If you search for the acs355, you probably have one in a panel, need to replace a failed unit, or are speccing a drive for a machine. This guide covers what the drive is, its ratings, how to read the type code and which enclosure you need. It also covers where to find the manuals and what ABB’s obsolete status means for you.

On this page

What the ABB ACS355 is

What is the ABB ACS355 VFD?

The ABB ACS355 is ABB’s machinery drive family. It is a variable frequency drive (VFD), a device that changes motor speed by changing the frequency and voltage it sends to the motor. In addition, it runs AC induction motors and permanent magnet motors from 0.37 to 22 kW (0.5 to 30 hp). You can mount it on a wall or inside a cabinet.

Who is the ACS355 for?

ABB designed the ACS355 for cabinet installation. For example, original equipment makers (OEMs), machine builders and panel builders used it most. Typical jobs include conveyors, pumps and general machinery. Because it is compact and easy to set up, it showed up in many small and mid-size machines.

Is the ABB ACS355 still available?

No, not as a current-production drive. First, ABB’s life cycle statement lists the ACS355 as Obsolete since 1.1.2026. In that phase ABB says the product is no longer available. However, an older ABB sales ramp-down notice gave 1.7.2026, and the later statement is the one to trust.

As a result, this guide mainly helps people who maintain or replace installed drives. For example, you can still source repaired or stocked units through distributors. In addition, ABB offers a path to the ACS380, which we cover below.

Key features built into the ACS355 drive

What features come standard?

The ABB ACS355 drive packs a lot into a small case. Here are the standard features ABB lists:

Isometric illustration of an open control cabinet with a gray and orange drive mounted on a DIN rail, a display panel, and a
Color-coded leads run from the lower housing up to the keypad.
  • Sensorless vector control for induction and permanent magnet motors, so you need no feedback device.
  • Safe torque off (SIL 3), which removes torque from the motor for safety.
  • Application macros and panel assistants for quick start-up. A macro is a preset group of parameters for a common job.
  • Also, up to eight pre-set operation sequences, which you build with the PC tool. These can cut the logic you need in an outside PLC.
  • Side-by-side mounting and a shared height and depth across the IP20 family.
  • A built-in brake chopper, which works with a brake resistor to handle braking energy.
  • Finally, FlashDrop, which loads parameters into a drive that is not powered.

Does it support permanent magnet motors and safe torque off?

Yes to both. The ACS355 controls asynchronous induction motors and permanent magnet synchronous motors. Also, safe torque off at SIL 3 comes standard, so you do not buy it as an add-on.

How do you choose a brake resistor for the built-in brake chopper?

The brake chopper only switches braking energy into a resistor that you add outside the drive. First, pick a resistor whose value is not below the minimum resistance ABB lists for your drive size. A lower value can overload the chopper. Next, check that the resistor can absorb the braking energy of your load without overheating.

The user’s manual lists the resistor data for each drive type, so use that table. Input chokes and external EMC filters also depend on the drive type, so check the catalog for the right ones.

What fieldbus options does it support?

The ACS355 has an embedded fieldbus for Modbus. In addition, optional modules add PROFIBUS DP, CANopen and DeviceNet. You can also add auxiliary I/O modules, an MTAC pulse encoder interface, an MREL relay module and an MPOW external auxiliary power supply module.

Each drive on a network needs its own address. For example, the embedded fieldbus default station address is 2, set with parameter 53.02 EFB STATION ID.

For wiring, programming and start/stop depth, see the Precision Electric training lessons 2, 7 and 8 and our Emergency Stop post. We do not repeat them here.

ACS355 models, voltage classes and ratings

What input voltages does the ACS355 accept?

ABB’s catalog lists three supply classes, all at 48 to 63 Hz:

  • Single-phase 200-240 V (±10%), 0.37 to 2.2 kW (0.5 to 3 hp).
  • Next, 3-phase 200-240 V, 0.37 to 11 kW (0.5 to 15 hp).
  • Finally, 3-phase 380-480 V (±10%), 0.37 to 22 kW (0.5 to 30 hp).

Frame sizes run from R0 to R4. For example, smaller drives sit in R0 to R2, and the largest in R4.

