SVX9000 Eaton Drive Guide: Ratings, Models and Catalog Numbers

Isometric illustration of an open gray metal enclosure holding an orange-and-white drive unit, terminal blocks, and a coiled

If you search for an svx9000 eaton drive, you probably need to confirm a catalog number, a rating or a replacement path before you buy. This guide explains what the drive is, how to read its catalog number, and where each model fits. It also covers what to check before you order.

On this page

What the SVX9000 Eaton drive is

What is the Eaton SVX9000 VFD?

The Eaton SVX9000 VFD is a general-purpose AC variable frequency drive from the Eaton (formerly Cutler-Hammer) 9000X family. In short, a VFD changes motor speed by changing the output frequency and voltage. This drive uses V/Hz control and open-loop sensorless vector control, which means it controls the motor without an encoder.

Also, Eaton describes the series as an all-purpose drive for standard machine, building and industrial uses. It lists peak torque up to 200%, a built-in 3% line reactor and an integrated help function. For example, typical jobs are pumps, fans and conveyors.

What is the difference between SVX9000, SVX 9000 and the 9000X?

First, people use these names loosely. The Eaton SVX 9000, the SVX9000 and the “SVX” all point to the same drive. However, the 9000X is the wider family, and it also includes the SPX9000.

Because of that, one document covers both drives. Eaton’s 9000X VFD user manual (MN04001004E) covers the SVX9000 and the SPX9000. The SVX9000 Eaton drive does not have closed-loop control, so ignore those sections if you own an SVX.

Is the Eaton SVX9000 discontinued or still available?

It depends on the exact catalog number. Eaton’s own SKU pages mark many SVX numbers as discontinued or to be discontinued. For example, the SVX003A1-5A4N2 shows as discontinued.

As a result, most buying today supports drives already installed. Next, check each catalog number’s status on Eaton’s site, or contact Precision Electric to confirm what we can supply or repair.

For the right document, start with Eaton’s SVX9000 product page. It lists manuals, release notes and firmware.

SVX9000 models, ratings and frame sizes

What voltage and horsepower ranges does the SVX9000 come in?

The 9000X user manual covers 208-240 V and 380-500 V drives in NEMA 1/IP21 and NEMA 12/IP54. However, larger drives and 525-690 V drives appear in the catalogs. In addition, our listings include 600 V drives.

Isometric illustration of three navy-and-white cabinets of different heights, one with an orange panel, beside a stack of
Note the tallest enclosure’s frame size, which differs from the shorter units.

The ranges differ by catalog edition, so quote them with care:

  • 2006 catalog: 208 V and 230 V from 3/4 to 100 hp IH (1 to 100 hp IL). At 480 V, 1 to 1900 hp IH (1-1/2 to 2200 hp IL).
  • 2012 volume: 480 V from 1 to 1600 hp CT (1-1/2 to 1800 hp VT).

Enclosed NEMA 1 and NEMA 12 drives come in frames FR4 to FR9. Frames FR10 and larger are open chassis, though NEMA 1 and 12 are also available in the FR10 design.

What are the IH and IL ratings on an SVX9000?

First, Eaton rates each drive two ways. IH allows 150% overload and suits constant torque loads. In contrast, IL allows 110% overload and suits variable torque loads such as fans and pumps. Some Eaton documents label these CT and VT.

Current for IH is rated 100% at 50 C (122 F). IL is rated at 40 C (104 F) for FR9 and below. So always ask which rating a listing uses.

Here is a real example. Eaton’s 208-240 V table shows the FR9 SVX075A2-2A1N1 as 75 hp IH at 205 A and 100 hp IL at 261 A. By contrast, Eaton’s catalog lists the SVX100A1-2A1N1 and SVX100A2-2A1N1 as 100 hp IH at 261 A, with 125 hp IL at 300 A.

Why does a 100 HP SVX9000 Eaton drive show 261 A at 240 V but 140 A at 480 V?

