RB2-1-S-027A-11C – Benshaw RB2 Open Chassis Softstarter | 10.0 HP @ 240V | 20.0 HP @ 480V | 25.0 HP @ 600V | Max Current: 27.0 Amps | Max Voltage: 600V | Control Voltage: 120 VAC
Discount
-16%$214241List: $2544.00
In Stock
Send Enquiry for RB2-1-S-027A-11C – Benshaw RB2 Open Chassis Softstarter | 10.0 HP @ 240V | 20.0 HP @ 480V | 25.0 HP @ 600V | Max Current: 27.0 Amps | Max Voltage: 600V | Control Voltage: 120 VAC
You can hover your mouse over highlighted product specs to learn more.
Description
Estimated reading time: 11 minutes
Introduction: Why Modern Motors Demand More Than an Across-the-line Start
In modern industrial settings, simply throwing a motor across the line is an outdated and often damaging practice. While effective for getting a motor spinning quickly, this direct-on-line approach creates a massive electrical and mechanical shock. For instance, an induction motor can draw an inrush current six to eight times its normal full-load rating, a surge that puts immense strain on the power supply. This is where advanced motor control solutions, such as a benshaw soft starter, become essential for protecting valuable assets. According to LSE Soft Starters, these high-current events can cause significant voltage dips across the electrical system, potentially disrupting other sensitive equipment.
The consequences of this abrupt start extend far beyond the electrical system. The sudden application of torque delivers a violent mechanical jolt to the entire powertrain, including gearboxes, couplings, belts, and the driven load itself. Over time, this repeated stress leads to premature wear, increased maintenance costs, and costly unplanned downtime. As explained by Machinedesign, high starting currents can damage not only the motor but also the connected mechanical components. In fluid-based systems like pumps, this jolt can even lead to dangerous phenomena like water hammer, which, as noted by Abb, can rattle pipes and cause significant system damage.
To address these challenges, modern facilities are turning to reduced voltage starter technology. Specifically, Benshaw RB2 softstarters offer a sophisticated method for controlling motor acceleration by gradually ramping up the voltage from an initial setpoint to the full line voltage. This controlled start significantly mitigates the electrical inrush current and eliminates the mechanical shock associated with across-the-line methods. Consequently, this leads to extended equipment life, reduced operational costs, and enhanced system reliability. By implementing an industrial motor starter like the RB2 Open Chassis Soft Starter RB2, engineers can ensure a smooth, gentle start that protects both the motor and the machinery it drives.
An Engineer's Look at Benshaw RB2 Softstarters Features
The engineering behind Benshaw RB2 softstarters centers on the advanced MX2 control technology, which provides a highly intuitive interface for sophisticated motor management. This built-in controller is the foundation of the unit's flexibility, allowing for precise configuration without overly complex programming. According to LV Solid-State Starters Catalog, the RB2 comes standard with a built-in keypad and display, which simplifies setup and real-time monitoring of operational parameters. Consequently, this design focus makes the RB2 motor control accessible for both initial commissioning and ongoing maintenance tasks in demanding industrial environments.
A key advantage of this industrial motor starter lies in its versatile starting and stopping capabilities. The controller offers multiple starting modes, including voltage ramp, current limit, and torque ramp, ensuring optimal performance across varied loads like pumps, fans, and conveyors. For instance, LV Solid-State Starters Catalog highlights that these modes are fully adjustable, allowing engineers to fine-tune the motor's acceleration curve to prevent mechanical shock and electrical disturbances. In addition, the unit features programmable deceleration modes, which are critical for applications like pumping to mitigate water hammer effects.
Beyond controlled starting, the Benshaw RB2 series integrates comprehensive motor protection, which is essential for asset longevity and operational safety. This reduced voltage starter is equipped with a suite of protective elements that safeguard the motor from a wide range of fault conditions. These include protections against phase loss, phase reversal, overcurrent, and current imbalance, as detailed in technical documentation from Benshaw. This robust, integrated approach to motor safety, praised by suppliers like Trimantec, ultimately reduces downtime and prevents costly equipment failures.
Unlike damaging across-the-line starts, Benshaw RB2 softstarters provide a controlled, reduced voltage ramp-up, protecting valuable motor assets.
Installation and Wiring Best Practices
Proper installation and wiring are fundamental to the long-term reliability of Benshaw RB2 softstarters. To begin with, all procedures must strictly adhere to the guidelines outlined in the Benshaw RB2 manual, as well as national and local standards like the NEC and NFPA 70E for electrical safety. Before any work commences, it is absolutely critical to perform a complete lockout/tagout of the motor control circuit to ensure technician safety. According to Soft Starters, a meticulous setup not only guarantees performance but also significantly extends the motor’s operational life. Consequently, overlooking these initial steps can lead to equipment failure, safety hazards, and costly downtime.
