ABB NEMA 4X VFDs: Families, Ratings and How to Choose

Illustrated ABB NEMA 4X drive in an open, water-beaded enclosure with an orange label, beside a coiled cable.

If you search for abb nema, you most likely need an ABB drive that mounts on a wet, dusty or outdoor machine without a separate box. This guide covers the ABB NEMA 4X VFD families, what the ratings and type codes mean, and how to pick the right one. Also, you will see which questions to answer before you order.

On this page

What “ABB NEMA” means for drives

What does “ABB NEMA” mean when buying a drive?

On a drive, abb nema refers to the enclosure type from NEMA 250, the standard for enclosure types. In short, it describes the protection around the drive. However, it does not describe a motor frame, although “ABB NEMA” can also point to NEMA-frame motors. For now, this article stays on drives.

For example, ABB marks these drives as “UL Type 4X,” “IP66/NEMA 4X” or “Type 4X/IP66.” Because they belong to the same family of rating, spec sheets and searches use all three.

What is an ABB NEMA 4X VFD and why use one?

An ABB NEMA 4X VFD is a variable frequency drive (a drive that controls motor speed) built in a sealed, corrosion-resistant enclosure. As a result, you can mount it on the machine, in a washdown zone or outdoors. You do not need to build a separate enclosure around it.

As a result, that saves panel-building cost and floor space. In addition, it puts the drive close to the motor.

NEMA 4X vs IP66: are they the same?

Is NEMA 4X the same as IP66?

No. A NEMA 4X enclosure meets IP66, but an IP66 enclosure is not automatically 4X. This is because IP does not test corrosion, external icing, oil or gasket aging. However, NEMA 250 covers all of those. ABB’s drives carry both markings, so you get both.

Two gray isometric enclosures on a plate: one sealed shut, the other open with an orange gasket, beside a blue water
The colored strip around the door is the seal that keeps moisture out.

Also, the crosswalk between the two only runs one way, from NEMA type to IP. Therefore, you cannot convert an IP rating into a NEMA type. NEC 110.28 is cited as saying IP ratings are not a substitute for enclosure type ratings.

What is the difference between NEMA 4 and NEMA 4X?

NEMA 4X is NEMA 4 plus corrosion resistance. Type 4X covers hose-directed water, windblown dust and ice, and it suits indoor or outdoor use. For that reason, it fits washdown, food and beverage, coastal and chemical areas.

If a spec says NEMA 4X, an IP rating alone is not a like-for-like swap. Instead, check that the drive carries the UL/NEMA Type 4X marking.

What voids the rating?

Every opening, fan or fitting you add must carry the same type rating or higher. Otherwise, the enclosure loses its rating. The same goes for fans and air conditioners. Do not drill a hole in an ABB NEMA 4X drive unless the fitting is Type 4X rated.

ABB NEMA 4X VFD families at a glance

Which ABB VFDs are NEMA 4X rated?

Four ABB lines come in a Type 4X/IP66 enclosure: ACS255, ACS580-01 4X, ACH580 4X and ACQ580 for water and wastewater. The table compares them.

FamilyMarkingPower rangeVoltagesBest fit
ACS255 MicroIP66/UL Type 4X0.5 HP and up; +B068 outdoor code up to 30 HP at 480 V115, 230, 480 and 600 V classesSmall machine-mounted loads
ACS580-01 4XUL Type 4X/IP661 to 30 HP (0.75 to 22 kW)1-phase 240 V; 3-phase 208-240 V, 380-500 V, 500-600 VWet process, food and beverage, outdoor pumps and fans
ACH580 4XUL Type 4X1 to 30 HP1-phase 240 V; 3-phase 208-240 V, 380-480 V, 500-600 VOutdoor HVACR
ACQ580 4XUL Type 4X/IP66See ABB’s ACQ580 documentsSee ABB’s ACQ580 documentsWater and wastewater

Standard IP20 or UL Type 1 drives are not NEMA 4X. For example, the ACS180 is a standard drive in our list. As a result, it needs its own enclosure in a wet area.

ABB ACS255 Micro drives (IP66/NEMA 4X)

What is the ABB ACS255 Micro drive and how does it differ from the ACS250?

The ACS255 is an enhanced version of the ACS250, and it replaces it. New features include sensorless vector control for AC induction and PM motors, better short-circuit protection and operating mode selection. Finally, ABB added new ratings.