What hp sizes and current ratings are there?

The table below shows ratings from ABB’s catalog and datasheets. However, it is a sample, not the whole range. So open the catalog for every size.

Type codeSupplykWhpOutput ampsFrame
ACS355-01X-02A4-2230 V, single-phase0.370.52.4R0
ACS355-01X-04A7-2230 V, single-phase0.7514.7R1
ACS355-01X-06A7-2230 V, single-phase1.11.56.7R1
ACS355-01X-07A5-2230 V, single-phase1.527.5R2
ACS355-01X-09A8-2230 V, single-phase2.239.8R2
ACS355-03X-24A4-23-phase 230 V5.57.524.4R3
ACS355-03X-31A0-23-phase 230 V7.51031.0R4
ACS355-03X-46A2-23-phase 230 V111546.2R4
ACS355-03X-23A1-43-phase 480 V111523.1R3
ACS355-03X-31A0-43-phase 480 V152031.0R4
ACS355-03X-38A0-43-phase 480 V18.52538R4
ACS355-03X-44A0-43-phase 480 V223044R4

The X in each code stands for the letter that changes with phase and filtering. We explain it next.

How to read an ACS355 type code

What does each part of the code mean?

The type code tells you almost everything about the drive. For example, take ACS355-03U-15A6-4+B063 and read it left to right:

Isometric illustration of a navy and orange drive enclosure beside tags, a magnifying glass, a pencil, and small blocks on a
The orange side panel has a window, so you can check the display first.
  1. ACS355 is the series.
  2. Next, 03 means 3-phase input. A 01 means 1-phase.
  3. Then U is the letter that varies with phase and EMC filtering. You will also see E.
  4. After that, 15A6 is the current code.
  5. Then -4 is the voltage code. A -2 means 200-240 V, and -4 means 380-480 V.
  6. Finally, +B063 is an option code. This one gives IP66/IP67/UL Type 4X.

So always read the full code, including the plus codes. Two drives that look alike can have different options.

What is the difference between E-type and U-type drives?

The E and U versions differ in the EMC filter and in the default settings. An E-type drive ships with the EMC filter screw connected, and its defaults suit 50 Hz supplies. A U-type drive ships with the filter screw disconnected, and its defaults suit 60 Hz supplies.

As a result, E-type suits Europe and other 50 Hz regions, while U-type suits North America. You can change the filter screw and the parameters later if your site needs it. However, check the user’s manual before you move a screw, because the right setting depends on your supply grounding.

Where is the type label?

The type designation label sits on the left side of the drive. For example, one label in ABB’s manual shows ACS355-03E-08A8-4, 4 kW (5 HP), input 3~400 V / 480 V. You can also read the rating from the drive itself. In addition, parameter 3304 DRIVE RATING shows current and voltage ratings, and 3301 FIRMWARE shows the firmware version.

What are the J400, J404 and F278 codes?

We did not find an ABB page that explains these option codes, so we describe them only as they appear on our product pages. +J400 is listed as an advanced keypad and +J404 as a basic keypad. Likewise, +F278 is listed as an integrated disconnect, speed pot and forward/reverse switch. Before you order, check the exact option details with us.

Enclosures: IP20, NEMA 1 and NEMA 4X

Is the ACS355 NEMA 1 or NEMA 4X?

The base ABB ACS355 variable frequency drive is neither. It is IP20 / UL Open type, so it must go inside a cabinet. However, you can add the other ratings with kits or options:

  • NEMA 1 / UL Type 1: add a MUL1 kit. Use MUL1-R1 for frames R0 to R2, or MUL1-R3 or MUL1-R4 for those frames. The kit includes a hood and a connection box.
  • IP66/IP67/UL Type 4X: order the +B063 option. It is available up to 7.5 kW.

What are the limits of the 4X option?

External options are not available in the IP66/IP67/UL Type 4X class. However, IP69K is available for the IP66/IP67 variant with compatible cable glands. Also, ABB’s manual instructions cover IP20 drives. For NEMA 1, use the instructions that come with the MUL1 kit.

Which enclosure do you need?