Mounting & Wiring Your Benshaw RB2 Soft Starter
When physically mounting the industrial motor starter, ensure it is installed in a clean, dry location with adequate ventilation to dissipate heat effectively. The starter should be housed in a NEMA-rated enclosure appropriate for the operating environment, whether that requires protection from dust, moisture, or corrosive elements. Furthermore, selecting the correct wire gauge for both line and load connections is crucial; undersized conductors can overheat and pose a significant fire risk. As detailed by RB2 Open Chassis Soft Starter, the RB2 chassis is designed for straightforward mounting in various panel configurations. Proper grounding through the provided lug is not optional—it is essential for both safety and mitigating electrical noise.
For the final connections, always maintain physical separation between power and control wiring to prevent electromagnetic interference (EMI), which can disrupt the sensitive electronics within the RB2 motor control. This means routing low-voltage control cables away from high-voltage power lines. In addition, all terminal connections should be torqued to the specifications listed in the installation guide to prevent loose connections, a common source of arcing and heat buildup. As ABB Softstarters notes, reducing electrical and mechanical stress from the start enhances the reliability of the entire system. For instance, correctly configuring the bypass contactor, if used, ensures the soft starter's SCRs are protected from continuous load current after the motor reaches full speed, as mentioned in documentation from Benshaw Manual RB2 RC2.
Step-by-step RB2 Soft Starter Setup and Parameterization
Proper RB2 soft starter setup is the foundation for reliable motor performance and longevity. Before applying power, always verify that all wiring conforms to the schematics and that appropriate lockout/tagout (LOTO) procedures are in effect. The initial commissioning of Benshaw RB2 softstarters is streamlined thanks to an intuitive user interface accessible via the built-in keypad. According to Benshaw LV SS Motor Control Brochure, the MX2 control technology is designed to be exceptionally easy to configure. Consequently, technicians can quickly navigate menus to input critical motor data and operational parameters, which significantly reduces downtime during installation or replacement. It is essential to have the motor nameplate data and the Benshaw RB2 manual on hand before you begin programming.
Benshaw RB2 Soft Starter Quick Setup
For most applications, the Quick Start Menu provides all the necessary fields to get a motor running safely. First, you must accurately enter the motor’s Full Load Amps (FLA) to ensure the overload protection is set correctly. Subsequently, you will configure the start and stop ramp times, which dictate how long the starter takes to accelerate the motor to full speed and decelerate it to a stop. For instance, a setting of 10 seconds is common for general-purpose conveyor belts. Another critical parameter is the initial start voltage (or torque), which should be adjusted just high enough to cause the motor to begin rotating immediately. Kentstore RB2-1-S-838A-20C notes that these basic settings are easily accessible, allowing for rapid commissioning.
Beyond basic setup, the Benshaw soft starter allows for advanced parameterization to optimize performance for specific loads. This includes selecting different starting modes, such as Voltage Ramp for simple loads or Current Limit for applications sensitive to high inrush currents. The official Benshaw brochure details several modes, including voltage ramp with current limit and torque ramp. Furthermore, parameters for deceleration control, dual ramp profiles, and specific protective functions can be fine-tuned. For a complete list of all programmable parameters and their descriptions, consulting the detailed Benshaw Manual for the RB2 is the recommended best practice to ensure all settings align with the application’s demands and NEC guidelines.
The advanced MX2 control technology is a core feature of Benshaw RB2 softstarters, giving engineers precise and reliable reduced voltage starting for critical applications.
Advanced Configuration of Your Benshaw Soft Starter
To truly optimize your system, the advanced configuration of your RB2 motor control goes beyond the basic setup. While the Quick Start menu is excellent for common applications, the underlying MX2 technology offers a suite of adjustable parameters for tailoring performance. For instance, you can fine-tune the motor's starting and stopping characteristics to precisely match demanding loads, which, as noted by experts at Soft Starters, significantly enhances operating efficiency and reliability. This level of control helps mitigate mechanical stress on couplings and gearboxes, ultimately extending the life of your equipment.
A key feature in the advanced settings is the ability to program dual ramp profiles. Consequently, this allows an operator to select between two distinct start/stop configurations, which is invaluable for applications with varying load conditions. For example, you can have one profile for a fully loaded conveyor and a second for an empty one. According to Benshaw LV SS Motor Control Brochure, the unit also features programmable deceleration modes, providing superior control over stopping to prevent issues like water hammer in pumping systems, a problem detailed by ABB Softstart Advisor. These adjustments ensure a smooth, controlled process from start to finish.
Furthermore, for system integration, the Benshaw RB2 softstarters come standard with Modbus RTU communication capabilities. This allows for seamless integration with PLCs, HMIs, and SCADA systems for remote monitoring and control. Technicians can access and modify parameters, monitor real-time data like current and voltage, and diagnose faults without opening the control cabinet, which aligns with modern safety protocols like NFPA 70E. The official Benshaw brochure details these extensive metering and communication options. This connectivity transforms the starter from a simple motor controller into an intelligent device within a larger automation ecosystem.
