Invertek USA: Optidrive Series, Ratings and Support Guide

Isometric illustration of an open gray enclosure holding an orange drive unit, with cables running to a wall-mounted motor

If you search for invertek usa, you probably need to know who stands behind the drives in North America, which Optidrive fits your job, and where to get help. In this guide, you will see the US office, the main series, the E3 part numbers and the 0.5 HP models, plus ordering checks, software and support.

On this page

Invertek Drives in the USA: who they are and what they make

Invertek USA is a short way to say the US side of a global drive maker. The parent, Invertek Drives, was founded in 1998 and is headquartered in the UK. Today it has offices in Europe, Asia and the Americas. Its core product is the variable frequency drive (VFD), which controls the speed of an AC motor.

Navy variable frequency drive cabinet with an orange stripe, wired to a gray electric motor, with a wire spool and pliers on
Cable loops from the cabinet base toward the motor, so check its strain relief.

What is Invertek USA?

For most buyers, invertek usa means the US sales and support side of the brand. However, the brand itself is global. The same Optidrive range is sold worldwide, and the US office helps with sales, technical questions and the local network of reps.

What is Invertek Drives USA LLC and where is it located?

Invertek Drives USA LLC is the US entity. According to Invertek’s own contact page, it sits at 1226 American Way, Libertyville, IL 60048. The phone is 847-549-3669, and the general email is [email protected].

Older business listings show a St. Louis address under a similar name. However, do not treat those as the current head office. Instead, use the Libertyville page on the Invertek website.

Who owns Invertek Drives?

Invertek Drives is a division of Sumitomo Heavy Industries. As part of that group, Invertek Drives USA LLC sells through factory reps, service centres and distributors. In addition, Invertek’s US network lists reps and service centres in many states. One example is Smith Automation, a factory rep in Fishers.

Are Invertek drives UL listed for US use?

Invertek states that the Optidrive range meets CE (Europe), UL (USA) and RCM (Australia) standards. Still, for a US job, check the datasheet or nameplate of your exact model. In addition, the E3 manual says the drive gives motor overload protection that follows the US National Electrical Code.

The Optidrive family at a glance

Invertek USA sells the full Optidrive line. First, Invertek groups it into general purpose, high performance, application specific and OEM drives. Next, the table lists each series with the ratings the sources give. If a rating is missing, the sources we used do not state it, so check the datasheet.

What Optidrive series does Invertek make?

SeriesGroupWhat the sources say
Optidrive E3General purpose110–480 V, single and 3-phase input, 0.5–50 HP on the current Invertek page
E3 for Single Phase MotorsGeneral purposeMade for PSC or shaded-pole single-phase induction motors
Optidrive E4General purposeNewer E-series drive; Invertek shows a comparison with E3
Optidrive P2High performance200–600 V, single and 3-phase input, simple PLC functions, built-in EMC filter; confirm the HP ceiling (350 or 400 HP) on the datasheet
Optidrive Eco HVAC and Eco PumpApplication specific200–600 V, 1–400 HP, IP20, IP55 and IP66/NEMA 4X
Elevator Core and ElevatorApplication specificDrives for lifts
Compact 2OEMDrive for OEM panels
CoolvertOEMFor BLDC compressors, heat pumps and CDUs

Invertek also advertises up to 5 years of warranty on all Optidrives. In addition, for the Invertek VFD United States range, the Invertek website lists every series on its Optidrive range page.

Several series can serve HVAC work. For example, Eco is built for it, and Invertek describes the E3 as suitable for a wide variety of HVAC jobs. Coolvert is the odd one out, because it targets compressors and heat pumps.

Which Optidrive fits which job

Most Invertek Drives America buyers fall into a few groups. To choose, match the load first, then the series.

Three variable frequency drives of increasing size sit on a shelf, each wired to an electric motor below, beside a wooden
Cable loops hang from each unit’s base, so check the run length before mounting.
  • E3: general conveyors, pumps, fans and mixers.
  • E3 with single-phase output: PSC or shaded-pole single-phase motors.
  • Eco: variable-torque fans and pumps.
  • P2: heavy overload, bigger power and simple PLC functions.
  • Elevator: lifts.
  • Compact 2 or Coolvert: OEM panels and compressors.

What is the difference between the Optidrive E3, P2 and Eco?

