Free Shipping on Motors Over $350!
Precision Electric, Inc.
A Family Owned
Small Business
USA Icon
Welcome, register
or login

Login

Forgot Password?
New to Precision Electric?

Register

A link to set a new password will be sent to your email address.

Have an account with Precision Electric?
Tracking
& Orders
Shop Or Ask Questions By Phone
574-256-1000
  • 0 Cart Icon
    Shopping Cart
  • Login/Register
  • Drives
    • AC Variable Frequency Drives
    • DC Variable Speed Drives
    • Need A Drive Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Softstarters
    • AC Motor Softstarters
    • Need A Softstarter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Phase Converters
    • Rotary Phase Converters
    • VFD Phase Converters For Motors
    • Need A Phase Converter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Motors
    • AC Motors
    • Need A Motor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Reactors
    • Input Line Reactors
    • Output Load Reactors
    • Need A Reactor Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Filters
    • Input EMC Filters
    • Input Harmonic Line Filters
    • Output dv/dt Filters
    • Output Sinewave Filters
    • Need A Filter Repaired? Click Here To Get A Packing Slip For A Free Quote
  • Free Repair Quotes
    • Ready To Send An Item? Click Here To Get A Packing Slip For A Free Quote
    • AC Drive Repair
    • AC Motor Repair
    • DC Drive Repair
    • DC Motor Repair
    • Servo Drive Repair
    • Pump Repair
    • PCB Repair
    • Servo Motor Repair
    • Other Electronics Repair
  • On-Site Service
    • AC / DC Drives
    • AC / DC Servo Drives
    • AC / DC Servo Motors
    • AC / DC Motors
    • Computers & PCs
    • Pumps
    • Electronics & PCBs
    • Automation Systems
    • System Retrofits
    • Systems Integration
    • Preventive Maintenance
    • Vibration Analysis
    • Infrared Thermography
    • Energy Savings
  • Support
    • Call 574-256-1000
    • Contact Us
    • About
    • Product Manuals
    • Technical Blog
    • Baldor / ABB IEC And NEMA Motor Frame / Motor Size Reference Charts
    • Submit A Support Ticket
    • Request Product Return Authorization
    • Request Product Warranty Authorization
    • Request An Open Account
  • VFD Training Videos
  • Menu Menu
Wire Transfer Logo EASA Logo Free Shipping on Orders Over $350 Logo EASA Accreditation Logo AEGIS Partner Logo EASA Accreditation Logo SSL Secure Logo
ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 30.0 HP @ 240V | Max Current: 80.0 Amps | Control Voltage: 100 - 250 VAC - PSE85-600-70-240V
NEW, FACTORY SEALED!

Prices Include:

  • FREE Ground Shipping On Drives And Softstarters

    Storewide On All Drives And Softstarters Over $350*

  • Unlimited US Based Phone Support

    Contact Us Any Time At 1-574-256-1000.

  • Access To Our Team Of Engineers

    Trust Our Over 100 Years Combined Industry Experience

  • American Small Business

    Family Owned And Operated Customer Service Since 1983.

  • Hassle Free Warranty Claims

    We Help Process Warranty Replacement & Repair Claims.

ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 30.0 HP @ 240V | Max Current: 80.0 Amps | Control Voltage: 100 – 250 VAC – PSE85-600-70-240V

$ 1619 07

In Stock

Quantity: 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
View Cart

Send Enquiry for ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 30.0 HP @ 240V | Max Current: 80.0 Amps | Control Voltage: 100 – 250 VAC – PSE85-600-70-240V

Unauthorized enquiry
Enquiry email sent successfully!

Need Member, Reseller, or OEM Pricing?

Register or Login

Estimated Repair Price: $485.72 - $1,133.35

Request a Repair Quote
  • Specifications
  • Overview
  • Manuals

Product Specifications

ManufacturerABB (FE)
SeriesPSE Series
Model #PSE85-600-70-240V
Warranty:1 Year Manufacturer
Horsepower30.0 HP
Input Voltage(s):200 - 240 VAC Input,
Output Voltage(s):240 VAC Output
Rated Current:80.0 Amps
Input Phase:Three Phase Input
Output Phase:Three Phase Output
Enclosure:Not Rated
Height10 in
Width4 in
Depth7 in
Weight6 lbs
Learn MoreYou can hover your mouse over highlighted product specs to learn more.