In fact, the ABB ACS255 is a good example of an ABB washdown VFD. It has a sealed ABS enclosure and a corrosion-resistant heat sink. In addition, it has built-in macros, a keypad on the drive, and only the essential parameters to set.

  • Control: scalar V/Hz (variable and constant torque) and sensorless vector.
  • Communication: RS-485 with Modbus RTU as standard.
  • Uses: conveyors, mixers, pumps, fans and packaging machinery in dusty, wet or chemical-cleaned areas.

What are the ACS255 IP66 operating temperature limits?

One distributor listing shows an ambient range of -10 to 40 °C for the IP66 drive. However, we do not give a derating figure here, because we cannot confirm one. Also, do not carry over the ACS580 numbers to the ACS255.

Before you install, check the ambient temperature table in the ACS255 user manual for your exact type code. If the site runs hotter than 40 °C or colder than -10 °C, ask us or ABB before you order.

ABB ACS580-01 UL Type 4X/IP66

What hp and voltage range does the ACS580 4X cover?

The ABB ACS580-01 UL Type 4X variable frequency drive covers 1 to 30 HP (0.75 to 22 kW). Voltages are single-phase 240 V, and three-phase 208-240 V, 380-500 V and 500-600 V.

Orange and navy enclosure mounted on a gray panel with a cable gland at its base, beside a coiled black cable and a wrench.
Drive sits flush on a backplate, secured by four corner screws for quick removal.

In addition, standard hardware includes a DC choke, integrated STO (safe torque off), an integrated EMC C2 filter and coated circuit boards. It also has two option slots and a removable RS-485 terminal.

Where can the ACS580 4X run?

First, ABB’s catalog gives an ambient range of -13 to 122 °F (-25 to 50 °C), non-condensing, while ABB’s 5.5-22 kW flyer gives -20 to 50 °C. ABB derates the drive by 1% per 1 °C between 40 and 50 °C. Since 50 °C is the upper limit, the drive does not run derated above it. Also, the drive resists UV, but ABB says a sun shield is required outdoors. ABB’s flyer for 5.5 to 22 kW targets food and beverage, wash-down or dry zones, and says its corrosion and UV resistance is comparable to a stainless-steel enclosure.

Next, order it with the +B066 code. Distributor listings also show +F254 for an input disconnect version. However, confirm that code in ABB’s type-code table before you order.

Also, keep in mind that the standard wall-mounted ACS580-01 is UL Type 1 (IP21), and ABB lists other versions in Type 12. Those are not 4X. In addition, some reports say the ACS580 4X datasheets show IP69, but ABB’s catalog and flyer state IP66. Check the datasheet for your exact drive.

Where do the ACS580 4X type codes, fuse sizes and SCCR figures come from?

They come from ABB’s documents, and you should read them for your exact drive. The ACS580 technical catalog holds the type-code table and the option codes. The ACS580-01 hardware manual holds the fuse sizes, cable sizes and short-circuit current rating (SCCR) for each frame.

For example, the sun shield for outdoor use is an option code, listed as +C193 by some sources. Confirm it in the type-code table before you order. We do not list fuse or SCCR values here, because they change with the drive size and voltage.

ABB ACH580 4X for HVACR

What is the ABB ACH580 4X and when is it used?

The ACH580 4X is an ABB UL Type 4X variable frequency drive for outdoor HVACR installs, such as rooftop and cooling tower pumps and fans. It includes flying start, multi-pump control, freezestat response, resonance monitoring and fire override.

In addition, options include a built-in disconnect and a sun shield. For example, with the disconnect, you need no branch-circuit fuses, and the 100 kA SCCR (short-circuit current rating) holds. ABB also offers an optional Bluetooth control panel that works up to 250 feet (75 m). ABB’s own wording on Bluetooth varies, so confirm it in the type-code table.

What are the ACH580 4X ratings?

ABB lists the ACH580 4X from 1 to 30 HP. The supply options are single-phase 240 V and three-phase 208-240 V, 380-480 V and 500-600 V.

For the type code that matches your motor, use the type-code table in ABB’s ACH580 documents. Then match the output amps to your motor’s full-load amps, not hp alone.

ABB ACQ580 4X for water and wastewater

Does ABB have other 4X options, such as the ACQ580 4X?

