ABB AF65 30 00 11 Contactor: Decode the Code, Ratings and Coil
If you hold a part number like the ABB AF65 30 00 11, you need to know what it is, what the digits mean and what else to order with it. This guide decodes the code, compares it with the AF65-30-11-13, and explains the ratings, overload relays and accessories. As a result, you can order the right contactor with confidence by the end.
On this page
- What the ABB AF65-30-00-11 is
- How to read the AF65 part number
- AF65-30-00-11 vs AF65-30-11-13: what changes
- AF65 ratings explained: AC-3, AC-1 and UL hp
- The AF65 coil: wide voltage range, surge protection and holding power
- Accessories and overload relays that fit the AF65
- Where the AF65 fits in the AF range and what the alternatives are
- Wiring, mounting and commissioning notes with the ABB AF65-30-00-11
- Troubleshooting and when to repair or replace an AF65
- How to order the right AF65 and what to check first
- Frequently asked questions
What the ABB AF65-30-00-11 is
What is the ABB AF65-30-00-11?
The ABB AF65 30 00 11 is a 3-pole block-type contactor from ABB’s AF range. In simple terms, a contactor is a heavy-duty switch that a small control signal opens and closes to start and stop a load. Also, this one has screw terminals, built-in surge protection and an electronically controlled coil.
For reference, ABB lists it as a 690 V IEC / 600 V UL contactor. Its order code is 1SBL387001R1100. In addition, the catalog description reads “AF65-30-00-11 24-60V 50/60HZ 20-60VDC Contactor.”
What are the ratings of the AF65-30-00-11?
First, each rating belongs to a type of duty. Here are the figures from ABB’s product page:
- Motor duty (IEC): up to 30 kW at 400 V AC-3.
- Motor duty (UL): up to 50 hp at 480 V.
- Power circuits, non-inductive load: up to 105 A AC-1.
- UL general use: 90 A.
In general, AF65 contactors switch power circuits up to 690 V AC and 220 V DC. Most often, people use them for 3-phase motors and for loads that are non-inductive or only slightly inductive.
AF65-30-00-11 quick spec table
| Item | AF65-30-00-11 |
|---|---|
| ABB order code | 1SBL387001R1100 |
| Main poles | 3 |
| Voltage rating | 690 V IEC / 600 V UL |
| Coil range | 24-60 V 50/60 Hz AC, 20-60 V DC |
| Built-in auxiliary contacts | None, per the 00 in the code |
| Terminals | Screw |
| Width | 55 mm |
| Height | 125.5 mm |
| Depth | 111 mm |
| Weight | 0.97 kg |
| Instruction manual | 1SBC101036M6801 |
How to read the AF65 part number
What does AF65-30-00-11 mean?
First, each block of the code has a job. AF65 is the frame size. Then, the 30 means three main poles and no extra main pole.

The next two digits, 00, show the built-in auxiliary contacts. For this part, that means none. However, this reading comes from ABB’s catalog naming and a distributor’s breakdown, so confirm it on the ABB page. By contrast, a code with 11 in that slot, such as the -30-11-13, means one normally open and one normally closed auxiliary contact (1NO+1NC) are fitted.
Finally, the last two digits are the coil code. In the AF65-30-00-11, 11 means a 24-60 V AC / 20-60 V DC coil.
What do the last two digits of the AF65 coil code mean?
First, the coil code tells you what control voltage the contactor needs. Next, ABB’s AF catalog lists these codes:
| Coil code | Control voltage |
|---|---|
| 41 | 24-60 V AC only |
| 11 | 24-60 V AC / 20-60 V DC |
| 12 | 48-130 V |
| 13 | 100-250 V |
| 14 | 250-500 V |
In practice, the coil code is the most common cause of wrong orders. For example, two parts can look the same and carry the same power ratings, yet one will not run on your control supply. So always check the last two digits first.
AF65-30-00-11 vs AF65-30-11-13: what changes
What is the ABB AF65-30-11-13?