E3 is the all-round drive for small and mid-size machines. In contrast, P2 is the high-performance choice, with simple PLC functions, a built-in EMC filter and ratings up to 350 or 400 HP, depending on the source. Meanwhile, Eco is tuned for fans and pumps.

The overload rating is a key difference. For example, our own Eco overview describes Eco as mainly a normal-duty, variable-torque drive with a 110% for 1 minute overload rating. That is a shop document, not a manufacturer page. So for heavier loads such as crushers or cranes, P2 may be a better fit.

A US mixer maker gives a real example. First, it used E3 IP66/NEMA 4X drives from 0.5 HP to 30 HP. Then it chose P2 up to 250 HP for the larger mixers.

Which Optidrive is best for HVAC fans and pumps?

Start with Optidrive Eco. For fan and pump systems, Invertek lists multiple fan control, automatic resonance avoidance and an integrated fire mode. Eco HVAC covers 200–600 V up to 250 kW / 400 HP. However, for a small fan or pump on a simple setup, E3 can also do the job.

Optidrive E3 in detail: the series most invertek usa buyers start with

The E3 is a general purpose drive. For example, it comes in IP20 for panel mounting and IP66/NEMA 4X for fully sealed use. Inside, you get 14 basic parameters plus application macro functions, Modbus RTU, a keypad, and digital and analog I/O. Also, the drive has input surge suppression.

What are the voltage and horsepower ranges of the Optidrive E3?

The answer depends on the source. For example, the current Invertek page lists 110–480 V, single and 3-phase input, at 0.37–37 kW / 0.5–50 HP. An older ODE-3 user guide, however, lists 0.37–22 kW / 0.5–30 HP. In both, IP66 models stop at 22 kW / 30 HP. So confirm your exact model on its current datasheet.

Where can the E3 be installed?

The manual says all units are for indoor installation in controlled environments. For instance, IP20 units need a pollution degree 1 environment. In contrast, IP66 (NEMA 4X) units may be installed in pollution degree 2.

Also plan for derating, which means running the drive below full output in tough conditions. For IP20 (open) drives, derate 1% per 100 m above 1000 m, up to a maximum of 2000 m. For enclosed IP66 drives, the guides give 2.5% per 100 m instead, so do not apply the 1% figure to them. In addition, maximum humidity for IP20 drives is 95% non-condensing. For IP66 units, mount the drive vertically on a flat surface and keep the minimum clearances.

How do I read an Invertek ODE-3 part number?

Take ODE-3-120043-1F12-01 as an example. The pieces follow the manual’s code, plus what the shop’s product list shows.

  • ODE-3: the Optidrive E3 family.
  • Input voltage digit: 1 = 110–115 V, 2 = 200–240 V, 4 = 380–480 V. Look at the second digit after ODE-3-.
  • Rating digits: on the shop’s models they match the output amps. For example, 0043 goes with 4.3 A and 0012 with 1.2 A.
  • Filter position: F means an internal EMC filter. However, the ODE-3-110023 models show 0 there instead.
  • Last character: the enclosure. 2 = IP20.

For IP66, the letters depend on the manual. The older guide for three-phase output uses X for non-switched and Y for switched. In contrast, the single-phase-output guide uses A and B. The shop’s SKUs also use A and B.

Finally, read the whole code. For example, the ODE-3-120043 and ODE-3-120023 models share a supply voltage but differ in output. Likewise, the trailing -01 is part of the product code, so do not drop it.

What is the difference between IP20, IP66 non-switched and IP66 switched?

IP20 is the open panel version. As a result, it needs an enclosure that suits the room. IP66/NEMA 4X, in contrast, is the sealed version for mounting on or near the machine.

IP66 comes two ways. First, non-switched models are controlled from the keypad, terminals or a network. Second, switched models add switches on the front. Before you buy, check the user guide for the model to see exactly what those switches do.

Can I use an Optidrive E3 outdoors?

The shop’s IP66 listings are named “Outdoor,” and Invertek offers an IP66 Outdoor User Guide and a sun shade guide. However, the E3 manual says all units are for indoor installation in controlled environments. Before you put one outside, ask Invertek technical support to confirm your setup.

The 0.5 HP Optidrive E3 models we stock, compared

We list twelve 0.5 HP E3 models. Note that 0.37 kW equals 0.5 HP. In the table, we group them by supply and output. Also, other horsepower ratings exist in the E3 range.