Description

The PSE series softstarters are one of the latest innovations from ABB. It is built to ensure an optimal balance between high starting capacity and cost efficiency. The new PSE softstarters are designed by taking into considerations the modern needs of worldwide industries. One of the key problems that the PSE series softstarters intend to solve is water hammering. Known as a phenomenon where the water collides with the pump and valve at great force when the pump is stopped, water hammering is known to decrease the lifespan of the pump and related mechanism. The PSE series softstarters is built with a torque control mechanism. This advanced feature prevents the motor from stopping right away and resulting in excessive stress on the pump. The PSE softstarters also featured protective coatings on the circuit board, which ensure the unit last in harsh environment PSE series softstarter While the PSE series softstarters is built for simplicity and efficiency, that doesn’t mean that system installers will have to struggle with the setups. The softstarter has a built-in LCD and keypad which provides a convenient interface for both configuration and monitoring. During operations, the technicians can obtain the status of the softstarter instantly from the four LEDs on the panel. Energy efficiency is crucial in industrial application, and the PSE series softstarters are engineered with that in mind. The softstarters feature built-in by-pass that minimize energy usage when the full voltage is achieved.   Highlights of the PSE Series softstarters:
  • Wide rated operational voltage 208–600 V AC
  • Wide rated control supply voltage 100–250 V, 50/60 Hz
  • Rated operational current 18 to 370 A
  • Wide ambient temperature range, -25 to +60 degrees Celsius
  • Coated circuit boards for reliable operation in harsh environments
  • Built-in by-pass on all sizes, saving energy and reducing installation time
  • User friendly HMI with illuminated language neutral display and four button keypad
  • Torque control for excellent control of pumps
  • Current limit, adjustable between 1,5-7xIe
  • Motor overload protection with classes 10A, 10, 20 and 30
  • Motor underload protection and locked rotor protection
  • Kick start to start jammed pumps or conveyor belts
  • Analog output showing operational current, 4-20 mA
  • Prepared for fieldbus communication using Profibus, Modbus, Devicenet or CANopen

PSE85-600-70-240V PSE Series Features

1. PSE85-600-70-240V PSE Series Motor Protection

The PSE series is built with both overload and underload protection. Overheating on the PSE softstarters will be a non-issue as it has the ability to detect stalled motor. The softstarter can also intelligently detect broken belts and dry pumps to activate the necessary response for underload protection.

2. PSE85-600-70-240V PSE Series Analog Output

While the PSE series softstarters are equipped with modern LCD HMI, analog outputs are not neglected either. With a standard 4-20 mA analog output, an analog meter can be installed to monitor the current usage in real time without installing a current transformer.

3. PSE85-600-70-240V Fieldbus Communication

An optional Fieldbus communication module can be integrated into the PSE series softstarters. This allows the softstarter to be connected to remote servers or PLC with standard industrial protocols. By doing so, technicians can configure, support and monitor the softstarter remotely, making maintenance more efficient.

PSE85-600-70-240V PSE Series Other Features

1. PSE85-600-70-240V Specifications

  • Degree of protection (Operational circuit) : IP 00
  • Operating position : Vertical at ± 30°
  • Ambient temperature
    • Storage: -40° C to + 70° C (-40 o F to 158 o F)
    • Operation: -25°C to + 40° C (-13 o F to 104 o F) without derating. + 40° C to + 60° C (104 o F to 140 o F) with derating 0.6 % /1 o C (0.6% / 1,8 o F).
  • Altitude
    • 1000 m (3281 ft.) above sea level without derating.
    • 1000-4000 m (3281 - 13123 ft.) above sea level with derating 0.007% / m
  • Pollution degree :3
  • Relative humidity : 5-95% (non-condensing)
  • Standards : IEC 60947-1 | IEC 60947-4-2 | EN 60947-1 | EN 60947-4-2 : UL 508
 

2. PSE85-600-70-240V Technical Data

  • Rated insulation voltage, Ui : 600 V
  • Rated operational voltage, Ue : 208-600 V 50 / 60 Hz
  • Rated control supply voltage, Us : 100 - 250 V 50 / 60 Hz
  • Voltage tolerance : +10% to -15%
  • Frequency tolerance : ± 5%
  • Rated impulse withstand voltage : 6 kV operational circuit / 4 kV control supply circuit
  • Number of controlled phases : 2
  • Inputs : Reset
  • Analog out : 4-20 mA
  • Cooling system : Fan
  • Rated form : Form 1
  • Rated duty : Uninterrupted
  • EMC : IEC 60947-4-2 Class A Lloyds Register (2002)
  • Recommended fuse Supply circuit : 6A Delayed MCB use characteristics
  • Communication protocols : DeviceNet/Profibus/Modbus/CANopen

3. PSE85-600-70-240V Weights

  • ..60 : 2.4 kg / 5.3 lbs
  • ..105 : 2.5 kg / 5.5 lbs
  • ..170 : 4.2 kg / 9.2 lbs
  • PSE210 : 4 kg / 27.3 lbs
  • ..370 : 13.9 kg / 30.6 lbs
 

4. PSE85-600-70-240V LED Status Indicators

  • Ready ( Green)
    • Off: when control supply voltage Us is off or unconnected.
    • Flashing light when control supply voltage Us is On and operational voltage Ue is Off.
    • Steady light when control supply voltage Us is On, and operational voltage Ue is On
  • Run (Green)
    • Off when the motor not is running.
    • Flashing light when softstarter is controlling operational voltage Ue during start or stop ramp.
    • Steady light when full operational voltage Ue is on at Top of Ramp.
  • Protection (Yellow)
    • Off: when the softstarter has not tripped on any protection
    • Steady light on protection when reset is not possible.
    • Flashing light on protection when reset is possible
  • Fault (Red)
    • Off: when the softstarter has not tripped on any fault
    • Steady light on fault when reset is not possible.
    • Flashing light on fault when reset is possible.