The ABB AF65 30 11 13 is the same size of contactor with a different coil and extra contacts. In addition, ABB describes it as a 3-pole contactor with pre-mounted auxiliary contacts and screw terminals. Also, its control range is 100-250 V, 50/60 Hz and DC, and its order code is 1SBL387001R1311.
ABB’s page also says the block-type design can take add-on auxiliary contact blocks and accessories. Likewise, its power ratings match the AF65-30-00-11: 30 kW AC-3 at 400 V, 50 hp at 480 V UL, 105 A AC-1 and 90 A UL.
What is the difference between AF65-30-00-11 and AF65-30-11-13?
In short, only the coil and the auxiliary contacts differ. The power poles are the same.
| Feature | AF65-30-00-11 | AF65-30-11-13 |
|---|---|---|
| Order code | 1SBL387001R1100 | 1SBL387001R1311 |
| Coil | 24-60 V AC / 20-60 V DC | 100-250 V AC/DC |
| Built-in auxiliary contacts | None | 1NO+1NC pre-mounted |
| Main ratings | 30 kW / 50 hp / 105 A AC-1 / 90 A UL | Same |
Every AF65 coil code also comes in a 1NO+1NC version. For example, the -11-11 is 1SBL387001R1111, the -11-12 is 1SBL387001R1211 and the -11-14 is 1SBL387001R1411. In all cases, these share the same 30 kW, 105 A, 50 hp and 90 A ratings.
Which AF65 do I need for 24 V, 120 V, 208/240 V or 480 V control?
First, match the coil to the voltage your control circuit puts out. Use this guide:
- 24 V AC or DC: the 11 coil, as on the ABB AF65 30 00 11.
- 120 V AC, 208/240 V AC, or 110/125/220 V DC: the 13 coil, as on the AF65-30-11-13.
- 480 V control: the 14 coil (250-500 V), such as the AF65-30-11-14.
However, the two parts are not interchangeable unless you confirm the control supply first. For example, a 120 V signal on a 24-60 V coil is outside the allowed band.
AF65 ratings explained: AC-3, AC-1 and UL hp
Why do resellers list 65 A, 68 A, 90 A and 105 A for the same AF65?
Resellers copy figures from different places, and they often drop the duty label. As a result, the same AF65 shows up with 65 A, 68 A, 90 A or 105 A. In addition, some listings even call the frame an AF40 or AF30. So check each figure against ABB’s page.

In fact, the ABB figures belong to different duties:
- 30 kW at 400 V AC-3: motor duty under IEC rules. The rated AC-3 current at 400 V is 65 A, so the 65 A on reseller listings is the motor current.
- 105 A AC-1: non-inductive or slightly inductive loads, such as heaters.
- 90 A and 50 hp at 480 V: the UL rating.
So match your load to the right line. For example, a motor uses the kW, AC-3 current or hp rating. A heater uses the AC-1 rating. For the AC-3 current at 690 V, read the ABB datasheet.
What temperature limits apply to the AF65?
First, the ABB listing gives an ambient range of -25 to +60 °C with a thermal overload relay fitted. However, without a relay, the range is -40 to +70 °C. In either case, keep your panel inside those limits.
The AF65 coil: wide voltage range, surge protection and holding power
Is the AF65 coil AC or DC, and how does the electronic coil work?
In short, the coil accepts both. First, an electronic interface rectifies the AC or DC control voltage and feeds a DC voltage to the coil. Because of this, only four coils cover 24-500 V AC and 20-500 V DC across the range. Also, the 100-250 V coil is the core coil, and ABB says it covers all standard network voltages.
However, the wide range has limits. The coil accepts the full range printed on the part, such as 24-60 V on the ABB AF65 30 00 11. Any voltage outside that band is not allowed. So one coil can serve different control voltages, but only inside its own band.
Does the AF65 need an external surge suppressor?
No. The AF65-30-00-11 has surge protection built in, so you do not add a separate suppressor across the coil. The electronic design also uses little power to hold the contactor closed. In fact, ABB says it cuts coil energy use by 80%.