Yes. The ACQ580 4X is ABB’s Type 4X/IP66 drive for water and wastewater. It is the water-focused sibling of the ACS580 and ACH580, with software built for pumps.

So how do they compare? Choose the ACQ580 4X for pumping and treatment jobs. Choose the ACS580 4X for general wet or outdoor loads, and the ACH580 4X for outdoor HVACR. We do not list the ACQ580 power range here, so read it in ABB’s ACQ580 documents.

ACS255 models, ratings and type codes

How do I read an ACS255 type code?

Take ACS255-03U-02A3-2+B063+F278 as an example. Read it in parts:

Isometric illustration of an orange-and-gray ABB NEMA 4X drive enclosure beside a tray of screws, blank cards, and a pen.
The orange front cover has raised bosses where the fasteners seat during reassembly.
  • 03: three-phase supply. 01 means single-phase supply.
  • U: no EMC filter.
  • 02A3: 2.3 A. In the xxAy format, xx is the whole number and y is the decimal.
  • -1, -2, -4: 115 V, 230 V and 480 V class.
  • +B063 / +B068: IP66 indoor or IP66 outdoor enclosure.
  • +F278: disconnect, FWD/REV/OFF selector and speed potentiometer.

Also, always check the type code and the drive nameplate. Because some web listings mislabel the phase or the output voltage, do not trust a title alone.

What 0.5 HP ABB NEMA 4X models are available and what are their ratings?

All 0.5 HP ACS255 drives are frame E1 (0.37 kW). First, we list the models below. In addition, each one comes in an indoor +B063 form, with or without +F278.

Type code (base)SupplyOutputAmps
ACS255-01U-02A3-1100-120 V, 1-phase240 V, 3-phase2.3 A
ACS255-01U-02A3-2208-240 V, 1-phase240 V, 3-phase2.3 A
ACS255-03U-02A3-2208-240 V, 3-phase240 V, 3-phase2.3 A
ACS255-03U-01A2-4400-480 V, 3-phase480 V, 3-phase1.2 A

We also list outdoor +B068 versions of the two single-phase models, the -1 and the -2. Check the product pages for the full list.

What else is in the ACS255 range?

However, the range goes well past 0.5 HP. ABB’s catalog lists 1.0 HP at 4.3 A (240 V class) and 1.0 HP at 2.2 A (480 V class). It also lists 1.5 HP at 3.3 A and 2.0 HP at 4.1 A at 480 V. Then larger +B068 outdoor-code drives run from 15 to 30 HP at 480 V in frames E3 and E4.

In addition, the 600 V class is a separate family with its own manual. It covers 1 to 15 HP in frames P2 and P3, from ACS255-03U-02A1-6+B063 up to ACS255-03U-17A0-6.

Indoor +B063 or outdoor +B068?

What is the difference between +B063 and +B068?

ABB’s type designation key defines +B063 as IP66 indoor and +B068 as IP66 outdoor. However, ABB’s catalog also describes the NEMA 4X IP66 enclosure as “for indoor use.” ABB’s own documents are not fully clear here.

So we say it plainly. Do not assume a +B063 drive is acceptable outdoors. For an outdoor install, order a +B068 part and follow the installation section of the ABB ACS255 user manual.

Does ABB permit outdoor mounting of the ACS255?

The manual says indoor use only, while the key labels +B068 as outdoor. Because the two do not match, get the answer in writing before you mount a drive outside.

First, ask ABB’s drives technical support, or send us the full type code and the site details. Then we can confirm it with ABB for you. Until you have an answer, treat an outdoor ACS255 install as unconfirmed. If you need an outdoor-proven choice, the ACS580 4X with a sun shield is rated for indoor and outdoor use.

With or without the +F278 operator controls

What does +F278 add and do I need it?

The +B063 code alone is an IP66/UL Type 4X enclosure with no input disconnect. However, adding +F278 gives you an input disconnect, a FWD/REV/OFF selector and a speed potentiometer.

Choose +F278 for a stand-alone, machine-mounted drive that needs local on/off, direction and speed. Instead, choose the plain version when a PLC, a remote start or a separate disconnect handles control. In short, +F278 saves you from wiring those parts yourself.

EMC filters and motor cable length

Which ACS255 and ACS580 4X models have an integrated EMC filter?