PSE Series Technical Manuals

Product Manuals

  • PSE18-370 PS-FBPA Manual (4.13 MB)
  • PSE18-370 Softstarters User Manual Short Form (54.32 MB)
  • PSE18-370 Softstarters Installation and Commissioning Manual (19.72 MB)
  • PSE18-370 Address Map for CANopen 01.01.00 and 01.01.02 (117 KB)

Options Manuals

  • PSE18-370 Installation Instruction for External Keypad PSEEK (3.47 MB)
  • PSE18-370 Fieldbus Communication Internal Modbus RTU (1.17 MB)
  • PSE18-370 Fieldbus Communication for Profibus DP V0-V1 (579 KB)
  • PSE18-370 Fieldbus Communication for Modbus RTU (645 KB)
  • PSE18-370 Fieldbus Communication for DeviceNet (554 KB)
  • PSE18-370 Fieldbus Communication Fieldbus Plug Modbus TCP (824 KB)
  • PSE18-370 Changing of Thyristors and Bypass Relay-Contactor (885 KB)
  • PSE18-370 Changing of HMI Module (730 KB)
  • PSE18-370 Changing of Fans (1.50 MB)

Catalogs & Brochures

  • PSE18-370 Softstarter Main Catalog (16.64 MB)
  • PSE18-370 Softstarter Panorama (1.04 MB)
  • PSE18-370 Spare Parts Catalog for Softstarter (3.13 MB)

Declaration Of Conformity

  • PSE18-370 CE Declaration of Conformity - Softstarter (56 KB)

Facility Location:

1508 W 6th St Mishawaka, IN 46544

Free Ground Shipping on Motors, Drives And Softstarters Over $350

*Cart total must exceed $350 before taxes. Some product exclusions may apply, discount is applied automatically in the cart during checkout. For remote ‘limited access’ or Residential addresses that require special lift gate services, additional fees may apply. Please specify special shipping circumstances to avoid or limit these charges.

Certifications:

Payment Option Certifications

BBB Rating Certification



Snell Group Certification

Vibration Institute Certification

Categories

  • ABB ACS355
  • ABB Drives
  • AC Motor Speed Controllers
  • AC Tech SMVector
  • Accessories & Options
  • Articles
  • Automation & Control Systems
  • EATON SVX9000
  • Electric Motors
  • FAQ Automation
  • FAQ Electronics
  • FAQ Mechanical
  • FAQ Motor Shop
  • FAQ VFDs
  • FAQs
  • Field Experiences
  • How-To
  • HT SMVector VFD
  • HT VFDs
  • Industrial
  • Machine Shop Videos
  • News
  • Phase Converters
  • Power-Quality Components
  • Product Manuals
  • Repair & Field Services
  • Sensors & Feedback Devices
  • Service Offerings
  • Servo Drives & Motion Control
  • Servo Motors
  • Servo Motors
  • SMVector Drives
  • SMVector Series
  • Soft Starters & Motor Starters
  • Training Videos
  • Tutorials
  • Uncategorized
  • Variable Frequency Drives (VFDs)
  • Video Series

From The Blog:

  • Allen Bradley PowerFlex 525: Setup, Specs & Alternatives
  • Allen Bradley Power Flex 525 — Specs, Setup, And Best Uses
  • Allen Bradley Frequency Drive: Technical Guide & Alternatives
  • AC Motor Speed Controller: Complete Engineering Guide
  • VFD Motor: How To Specify, Install And Optimize
© Copyright - Precision Electric, Inc.
  • Link to X
  • Link to Facebook
  • Link to Youtube
  • Link to LinkedIn
Link to: ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 15.0 HP @ 240V | Max Current: 42.0 Amps | Control Voltage: 100 – 250 VAC – PSE45-600-70-240V Link to: ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 15.0 HP @ 240V | Max Current: 42.0 Amps | Control Voltage: 100 – 250 VAC – PSE45-600-70-240V ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 15.0 HP...
NEW, FACTORY SEALED!
Link to: ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 40.0 HP @ 240V | Max Current: 104.0 Amps | Control Voltage: 100 – 250 VAC – PSE105-600-70-240V Link to: ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 40.0 HP @ 240V | Max Current: 104.0 Amps | Control Voltage: 100 – 250 VAC – PSE105-600-70-240V
NEW, FACTORY SEALED!
ABB IP00 PSE Series Solid-State Reduced Voltage 3 Phase Softstarter | 40.0 HP...
Scroll to top Scroll to top Scroll to top