For the same power, current rises as voltage falls. So half the voltage means about twice the current. At 480 V, the SVX100A1-4A1N1 is 100 hp IH at 140 A, and its IL rating is 125 hp at 170 A. Both the 261 A and 140 A figures are on the same IH basis, so the difference is mostly voltage. Still, compare hp, voltage and rating basis together, and never use a single hp-to-amp number alone.

What frame size is a 100 HP SVX9000?

A 100 hp, 480 V drive such as the SVX100A1-4A1N1 is frame FR8. Frame matters because it sets the mounting footprint, the terminal size and the cable lug fit. For that reason, check the frame before you swap a drive into an existing panel. Take the frame’s dimensions, weight and mounting clearances from the 9000X user manual rather than from a listing.

Common SVX9000 Eaton specs

  • Output voltage 0 to Vin; output frequency 0 to 320 Hz.
  • Input voltage +10%/-15%, at 50/60 Hz.
  • Maximum short-circuit rating of 100 kA rms, and UL 508C listing.
  • Integrated 3% line reactor on FR4 through FR9.
  • Switching frequency of 1 to 16 kHz on frames 4-6 (default 10 kHz), and 1 to 10 kHz on frames 7-12 (default 3.6 kHz).
  • Ambient range of -10 to +50 C without derating.

Precision SVX9000 models at a glance

Catalog numberHPVoltage classAmpsEnclosureBrake letter
SVX100A1-2A1N1100208-240 V261NEMA 1N
SVX100A2-2A1N1100208-240 V261NEMA 12N
SVX100A1-4A1N1100400-480 V140NEMA 1N
SVX100A2-4A1N1100400-480 V140NEMA 12N
SVX100A1-4A1B1100400-480 V140NEMA 1B
SVX100A1-5A4N1100540-600 V100NEMA 1N
SVX100A2-5A4N1100540-600 V100NEMA 12N
SVX010A2-2A1B110208-240 V31NEMA 12B

For the full rating tables, use the Eaton SVX9000 product series catalog (CA08100007E) hosted by Precision, or the June 2006 catalog (CA04000006E).

How to read an SVX9000 catalog number

How do I decode an SVX9000 catalog number?

Take SVX100A1-4A1N1 and read it from left to right:

  1. SVX: the product family.
  2. 100: the hp code.
  3. A: standard software.
  4. 1: the enclosure. 0 is open chassis, 1 is NEMA 1, and 2 is NEMA 12.
  5. 4: the 380-500 V class. Our 240 V listings show 2 here.
  6. A: the keypad code, where A means alphanumeric.
  7. 1: the expansion-board code, where 1 means standard boards (A9/A2).
  8. N: the brake letter.
  9. 1: the coating option, where 1 is standard and 2 is conformal (varnished) coating.

Our 600 V listings show 5A4 in this spot. However, we do not decode that code here, so check Eaton’s key for it.

What does the N or B at the end of an SVX9000 catalog number mean?

In Eaton’s key, N means no brake chopper and B means an internal brake chopper. Also, a brake chopper sends extra motor energy to a braking resistor during fast stops. So the SVX100A1-4A1B1 adds that circuit to the SVX100A1-4A1N1.

However, some reseller pages describe N-code drives as having a brake chopper. They are wrong by Eaton’s key. So trust the key and the nameplate, not a listing blurb.

Worked SVX9000 catalog number examples

  • SVX100A1-4A1N1 and SVX100A2-4A1N1: the same 100 hp, 480 V drive. The first is NEMA 1 and the second is NEMA 12.
  • SVX100A1-4A1B1: the NEMA 1 drive with an internal brake chopper.

Also note that the 2014 enclosed-drive catalog uses a different key. It uses letters such as A (IL, no brake chopper), B (IL, internal brake chopper) and D (IH, no brake chopper). Because of this, check the document edition before you decode. The product series catalog on Precision’s site holds the key.

NEMA 1 vs NEMA 12 Eaton SVX9000 drives

NEMA 1 or NEMA 12: which enclosure do I need for an SVX9000?

Electrically, the two versions are the same SVX9000 Eaton drive. The difference is the enclosure. NEMA 1 (IP21) suits clean, dry indoor rooms and panels. NEMA 12 (IP54) suits dusty areas or places where liquid may drip.