The ACS580-01 4X has an integrated EMC C2 filter as standard. The ACS255 “U” types, such as ACS255-03U-02A3-2, have no filter. The “U” in the type code tells you that.

Three workers in navy uniforms inspect a navy and orange drive unit in a metal enclosure, with cables routed along a cable
The open door reveals the mounting plate and a gray box beside the housing.

If you use a “U” drive where you must meet EMC limits, you need an external filter. ABB’s ACS255 technical catalog lists the filters that match each rating. Also, the maximum motor cable length depends on the drive, the filter and the EMC category you must meet. Read that limit in the manual for your drive, and do not guess it.

Which ABB NEMA 4X drive fits which application

Which ABB NEMA 4X drive fits my application?

Match the drive to the load and the place:

  • Small machine-mounted loads (conveyors, mixers, small pumps and fans): ACS255.
  • Wet process, food and beverage, or outdoor pumps, fans and compressors at 1 to 30 HP that need STO, an EMC filter and more I/O or fieldbus: ACS580-01 4X.
  • Rooftop, cooling tower and other outdoor HVAC pumps and fans: ACH580 4X.
  • Water and wastewater pumping: ACQ580 4X.

For larger or cabinet-built needs, ABB lists other ACS580 versions, such as Type 12 and 3R packaged drives. These are alternatives, not 4X drives.

How ABB NEMA 4X drives compare with alternatives

How does the ACS255 compare with the ACS580 4X?

The ACS255 starts at 0.5 HP and suits simple, machine-level jobs. The ACS580 4X starts at 1 HP and tops out at 30 HP. In addition, it adds integrated STO, an integrated EMC filter, a DC choke and two option slots. As a result, it fits plants that need a fuller I/O and fieldbus setup.

How does an ABB NEMA 4X drive compare with a standard drive in a separate enclosure?

A standard IP20 or Type 1 drive in a separate 4X box can work. However, you then pay for the box, the labor and the space, and you must check the heat inside it. In contrast, a drive built to Type 4X avoids that work. Also, it is one rated unit instead of two parts.

What mistake should you avoid?

Do not pick by IP number alone when the spec says NEMA 4X. Instead, check for the Type 4X marking on the drive.

What buyers ask before ordering

What should I confirm before ordering?

  1. Supply voltage and phase. Match the -1, -2 or -4 code, and check single-phase versus three-phase input.
  2. Motor amps. Compare the motor’s full-load amps with the drive’s output amps, not hp alone.
  3. Braking. Some ACS255 ratings include an internal braking transistor. The manual has a table that shows which. For example, the 5 HP ACS255-03U-18A0-2+B063 has one.
  4. Disconnect and fuses. Check the manual’s fuse and cable tables. The ACH580 4X disconnect option removes the need for branch-circuit fuses.
  5. Indoor or outdoor code. Pick +B063 or +B068 to match the site.
  6. EMC filter. Check whether your drive has one built in or needs an external filter.

Where do I find the ABB ACS255 manual, catalog and type-code tables?

Look in ABB’s online document library. The ABB ACS255 technical catalog has the ratings, fuses, cable sizes, braking resistors and type codes. There are separate ABB ACS255 user’s manuals for the 115-480 V range and for the 600 V variants. For the ACS580 4X, use ABB’s ACS580 technical catalog and the IP66/Type 4X flyer.

The NEMA website has the NEMA 250 enclosure types. However, for price and lead time, use our product pages, because those change.

Installing and commissioning a NEMA 4X ABB drive

How do I install and set up an ABB NEMA 4X drive?

First, mount the drive where ABB’s manual allows. Keep the sealed top cover in place. Next, use conduit-rated fittings and open only the separate terminal access cover. Do not drill or add openings that are not Type 4X rated.

Technician in gloves fits a cable gland to a gray enclosure near tools and a motor for an ABB NEMA 4X drive.
Sealed top cover stays closed while the gloved hand positions the conduit fitting.

Outdoors, put a sun shield on the ACS580 4X. Also keep the ambient temperature at or below 50 °C, expect derating of 1% per 1 °C between 40 and 50 °C, and keep the air non-condensing. For the ACS255, use the built-in macros and set the essential parameters. Then enter the motor nameplate data, and use the manual’s parameter list.

In addition, both families offer Modbus RTU over RS-485.

What cable glands, conduit fittings and torque values keep the 4X rating?