For the AF65-30-11-13, a distributor lists average holding power of 4 VA AC and 2 W DC. However, we did not find a holding figure for the 11 coil, so check the ABB datasheet. Also, ABB says AF..-30-..-11 contactors are not suitable for direct control by a PLC output. Direct PLC control above 250 mA needs the dedicated 24 V DC (AF..Z) coil, which ABB lists only up to AF38Z. The 24-60 V coil on the AF65-30-00-11 is not that coil.
How do I control an AF65 from a 24 V DC PLC output?
Use an interface relay between the PLC and the contactor. First, wire the PLC output to the coil of a small relay rated for that output. Then use the relay’s contact to switch a control supply to A1 and A2 of the AF65.
Make sure that supply sits inside the 24-60 V AC / 20-60 V DC band of the 11 coil. In this way, the PLC only carries the small relay coil current. Also, the relay contact carries the contactor coil current.
Accessories and overload relays that fit the AF65
Which overload relay fits the AF65 (TF65 or EF65)?
ABB lists two relays for the AF65. First, the TF65 is a thermal relay with a 22-67 A range and trip class 10. Second, the EF65 is an electronic relay. However, a 2016 ABB catalog gives its range as 25-70 A, and a later catalog says 20-70 A, so check the current datasheet.

Also, both mount directly on the contactor. For example, TF65 order codes run from TF65-28 (1SAZ811201R1001) to TF65-67 (1SAZ811201R1007). Meanwhile, the DB65 kit (1SAZ801901R1001) is for mounting the TF65 on its own. In addition, terminal screws on both relays take about 4 Nm.
Choose the range from the motor nameplate current. Then set the relay to the motor’s full-load amps, not to the contactor rating.
Worked example: sizing for a 400 V, 55 A motor
First, check the contactor. The AF65 is rated 65 A AC-3 at 400 V, so a 55 A motor fits with some margin.
Next, check the overload relay. A 55 A motor falls inside the 22-67 A TF65 range. Pick the TF65 size whose adjustment band covers 55 A, then set the dial to the nameplate current. However, we do not list the exact band for each size here, so match your 55 A against the TF65 datasheet to choose the catalog number. The same check works for the EF65.
Finally, wire the coil to a supply that matches the coil code, such as the 11 coil for 24 V control.
How do I add auxiliary contacts to an AF65?
First, look at the part you have. The AF65-30-00-11 has none built in, so add a block. For example, ABB shows the CAL4-11 2-pole auxiliary block with the AF65, and the block-type design takes add-on contact blocks. Also, fitting an overload relay does not stop you from adding many other accessories.
If you need the contacts from day one, order a version with 1NO+1NC pre-fitted. For 24-60 V control, that is the AF65-30-11-11.
Where the AF65 fits in the AF range and what the alternatives are
How does the AF65 compare with AF52 and AF80?
For comparison, ABB’s US IEC controls catalog lists the neighbors by current and horsepower:
| Frame | Current | Horsepower |
|---|---|---|
| AF52 | 80 A | 40 hp |
| AF65 | 90 A | 50 hp |
| AF80 | 105 A | 60 hp |
Then pick the frame that covers your motor with some margin. Also, the 13 and 14 coil codes are listed for the AF65 and AF52. If you need a safety-rated contactor, ABB also makes AFS safety contactors (AFS40 to AFS65). In addition, they take the same TF65 and EF65 relays.
When should I use a drive or soft starter instead of an AF65 contactor?
A contactor switches a motor fully on or fully off. Generally, that works well for fixed-speed loads such as pumps and conveyors that run at one speed. However, if you need speed control, a drive is the better tool. Meanwhile, a soft starter suits a motor that runs at full speed but needs a gentler start.
In some jobs, small drives can replace a contactor. For example, we sell ABB ACS180 and ACS255 drives in 0.5 hp sizes. Still, these are drives, not AF65 contactors. For a 30 kW, 50 hp class motor, check the drive and motor ratings before you decide.
Wiring, mounting and commissioning notes with the ABB AF65-30-00-11
Where do I find the AF65 manual and datasheet?