Two white isometric enclosures on a gray platform: the left one has vented slots (NEMA 1), the right one has a gasketed
Conduit runs enter from below, and the door seal is visible around its edge.

In addition, both enclosures run from -10 to +50 C without derating. Also, the drive holds 100% load capacity up to 3300 ft (1000 m). Above that altitude, check the manual for derating.

Match the enclosure digit in the catalog number to the room, not just to the old drive. For example, if the drive sits in a dusty plant, the NEMA 12 version is the safer pick.

How much do altitude, heat and switching frequency reduce current?

Derating means you take less current from the drive so it stays cool. Above 3300 ft (1000 m), the usual rule for this drive family is about 1% less current for each 330 ft (100 m). Confirm that figure in the manual for your frame.

Likewise, ambient air above 50 C and a switching frequency above the default both cut the allowed current. The size of the cut depends on frame and voltage, so read the derating tables in the 9000X user manual. If your site is hot, high or both, size up a frame rather than run the drive at its limit.

SVX9000 features that matter in the field

What control modes does the Eaton SVX 9000 have?

First, the SVX gives you V/Hz control with boost and slip compensation, plus open-loop sensorless vector control. Closed-loop encoder control is only on the SPX9000. Start and speed sources include the keypad, I/O and fieldbus.

Built-in applications include local/remote, multi-step speed, PID, multi-purpose, and pump and fan control with auto-changeover. A reseller lists PFC for one to five pumps. Also, a Quick Start wizard helps with first setup.

Which fieldbus options work with the SVX9000?

Next, the control module accepts up to five option cards. These include analog and digital I/O and fieldbus cards. A reseller lists CANopen, PROFIBUS-DP, DeviceNet and LonWorks. In addition, Eaton’s catalog adds Metasys N2 through the OPTC2 board.

As a reference, the SVX010A2-4A1B1 listing shows 6 digital inputs, 1 analog input, 1 analog output, 1 NPN output and 2 relay outputs. That is what the standard A9/A2 boards provide together. The drive has no integrated communications, so fieldbus needs a card.

Which option boards fit which slots?

On this drive family, slots A and B hold the basic I/O boards, such as the standard A9 and A2. Slots C, D and E take the expansion and fieldbus boards. Not every OPT board fits every slot, so check the board’s instructions and the option board section of the manual before you order.

Does the SVX9000 have a built-in brake chopper?

It depends on size and voltage. A brake chopper is standard on 1-30 hp at 380-500 V and on 3/4-15 hp at 208-230 V. However, all 575 V drives ship without one (option N).

So a 100 hp drive needs the B option or an external chopper if the load needs braking. For setup, check the manual and the Eaton application manual (MN04004001E).

How do I size a braking resistor for a B-option drive?

Start with the load. Work out the peak braking power and how long and how often the drive brakes. Then pick a resistor with these limits in mind:

  • Ohms: the resistor value must not be lower than the minimum in the manual for your drive. A lower value can overload the chopper. As a rule, resistance equals the brake DC voltage squared, divided by peak braking power.
  • Watts: the continuous rating must cover the average braking power, which depends on the duty cycle. Short, rare stops need less than frequent ones.
  • Protection: use a resistor with a thermal switch, and wire that switch into your stop circuit.

Then wire the resistor to the drive’s brake resistor terminals, using the terminal names and cable size in the manual. Keep the leads short, and mount the resistor where its heat is safe. Finally, check that the brake chopper is enabled in the drive’s parameters.

Where the SVX9000 Eaton drive fits and where it does not

What applications is the SVX9000 suited for?

First, Eaton lists pump, fan and conveyor systems as typical uses. In practice, the Eaton SVX adjustable frequency drive also fits compressors and general machinery. These loads rarely need tight closed-loop speed control.

However, it is a poor fit for jobs that need encoder feedback. For those, look at the SPX9000 or a newer drive. Also, the SVX has no AC line regeneration, according to one retailer spec. As a result, an overhauling load, such as a lowering hoist, needs braking resistors or a different drive.