Use cable glands and conduit fittings that carry a Type 4X rating, and choose liquid-tight types. Match each fitting to the cable or conduit size and to the entry in the drive. Also, seat the gasket or sealing ring fully, and fit a blanking plug in any unused entry.

Torque matters too. Over-tightening can crack a gland plate, and under-tightening leaks. We do not give numbers here, because they differ by drive size and fitting. Use the torque tables in the drive’s manual for the terminals and the cover screws, and follow the fitting maker’s torque for the gland.

What are the common mistakes with NEMA 4X drives?

  • Choosing by IP rating alone.
  • Using a +B063 drive outdoors.
  • Adding a fitting, fan or hole that has no Type 4X rating.
  • Trusting a web title instead of the type code.
  • Skipping the sun shield on an outdoor ACS580 4X.

When to repair, replace or call for help

What do the fault codes and warnings mean, and how do I troubleshoot?

Each drive family has its own fault and warning list, so we do not list codes here. The ACS255 user manual has the fault codes for that drive. For the ACS580 4X, ACH580 4X and ACQ580 4X, read the fault tracing section of ABB’s firmware manual for your drive.

Meanwhile, these steps help with most faults:

  1. Write down the fault code and what the drive was doing when it tripped.
  2. Check the fault history, then reset the fault only after you know the cause.
  3. Check the supply voltage and phases at the drive input.
  4. Check the motor, its cable and its nameplate data against the drive settings.
  5. Look for moisture, corrosion or a damaged seal inside the enclosure.

If the fault returns, send us the code and the type code. Then we can help you decide between a repair and a replacement.

When should I repair or replace a NEMA 4X drive, and what do I give you to quote a replacement?

First, look for signs of water getting in: a damaged gasket or cover, moisture, or corrosion on terminals. Because a breached seal costs you the 4X rating, fix the seal either way. Then repair the drive if the fault is inside and the enclosure is sound. Replace the unit if the enclosure or seal cannot be restored.

Before you order a replacement, read the type code on the drive label. B063 versus B068 and F278 all matter. To get a quote, send us these items:

  • The full type code from the drive label.
  • A photo or copy of the drive nameplate.
  • Your motor’s full-load amps.
  • The supply voltage and phase.
  • Whether the site is indoor or outdoor.

We can also source discontinued ACS250 and ACS550-era drives, and repair failed ones.

Frequently asked questions

What does NEMA 4X mean on an ABB drive?

The enclosure is rated to NEMA 250 Type 4X, shown by ABB as UL Type 4X/IP66. Type 4X is NEMA 4 plus corrosion resistance. It covers hose-directed water, dust and ice, for indoor or outdoor use.

Which ABB VFDs are NEMA 4X rated?

These are the ACS255 IP66/NEMA 4X micro drives (+B063 indoor and +B068 outdoor codes), the ACS580-01 UL Type 4X/IP66 drive (1 to 30 HP, +B066), the ACH580 4X for HVACR and the ACQ580 4X for water and wastewater. Standard IP20 or Type 1 drives are not NEMA 4X.

Is NEMA 4X the same as IP66?

No. A NEMA 4X enclosure meets IP66, but an IP66 enclosure is not automatically 4X. IP does not test corrosion, icing or gasket aging. ABB’s drives carry both markings.

What do +B063, +B068 and +F278 mean on an ACS255?

+B063 is the IP66/UL Type 4X indoor enclosure and +B068 is the IP66 outdoor enclosure. +F278 adds an input disconnect, a FWD/REV/OFF selector and a speed potentiometer.

Can I mount an ABB NEMA 4X drive outdoors?

ABB’s ACS255 key labels +B068 as IP66 outdoor, while its catalog describes the NEMA 4X enclosure as for indoor use. So use +B068, follow the manual and confirm it with ABB or with us. The ACS580 4X is rated indoor/outdoor, but ABB says a sun shield is required outdoors.

Do ABB NEMA 4X drives need a separate enclosure?

No. You can mount them directly on the machine or process equipment. However, any opening you add must carry the same Type 4X rating, or the rating is lost.

The right abb nema drive comes down to the environment, the supply voltage, the motor amps and the options you need. Check the type code against ABB’s manual before you order. If you want help choosing, a quote or a repair, contact Precision Electric or browse our ABB drives.