Four gray DIN-rail-mounted modules, one orange module, and a small cooling fan with a cable, shown in an isometric
Units sit side by side along the mounting track, ready for panel wiring.
InputOutputAmpsIP20IP66 non-switchedIP66 switched
100–120 VAC 1-phase120 VAC 1-phase7.0IP20 model: ODE-3-110070-1F12-01None listedNone listed
208–240 VAC 1-phase240 VAC 1-phase4.3IP20 model: ODE-3-120043-1F12-01Non-switched model: ODE-3-120043-1F1A-01Switched model: ODE-3-120043-1F1B-01
400–480 VAC 3-phase480 VAC 3-phase1.2None listedNon-switched model: ODE-3-140012-3F1ASwitched model: ODE-3-140012-3F1B
100–120 VAC 1-phase240 VAC 3-phase2.3IP20 model: ODE-3-110023-1012Non-switched model: ODE-3-110023-101ASwitched model: ODE-3-110023-101B
208–240 VAC 1-phase240 VAC 3-phase2.3IP20 model: ODE-3-120023-1F12Non-switched model: ODE-3-120023-1F1ASwitched model: ODE-3-120023-1F1B

Which 0.5 HP Optidrive E3 do I need for my supply and motor?

First, match the supply you have. Next, match the motor type. For example, the first two rows have single-phase output, so use those only with PSC or shaded-pole single-phase motors. In contrast, the 2.3 A rows give three-phase output and suit three-phase motors.

The 400–480 V row is for a three-phase supply and a three-phase motor. Also compare the motor nameplate amps with the drive’s output amps. In addition, the 100–120 V input to 240 V three-phase output models suit sites with no 230 V supply.

Can I run a 3-phase motor from single-phase power with an Optidrive?

Yes, with the right model. The 2.3 A drives take a single-phase supply and give a three-phase output. To match your supply, pick the 100–120 V or the 208–240 V input version. However, do not use the single-phase-output drives for this job.

What fuse, breaker and cable sizes does a 0.5 HP E3 need?

Fuse, breaker and cable sizes depend on the model, the supply voltage and local code, and we do not list them here. Instead, take the values from the ratings tables in the user guide for your exact model, and check them against the National Electrical Code. The same guide gives the overload and short-circuit current ratings for that model.

How Invertek compares with the alternatives

Compare drives by design intent, not by brand. For example, the E3 offers a 110 V input option and a single-phase-output variant. In addition, it has an IP66 option through 30 HP.

How does Invertek compare with other VFD brands?

For every drive you consider, check the same points, whether it is Invertek, Lenze, Eaton, ABB or Yaskawa:

  • Motor full load amps and drive output amps
  • Overload class and duty type
  • Enclosure rating and mounting
  • EMC filter
  • Fieldbus support
  • UL listing and physical size

For another view, our Lenze USA VFD Drives post gives a like-for-like alternative to read alongside this one.

Can an Invertek drive replace another brand’s VFD?

Often it can, but check it first. First, gather the motor nameplate, load type, supply, control wiring, communications and tuning values from the old drive. Then compare them with the Invertek datasheet. If any item does not match, treat the job as a redesign, not a swap.

What to confirm before you order from Invertek USA channels

A wrong part number costs time. So run through this list before you buy.

Worker in gray uniform and safety glasses checks an orange drive unit on a stacked pallet of boxes beside a wooden crate.
The open timber case holds a small meter and coiled cable beside the stack.

What should I check before ordering an Invertek drive?

  1. Supply voltage and phase, and whether you need single-phase or three-phase output.
  2. Motor nameplate full load amps, not just horsepower.
  3. Enclosure and mounting spot, plus ambient temperature and altitude derating.
  4. Control method: keypad, terminals, potentiometer, Modbus or another network.
  5. Options such as a keypad, comms gateway, EMC filter, choke or brake resistor.
  6. The full part number, including the suffix.

What warranty does Invertek offer?

Invertek advertises up to 5 years of warranty on all Optidrives. However, the words “up to” matter. So confirm the exact terms and lead time with the seller before you buy.

How do I start a warranty claim?

First, collect the full part number, the serial number from the drive label, and a short description of the fault. Then contact the seller you bought from, or Invertek Drives USA technical support. They can tell you the terms that apply to your drive.

Manuals, software and the Optidrive Passport

Invertek Optidrive USA buyers can get most documents from the Invertek website. As a result, you do not need a separate source.

Where do I download Optidrive manuals and software?