Finally, confirm any special function against Eaton’s product specification guide before you commit.

SVX9000 vs SPX9000 vs Danfoss NXS vs PowerXL DG1

How does the SVX9000 compare with the alternatives?

Here is a quick view of each path:

Four navy-and-white variable frequency drive cabinets stand in a row on a table with cardboard boxes, pliers, and a
Note the orange-fronted unit, which catches the eye among the rest of the lineup.
  • SPX9000: adds closed-loop vector control. Our separate SVX vs SPX post covers the details.
  • Danfoss NXS: a distributor says the SVX series was the Danfoss NXS in a different skin. The same source calls it a drop-in with the same menu and fieldbus files. That claim does not come from Eaton or Danfoss, so verify ratings, option cards and firmware.
  • PowerXL DG1: Eaton’s successor drive. It is not a plug-in swap. Check mounting, wiring, parameters and option cards.

With a DG1, verify horsepower, voltage class and functions such as safe torque off or encoder feedback. Also count electrician hours, panel changes and PLC reprogramming in the cost.

Which replacement path should you choose for an SVX9000?

First, repair the drive if the frame is large and the unit is otherwise sound. Next, swap like-for-like if you can find the exact catalog number. Finally, migrate when control boards or option cards cannot be found. The PowerXL DG1 and SVX enclosed drives installation manual covers both families.

Sullair-coded SVX9000 drives

What is a Sullair SVX9000 drive and how do I order one?

Precision lists four 100 HP Sullair SVX9000 drives at 480 V and 140 A. Part numbers 02250147-547 and 02250165-113 are NEMA 12. Part numbers 02250145-105 and 02250169-537 are NEMA 1.

However, these are OEM-numbered units. We do not claim they match a standard Eaton catalog number. So match the Sullair part number on your old drive, not just the hp and voltage.

For the two NEMA 12 units, specify a Supervisor or WS controller when you order. If you are unsure, contact Precision before you buy.

What to confirm before ordering a replacement SVX9000 Eaton drive

What should I check before ordering an SVX9000?

Use this list with the nameplate of the old drive in hand:

Isometric illustration of an orange industrial enclosure with an open side showing a coiled copper inductor, beside
Check the display panel on the housing top for the old unit’s model readout.
  1. Match the full catalog number, including the enclosure digit and brake letter.
  2. Confirm the voltage class, the amp rating and whether it is IH or IL, and the frame.
  3. Note the option cards, fieldbus and keypad type on the old drive.
  4. Record the firmware or application software, if you can read it.
  5. For OEM units, match the OEM part number and controller type.

Next, ask about the warranty. For instance, the SVX010A2-4A1B1 listing shows a 2 year manufacturer warranty. Because these are legacy parts, check stock or contact Precision for availability. Also, do not trust prices from old catalogs.

Installing and replacing an SVX9000 safely

How should I wire and torque an SVX9000?

The 9000X manual requires copper wire rated at least 75 C. Next, torque power terminals by frame. For 480 V, the manual gives these values:

  • FR8 (75-125 hp): 340/187 in-lbs (40/22 Nm)
  • FR7 (40-60 hp): 85 in-lbs (10 Nm)
  • FR6 (20-30 hp): 35 in-lbs (4 Nm)
  • FR5 (7.5-15 hp): 13 in-lbs (1.5 Nm)

Before first power, check the input cable insulation between phases and to ground. The result must be above 1 megohm. Likewise, check the motor cable the same way.

Use the manual’s tables for fuse, circuit breaker and cable sizes, because they change by frame and voltage. Before you open any drive, follow the manual’s discharge and lockout steps. Finally, for keypad programming and the start-up wizard, our training lessons walk you through it.

Troubleshooting and when to repair or replace an SVX9000

What do SVX9000 fault codes mean?