Match the enclosure to the room. First, if the drive sits in a clean, enclosed panel, IP20 is fine. If it mounts on a machine in a dusty area, however, NEMA 1 adds a hood and connection box. Finally, for wash-down or wet areas, choose +B063 and keep the 7.5 kW limit in mind.

Which ACS355 fits your motor and supply

How do you choose the right ACS355 for your motor?

First, start with the motor nameplate. Match the motor’s full-load amps, not just hp, to the drive’s rated output current in ABB’s ratings table. Then confirm the supply: phase, voltage and 48 to 63 Hz. Finally, confirm the enclosure and any keypad, fieldbus or I/O options.

Here are worked examples using items we sell:

  • 1.5 hp on 208-240 V single-phase: ACS355-01U-06A7-2, rated 6.7 A by ABB.
  • 10 hp at 240 V, 3-phase: ACS355-03U-31A0-2, rated 31.0 A by ABB.
  • 15 hp at 240 V, 3-phase: ACS355-03U-46A2-2, rated 46.2 A by ABB.
  • 15 hp at 480 V, 3-phase: ACS355-03U-23A1-4, rated 23.1 A by ABB.

Can an ACS355 run a motor from single-phase power?

Yes, but only up to 2.2 kW (3 hp). The drive takes single-phase input and sends three-phase power to the motor. However, larger motors on single-phase power need a different approach, such as a three-phase supply or another drive type.

Which ACS355 models does Precision Electric list?

The table shows our listed type codes. For some codes we left out hp until the shop confirms it. Also, we skip amp figures because they can differ from ABB’s table.

Type codeInputEnclosure or option
ACS355-01U-06A7-2Single-phase 208-240 VNEMA 1
ACS355-03U-06A7-23-phase 208-240 VNEMA 1
ACS355-03U-31A0-23-phase 208-240 VNEMA 1
ACS355-03U-31A0-2+J4003-phase 208-240 VNEMA 1, advanced keypad
ACS355-03U-31A0-2+J4043-phase 208-240 VNEMA 1, basic keypad
ACS355-03U-46A2-23-phase 208-240 VNEMA 1
ACS355-03U-23A1-43-phase 400-480 VNEMA 1
ACS355-03U-15A6-43-phase 400-480 VNEMA 1
ACS355-03U-15A6-4+J4003-phase 400-480 VNEMA 1, advanced keypad
ACS355-03U-15A6-4+J4043-phase 400-480 VNEMA 1, basic keypad
ACS355-03U-15A6-4+B0633-phase 400-480 VNEMA 4X
ACS355-03U-15A6-4+B063+F2783-phase 400-480 VNEMA 4X, disconnect, speed pot, fwd/rev switch

ACS355 vs ACS380 and the other ABB options

How does the ACS355 compare with the ACS380?

The ACS380 is ABB’s newer machinery drive, so it is the like-for-like step from the ABB machinery drive ACS355. It covers 1/3 to 30 hp at 200-240 V (one and three phase) and 380-480 V (three phase). In addition, it comes in EMC and fieldbus variants.

Isometric illustration of an open panel enclosure with two grey ACS355 drive units, cable glands, and a DIN rail.
The orange strip on the left unit’s top marks it apart from its neighbour.
FeatureACS355ACS380
Power range0.5 to 30 hp1/3 to 30 hp
Motor typesInduction and PMInduction, PM and synchronous reluctance
Safe torque offStandard (SIL 3)Integrated STO
Brake chopperBuilt inIntegrated
Remote accessPC toolRemote and Bluetooth access
StatusObsoleteCurrent

For the ACS380, ABB also lists adaptive programming, optional encoder feedback and EMC variants with an integrated filter. In addition, it names mixers, centrifuges, conveyors and cranes as typical uses.

Where does the ACS580 fit?

The ACS580 is ABB’s general-purpose line, which is a different class from the machinery drives. Also, distributor advice on replacements varies. So check any suggestion against your nameplate and your application.

Replacing or swapping an ACS355

What replaces the ACS355?

ABB publishes an ACS355 to ACS380 transition guide, so the ACS380 is the direct successor. However, it is not a drop-in replacement. The guide covers sizing, wire size and cooling. In addition, a swap needs re-commissioning because the parameters, terminals and keypad differ.

How do you swap one?