The Optidrive E3 documentation page offers the IP20 User Guide, the IP66 Indoor and Outdoor User Guides, the IP66 Quick Start Guide, the IP66 Sun Shade guide and CAD drawings. The Invertek software page hosts the PC tools. Also, the Optidrive Passport gives the datasheet, ecodesign data, factory test certificate and product documents.

For networks, Invertek’s communication interfaces page has a compatibility table and config files. In addition, external gateways connect up to four drives, or eight for Profibus, and suit all Optidrives. However, plug-in modules are for P2 and Eco.

Is Optitools Studio free?

Yes, you can download Optitools Studio free. The tool runs on Windows 7 SP1 through Windows 11. Also, it uploads, downloads and stores parameters, prints parameter lists and supports multi-drive networks. However, storing or uploading function-block PLC programs needs a licence.

Invertek also offers Optitools Pro, a newer tool for Windows 10/11, iOS 11+ and Android 6.0+. In addition, it adds 8 scope channels, real-time I/O monitoring, a flight recorder, trip code information and drive cloning.

Invertek USA support, service and repair

When a drive will not start, call the people who know it. In the US, the team handles technical questions, and the network of reps covers local needs.

Technician in hard hat and vest holds a handheld controller beside an open orange-doored drive cabinet, with a toolbox and a
A worker inspects the internal components before powering up the unit.

How do I contact Invertek Drives USA technical support?

Call 888-862-5659, which is toll free, or email [email protected]. Next, check the US contact page for current hours. The Libertyville page lists 8:30AM to 5PM CST, while the area page lists 8AM to 5PM EST, so do not rely on one time zone. Also, customers with an established account send purchase orders to [email protected].

What do the E3 trip codes mean, and how do I troubleshoot them?

Each E3 trip code has a meaning and a fix in the trip code table of the E3 user guide, so look up the code on the display there. Optitools Pro also shows trip code information when you connect to the drive. Before you reset, note the code and check the supply, the motor wiring and the motor amps. If the same trip returns, stop resetting it and call technical support or send the drive for repair.

What are common mistakes when installing an Optidrive?

  • Connecting the wrong motor type to a single-phase-output drive.
  • Installing an IP20 drive outdoors or in a dirty area.
  • Skipping the motor nameplate entries in the drive.
  • Ignoring derating limits for heat or altitude.

When should I send an Invertek drive in for repair?

Send it in after repeated trips, a dead display, or damage from a power surge. Also consider repair when a replacement would not be a like-for-like swap. Precision Electric offers a repair service, so contact us with the model and the fault.

Frequently asked questions

What is Invertek Drives USA LLC?

It is the US arm of UK-based Invertek Drives, a Sumitomo Heavy Industries division. Based in Libertyville, IL, it handles US sales and technical support. In addition, drives are sold through factory reps, service centres and distributors.

How do I contact Invertek Drives USA technical support?

The US technical support line is 888-862-5659 (toll free). You can also email [email protected]. However, check the US contact page for current hours, because two Invertek pages list different time zones.

What Optidrive should I choose for a general-purpose application?

Optidrive E3 is the general purpose series, with 110–480 V input, IP20 and IP66/NEMA 4X enclosures, and 0.5 HP and up. For fans and pumps, choose Eco. For demanding or heavy-overload loads, choose P2.

What do the letters at the end of an ODE-3 part number mean?

The last characters show the enclosure, where 2 is IP20. Next, IP66 is split into non-switched and switched, coded X/Y in the three-phase-output manual and A/B in the single-phase-output manual. Also, F in the filter position means an internal EMC filter.

Can an Optidrive E3 run a single-phase motor?

Only the E3 variants with single-phase output are meant for single-phase motors, specifically PSC or shaded-pole types. In contrast, the other E3 models give a three-phase output for three-phase motors, even from a single-phase supply.

Where do I download Invertek software and manuals?

The Invertek website hosts E3 user guides, quick start guides and CAD files. It also gives Optitools Studio free for Windows PCs. In addition, the Optidrive Passport gives datasheets and test certificates.

Invertek USA gives you a global drive line with local sales and support, and the E3 covers most small pump, fan, conveyor and mixer jobs. To choose well, match the supply, the motor amps and the enclosure, then read the full part number. If you want help choosing a drive, need a quote or have a drive to repair, contact Precision Electric or browse our Invertek Optidrive products.