The fault code appendix in the 9000X manual lists every code with its cause and remedy. A fault stops the drive and shows an F number on the keypad. A warning shows with an A prefix and the drive keeps running, so treat it as an early alert. Here are common faults, as listed for this drive family:

Illustration of a technician in a hard hat and blue coveralls testing an orange variable frequency drive inside an open
Multimeter leads coil on the cabinet floor near the wiring loom.
CodeFaultCommon causes
F1OvercurrentSudden load increase, short circuit in the motor cable, wrong motor size
F2OvervoltageDeceleration time too short, voltage spikes on the supply
F3Earth faultFailed insulation in the motor or its cable
F9UndervoltageLow supply voltage, supply loss, internal fault
F10Input line supervisionMissing input phase
F11Output phase supervisionNo current in one motor phase, such as a loose or broken lead
F12Brake chopper supervisionNo brake resistor, broken resistor, chopper failure
F14Drive overtemperatureBlocked airflow, dirty heatsink, failed fan, hot room
F16Motor overtemperatureOverloaded motor or too little cooling

First, read the code, then follow the manual’s cause and remedy steps. Because numbering can vary by software version, confirm each code in the appendix for your drive before you act.

When should I repair or replace an SVX9000 Eaton drive?

Repair makes sense when the frame is large and the drive is otherwise sound. However, replace or migrate when control boards or option cards are unobtainable. In addition, call for help if the drive trips repeatedly on overcurrent or has a failed power section. Our Eaton SVX9000 repair post explains the process.

Manuals, firmware and documents for the Eaton 9000X SVX drive

Where do I get the SVX9000 manual, firmware and quick start guide?

Go to Eaton’s SVX9000 product page. It lists the application manual (MN04004001E), the product specification guide, the SVX/SPX add-on instructions and the release notes. It also lists firmware SVX00031V032, dated 28/06/2024.

Here is which document answers which question:

  • 9000X VFD user manual (MN04001004E): wiring, torque, startup, derating, dimensions and faults.
  • SVX9000 application manual (MN04004001E): built-in applications and parameters.
  • Product series catalog and the 2006 catalog (CA04000006E): ratings and catalog number keys.
  • PowerXL DG1 and SVX enclosed drives installation manual: enclosed drives and DG1 migration.

Frequently asked questions

What is the Eaton SVX9000?

It is a general-purpose AC variable frequency drive in Eaton’s 9000X family, formerly Cutler-Hammer. It uses V/Hz and open-loop sensorless vector control. For example, typical uses are pumps, fans and conveyors.

Is the Eaton SVX9000 still available?

Eaton marks many SVX catalog numbers as discontinued or to be discontinued, so it depends on the exact number. Distributors point to the Danfoss NXS or Eaton’s PowerXL DG1 as replacement paths. However, verify ratings and options for either.

What is the difference between SVX9000 and SPX9000?

The SVX9000 offers V/Hz and open-loop sensorless vector control. Closed-loop encoder-feedback control is only on the SPX9000. Even so, the same 9000X user manual covers both.

How do I read an SVX9000 catalog number like SVX100A1-4A1N1?

SVX is the family and 100 is the hp code. A is standard software, 1 is NEMA 1 (2 is NEMA 12), and 4 is the 380-500 V class. Then the next A is the alphanumeric keypad, 1 means standard boards, and N is no brake chopper (B is an internal one). Finally, the last 1 is standard coating, and 2 means conformal coating.

Why does a 100 HP SVX9000 show 261 A at 240 V but 140 A at 480 V?

Current rises as voltage falls for the same power. Also, both figures are on the same IH basis (100 hp IH), so voltage explains most of the gap. At 480 V, the same drive is 125 hp IL at 170 A.

Where can I download the SVX9000 Eaton manual?

Eaton’s 9000X VFD user manual (MN04001004E) covers both the SVX9000 and SPX9000. In addition, Eaton’s SVX9000 product page lists the application manual, firmware and release notes.

The SVX9000 Eaton drive is a solid legacy workhorse, but you need the exact catalog number, voltage class and duty rating to order the right one. When a number is discontinued, check Eaton’s status page and plan your repair or replacement path. If you need a quote, a repair or help matching a drive, contact Precision Electric or browse our SVX9000 drives.