  1. First, start from the full type designation on the drive label. ABB’s guide shows ACS355-01U-03A7-2+N827 as its example, but check the PDF itself to confirm it.
  2. Next, use the guide’s sizing tables for 200-240 V and 380-480 V three-phase supplies to pick the ACS380 size.
  3. Then check the tables for wire sizes (supply, motor and PE) and for heat dissipation and cooling airflow.
  4. Finally, plan time to re-wire and re-program the new drive, then test it before you return the machine to service.

How do you set up macros, Modbus and the PC tools on a replacement?

First, pick the application macro with parameter 9902 APPL MACRO. The ACS355 offers presets such as ABB Standard, 3-wire, Alternate, Motor Pot, Hand/Auto, PID Control and Torque Control. Choose the one closest to your old wiring, then adjust from there.

For embedded Modbus (EFB), set parameter 9802 COMM PROT SEL to the standard Modbus choice. Then set the group 53 parameters: station ID (5302), baud rate (5303) and parity (5304). Also point the start and reference sources to the fieldbus, or the drive will ignore network commands.

To save time, copy parameters from the old drive with FlashDrop, which loads them into a drive that is not powered. You can also use ABB’s PC tool, DriveWindow Light, to read, edit and save settings.

ABB ACS355 PDF: manuals, catalogs and guides

Where can you download the ABB ACS355 PDF?

Go to the ABB Library and search for the ACS355 machinery drive. In addition, the ABB ACS355 product page links to its documents. Below is each abb acs355 pdf by ABB code, and when to open it:

Isometric illustration of a stack of navy-blue books, loose papers, a blank tablet, eyeglasses, and a gray box with orange
Manuals, a tablet, and reading glasses sit beside a cabled unit on the bench.
DocumentABB codeUse it for
User’s manual (Rev E, 2020-11-02)3AUA0000066143Installation, start-up, parameters
Catalog (Rev H)3AUA0000068569Ratings, options, type codes
IP66/67 / UL Type 4X supplement3AUA0000066066+B063 drives
Quick installation guide3AUA0000092940Fast wiring check
US hardware manual addendumLVD-PNMH01U-ENUS hardware notes
Capacitor reforming guide3AFE68735190Drives stored a long time

The Rev E manual includes both SI and imperial units and special US installation instructions. In addition, the US product guide points to a technical catalog, code 3AUA0000081917.

Which manual revision matches your drive?

Match the manual to the drive’s firmware. To find it, read parameter 3301 FIRMWARE on the drive. The Rev E manual applies to firmware 5.110 or later. Because parameter numbers and page numbers differ between revisions A, B, D and E, do not mix them.

Also remember that the manual’s instructions cover IP20 drives. For NEMA 1, use the MUL1 kit instructions too.

Installation and wiring basics to get right

What cable and grounding rules apply to an ACS355?

First, size the input and motor cables to carry the load currents and to meet local regulations. Next, use a conductor rated at least 70 °C (158 °F) continuous. Also, the PE (protective earth) conductor must have the same conductivity as the phase conductor.

For US installs, follow the Additional US requirements section in the manual. Because rules vary by site, check your local electrical code as well.

For step-by-step wiring and fuse sizing, use Precision Electric training lessons 1 and 6. We keep that detail there so this page stays short.

Common ordering mistakes and checks for the ACS355

What mistakes do buyers make?

Most ordering errors are easy to avoid. For example, watch for these:

Illustration of a gray drive-like unit with a power cord, beside a screwdriver, pliers, small terminal parts, and a parts
The blank label window on the front panel is where the order details belong.
  • Ordering by hp alone and ignoring output amps.
  • Also, ordering IP20 when the site needs NEMA 1 or NEMA 4X.
  • Mixing up the -2 (200-240 V) and -4 (380-480 V) codes.
  • Next, assuming single-phase input drives go above 3 hp.
  • Forgetting to put fieldbus, keypad and I/O options on the order.
  • Finally, using a newer manual revision for an older drive. Check the firmware first.

Why compare amps with ABB’s table?

Retail listings can show amp figures that differ from ABB’s type code or catalog values. For example, the listing may use a different basis, such as a motor-current rating. So before you order, compare the listing against ABB’s ratings table and your nameplate. If the numbers do not match, ask us.