First, go to ABB’s product page for the part, then open the detailed information and downloads page. Next, the instruction manual number for the ABB AF65 30 00 11 is 1SBC101036M6801. ABB also posts its AF contactors family page, a US catalog for motor protection and control, an IEC controls section and a contactors and overload relays guide. Finally, check the datasheet for conductor sizes and terminal torque on the main and control terminals, since this guide does not list them.

How big is the AF65, and how do I mount it?
The AF65-30-00-11 is 55 mm wide, 125.5 mm high and 111 mm deep. Use these figures to plan panel space, and leave room for an overload relay below the contactor. The AF65 mounts on a DIN rail or with screws.
What should I check when installing the AF65?
First, follow the ABB instructions for terminal torque and conductor sizes. Then work through these steps:
- Confirm the control voltage at A1 and A2 is inside the coil range.
- Tighten the screw terminals to the torque in the manual.
- Set the overload relay to the motor nameplate current.
- Check any auxiliary contacts for the right state.
- Finally, energize the coil and confirm the contactor pulls in cleanly.
Troubleshooting and when to repair or replace an AF65
Why won’t my AF65 contactor pull in?
Start with the control voltage. First, measure at A1 and A2 while you call for a start. Then compare the reading to the coil code. For example, a 120 V signal on a 24-60 V coil is a common mistake.
Next, check the control wiring, stop buttons, interlocks and the overload relay contact. If the contactor chatters or drops out, look for voltage sag and loose wiring. The electronic coil handles some dips. However, a weak supply can still cause trouble.
When should I replace an AF65 rather than repair it?
Replace the contactor if the main contacts are welded or pitted. The AF65 is a block-type unit, so treat the coil as part of the contactor and do not plan on swapping it. Meanwhile, if the contactor works but the motor or drive misbehaves, test those separately and send the failed unit for repair.
How to order the right AF65 and what to check first
What should I check before ordering an AF65?
Finally, use this checklist before you buy:

- Frame: AF65.
- Poles: three.
- Built-in auxiliary contacts: none (00) or 1NO+1NC (11).
- Coil code against your actual control voltage.
- Overload relay range against the motor nameplate current.
- ABB order code: 1SBL387001R1100 or 1SBL387001R1311.
Also, cross-check the ABB order code instead of trusting a reseller description. Price and lead time vary by supplier, so confirm both when you order.
Frequently asked questions
What is the ABB AF65-30-00-11?
It is a 3-pole AF-series block contactor. Its rating is 30 kW at 400 V AC-3 and 50 hp at 480 V UL. In addition, it switches 105 A AC-1 or 90 A UL general use. Finally, the coil is 24-60 V AC (50/60 Hz) or 20-60 V DC, and the order code is 1SBL387001R1100.
What does AF65-30-00-11 mean?
First, AF65 is the frame size, and 30 is three main poles. Next, the 00 means no built-in auxiliary contacts. Finally, the 11 is the coil code for 24-60 V AC / 20-60 V DC.
What is the difference between AF65-30-00-11 and AF65-30-11-13?
In short, the main contacts and ratings are the same. However, the -11-13 has a 100-250 V AC/DC coil and 1NO+1NC auxiliary contacts fitted. Meanwhile, the -00-11 has a 24-60 V AC / 20-60 V DC coil and no built-in auxiliary contacts. So order by your control voltage.
Which overload relay goes with the AF65?
ABB lists the TF65 thermal relay (22-67 A) and the EF65 electronic relay. Also, both mount directly on the contactor. Then choose the range from the motor nameplate current.
Can one AF65 coil work on different control voltages?
Yes, within its band. The electronic coil accepts the full range printed on the part, such as 100-250 V AC/DC on the 13 coil. However, a voltage outside the band, for example 120 V on a 24-60 V coil, is not allowed.
The ABB AF65 30 00 11 and the AF65 30 11 13 share the same power ratings, so your choice comes down to coil voltage and auxiliary contacts. First, check the coil code, match the overload relay to the motor, and confirm the ABB order code before you buy. If you need help with control gear, drives or repair, contact Precision Electric or browse our ABB drives.