730 KB)
  • Enclosed Reduced Voltage Starters Catalog (970 KB)
  • Enclosed-Control-Reference-Guide (3.19 MB)
  • Industrial Controls Line Card (10.38 MB)
  • Irrigation Pump Panels Three-Phase Control Quick Ship Inventory (194 KB)
  • Low Voltage Motor Starters and Contactors Consulting Application Guide (10.63 MB)

CAD Drawings

  • S611 Soft Starter Frame A-B 10-9807 (273 KB)
  • S611 Soft Starter Frame C-D 10-9808 (446 KB)
  • S611 Soft Starter Frame E-F 10-9809 (291 KB)

Facility Location:

1508 W 6th St Mishawaka, IN 46544

Free Ground Shipping on Motors, Drives And Softstarters Over $350

*Cart total must exceed $350 before taxes. Some product exclusions may apply, discount is applied automatically in the cart during checkout. For remote ‘limited access’ or Residential addresses that require special lift gate services, additional fees may apply. Please specify special shipping circumstances to avoid or limit these charges.

Certifications:

Payment Option Certifications

BBB Rating Certification



Snell Group Certification

Vibration Institute Certification

Categories

  • ABB ACS355
  • ABB Drives
  • AC Motor Speed Controllers
  • AC Tech SMVector
  • Accessories & Options
  • Articles
  • Automation & Control Systems
  • EATON SVX9000
  • Electric Motors
  • FAQ Automation
  • FAQ Electronics
  • FAQ Mechanical
  • FAQ Motor Shop
  • FAQ VFDs
  • FAQs
  • Field Experiences
  • How-To
  • HT SMVector VFD
  • HT VFDs
  • Industrial
  • Machine Shop Videos
  • News
  • Phase Converters
  • Power-Quality Components
  • Product Manuals
  • Repair & Field Services
  • Sensors & Feedback Devices
  • Service Offerings
  • Servo Drives & Motion Control
  • Servo Motors
  • Servo Motors
  • SMVector Drives
  • SMVector Series
  • Soft Starters & Motor Starters
  • Training Videos
  • Tutorials
  • Uncategorized
  • Variable Frequency Drives (VFDs)
  • Video Series

From The Blog:

  • 3 Phase Motor with VFD: A Beginner’s Wiring Guide
  • VFD 3 Phase Motor: How To Wire Step-by-Step Guide
  • 3 Phase Motor VFD: A Guide to Choosing the Right One
  • 3 Phase Motor and VFD: Step-by-Step Wiring Guide
  • Siemens VFD Drives: A Beginner’s Selection Guide
© Copyright - Precision Electric, Inc.
  • Link to X
  • Link to Facebook
  • Link to Youtube
  • Link to LinkedIn
Link to: ABB IP00 PSTX Series Solid-State Reduced Voltage 3 Phase Softstarter | 62.5 HP @ 600V | Max Current: 68.0 Amps | Control Voltage: 100 – 240 VAC – PSTX72-600-70-600V Link to: ABB IP00 PSTX Series Solid-State Reduced Voltage 3 Phase Softstarter | 62.5 HP @ 600V | Max Current: 68.0 Amps | Control Voltage: 100 – 240 VAC – PSTX72-600-70-600V ABB IP00 PSTX Series Solid-State Reduced Voltage 3 Phase Softstarter | 62.5...
NEW, FACTORY SEALED!
Link to: Eaton S611 Series Solid-State Reduced Voltage Pump Control 3 Phase Softstarter | 350.0 HP @ 600V | Max Current: 302.0 Amps | Control Voltage: 24 VDC – S611E302P3S-600V Link to: Eaton S611 Series Solid-State Reduced Voltage Pump Control 3 Phase Softstarter | 350.0 HP @ 600V | Max Current: 302.0 Amps | Control Voltage: 24 VDC – S611E302P3S-600V
NEW, FACTORY SEALED!
Eaton S611 Series Solid-State Reduced Voltage Pump Control 3 Phase Softstarter...
Scroll to top Scroll to top Scroll to top