Troubleshooting Common Faults in Benshaw RB2 Softstarters
Even with their robust design, troubleshooting a Benshaw soft starter is a necessary skill for any technician. Thankfully, Benshaw RB2 softstarters come equipped with a comprehensive suite of diagnostic tools and fault codes designed to simplify the process. Before diving into any hands-on diagnostics, it is crucial to always consult the official Benshaw RB2 manual for detailed fault descriptions and recommended actions, as this documentation provides the most accurate guidance. According to industry experts at Machine Design, understanding these protective features is key to extending a motor’s life. Always begin by observing the fault code displayed on the keypad; consequently, this code is your primary indicator of the problem's origin.
Troubleshooting Benshaw RB2 Softstarter Faults
Common faults often relate to external power conditions or the connected load. For instance, a "Phase Loss" or "Phase Imbalance" fault typically points to an issue with the incoming three-phase power, not the RB2 motor control itself. Similarly, an "Overcurrent" fault suggests the motor is drawing more current than its rating, which could be due to a mechanical jam or a sudden increase in load. The Benshaw LV SS Motor Control Brochure documentation details dozens of such protective elements. In contrast, a "Shorted SCR" fault points to an internal component failure within the starter, which may require repair or replacement. A detailed fault code list can often be found in technical manuals available online through resources like Benshaw Manual RB2 RC2.
Before performing any physical inspection or component testing, strictly adhere to all lockout/tagout (LOTO) procedures as mandated by NFPA 70E to de-energize the equipment completely. Once the system is verified to be in a zero-energy state, you can proceed with checks such as verifying input voltage, inspecting terminal connections for tightness, and ensuring the motor windings are not shorted or grounded. For persistent issues without clear fault codes, reviewing the event log can provide a history of alarms that may reveal an intermittent problem. This careful, step-by-step process ensures both personal safety and effective resolution, confirming the starter's reputation as a rugged industrial controller, as noted by distributors like Trimantec.
Following best practices for installation and wiring is crucial for the long-term reliability of your Benshaw RB2 softstarters and motor protection.
Preventive Maintenance for Peak Industrial Motor Starter Performance
To ensure the long-term reliability of your Benshaw soft starter, a proactive preventive maintenance schedule is crucial. These reduced voltage starters benefit significantly from regular inspection, which helps prevent unexpected failures and costly downtime. Consistent maintenance is a cornerstone of efficient motor management, ensuring the gradual start-up continues to protect mechanical components from shock. As noted by experts at Soft Starters, this gentle acceleration reduces the immense strain of direct-on-line starts.
A vital first step involves a thorough visual inspection, always performed after following proper lockout/tagout procedures per NFPA 70E. Inside the enclosure, check for any accumulation of dust or debris, as contaminants can cause short circuits. Furthermore, you must ensure all ventilation fans and pathways are clear to facilitate proper cooling and prevent overheating. According to industrial best practices from ABB Softstarter Benefits, managing heat is critical to electronic component longevity. Lastly, carefully verify the tightness of all power and control wiring terminals, as vibrations and thermal cycling can cause them to loosen.
In addition to physical checks, regular electrical verifications are essential for maintaining your industrial motor starter. Periodically measure control power voltages to confirm they are within the specifications listed in the Benshaw RB2 manual. It is also good practice to inspect for any signs of discoloration on wiring or components, which could indicate overheating issues. These simple but effective steps serve as an early warning system, allowing for corrective action before a catastrophic failure occurs. As a leading manufacturer, RB2 Open Chassis Soft Starter builds durable equipment, but proactive care is key to maximizing its service life.
Conclusion: Mastering Your Benshaw Motor Controller for Long-term Reliability
Ultimately, mastering your Benshaw motor controller transforms it from a simple component into a cornerstone of operational reliability. Throughout this guide, we have explored the critical steps from initial installation to advanced parameterization, moving beyond basic across-the-line methods to protect valuable motor assets. According to Soft Starters, this gradual acceleration significantly reduces mechanical and electrical stress. This approach is fundamental to enhancing system longevity.
Consequently, the long-term benefits of a properly managed reduced voltage starter cannot be overstated. Diligent application of setup best practices, consistent preventive maintenance, and proactive troubleshooting are essential for peak performance. For instance, major manufacturers like Abb confirm that reducing inrush current prevents excessive wear on the motor and connected machinery. Therefore, consistent attention to your Benshaw RB2 softstarters is critical, as these units act as a protective gateway, a point highlighted by Benshaw.
In conclusion, the knowledge and procedures detailed here provide a comprehensive framework for managing your industrial motor starter. Always reference official documentation, like the resources from Benshaw LV SS Motor Control Brochure, and adhere to NEC and NFPA 70E safety standards to maintain a safe and reliable operation. Ultimately, your facility’s success depends on its core components, and a well-mastered RB2 is a key contributor to that stability.