Troubleshooting, repair and when to call us

How do you find faults and drive status?

The drive tracks its own faults and history. In addition, Precision Electric training lesson 11 covers fault monitoring, history and troubleshooting, and lesson 10 covers feedback monitoring. So start there before you pull the drive.

What do common ACS355 fault codes mean?

A fault stops the drive and shows a number and a name on the panel. An alarm only warns you, and it clears when the cause goes away. These are some common faults:

CodeNamePlain meaning
1OVERCURRENTOutput current is too high
2DC OVERVOLTDC bus voltage is too high, often from fast braking
3DEV OVERTEMPThe drive is too hot
4SHORT CIRCShort circuit in the motor or motor cable
6DC UNDERVOLTDC bus voltage is too low, often from a supply dip
9MOT OVERTEMPMotor temperature is too high
16EARTH FAULTGround fault in the motor or motor cable
22SUPPLY PHASEAn input phase is missing or the supply is unbalanced

The user’s manual lists every code. Check it for codes not shown here.

How do you reset an ACS355 fault?

  1. First, find and fix the cause. A reset without a fix brings the fault right back.
  2. Next, press the RESET key on the control panel while the fault shows.
  3. Or use a digital input. Parameter 1604 FAULT RESET SEL sets which input resets faults.
  4. If the fault stays, switch off the supply, wait for the display to go dark, and power up again.

When should you repair instead of replace?

Repair often makes sense for an obsolete unit. Because a repaired drive keeps your panel, wiring and parameters unchanged, you avoid re-commissioning. However, replace it when the drive is beyond repair or when you plan to move to the ACS380 anyway.

How do you tell the age of a stored drive?

Read the serial number on the type label. ABB serial numbers follow the pattern MYYWWRXXXX. The M is the plant, YY is the year, WW is the week and the rest is a running number. For example, a serial that starts with a plant letter and then 15 and 30 means week 30 of 2015.

If a drive has sat in storage for a long time, its capacitors may need reforming. ABB’s capacitor reforming guide, 3AFE68735190, covers the abb acs355 vfd among other drives. So follow its steps and times before you power up a stored unit.

Frequently asked questions

What is the ABB ACS355?

It is ABB’s machinery drive family for AC induction and permanent magnet motors, from 0.37 to 22 kW (0.5 to 30 hp). It has a compact wall- or cabinet-mount design. In addition, sensorless vector control and safe torque off (SIL 3) come standard.

Is the ABB ACS355 still available?

ABB’s life cycle statement lists the ACS355 as Obsolete since 1.1.2026 and says the product is no longer available in that phase. However, ABB offers an ACS355 to ACS380 transition guide. Also, repaired or stocked units may still come through distributors.

Where can I download the ABB ACS355 PDF manual?

The ABB Library lists the user’s manual, code 3AUA0000066143 (Rev E, 2020-11-02). In addition, the catalog is 3AUA0000068569 Rev H. Finally, the IP66/67 / UL Type 4X supplement is 3AUA0000066066.

What replaces the ACS355?

The ACS380 machinery drive is the direct successor, and ABB publishes a transition guide. However, plan to re-commission it, because the parameters, wiring and keypad differ.

Is the ACS355 NEMA 1 or NEMA 4X?

The base drive is IP20 / UL Open type and must go in a cabinet. However, NEMA 1 / UL Type 1 comes from a MUL1 kit. Also, IP66/IP67/UL Type 4X is the +B063 option, available up to 7.5 kW.

What voltages does the ACS355 run on?

It runs on single-phase 200-240 V (to 2.2 kW / 3 hp), 3-phase 200-240 V (to 11 kW / 15 hp) and 3-phase 380-480 V (to 22 kW / 30 hp). In addition, the supply frequency is 48 to 63 Hz.

The ACS355 is a capable machinery drive, but it is now obsolete, so most buyers either keep an installed unit running or plan a move to the ACS380. Before you order, read the type code, match motor amps to ABB’s table and choose the right enclosure. If you need a quote, a repair or help picking a drive, contact Precision Electric or browse our ABB ACS355 products.