Lenze Americas Corp: Drives, Models and Part Number Guide

Isometric illustration of an open electrical control cabinet with a orange-accented drive unit on a DIN rail, beside a

If you have a drive to replace or a small panel to build, you need to know what lenze americas corp sells today and which model fits. This guide covers the company, its AC Tech history, the i510 and i550 drives and the end of the SMVector. You will also learn how to read the part numbers and what to check before you order.

On this page

Who is Lenze Americas Corp (and what happened to AC Tech)?

What is Lenze Americas Corp?

Lenze Americas Corp is the American subsidiary of Lenze SE, a drive maker based in Hameln (Hamelin), Germany. The US business is headquartered at 630 Douglas St., Uxbridge, Massachusetts 01569. In addition, it sells AC inverters (variable frequency drives), servo drives and motor products, and it gives technical support for them.

Is Lenze Americas the same as AC Tech?

Yes. AC Tech is short for AC Technology Corporation, a company in Uxbridge that the Lenze group acquired. However, sources disagree on the year, so the safe answer is around 1999 to 2000.

After that, the US business used several names. For example, you will see Lenze AC Tech, Lenze AC Tech Corporation, A C Technology Corporation and Lenze Americas. Because they all point to the same US business, a part with an AC Tech label still comes from Lenze Americas.

Where is Lenze Americas located?

Lenze Americas runs from Uxbridge, Massachusetts. Also, it has an assembly and distribution center in Glendale Heights, Illinois. For a deeper company profile, see our earlier post on Lenze Americas.

Lenze / AC Tech drive families at a glance

What drive families does Lenze AC Tech sell?

The current general-purpose line is the i500 series, which means the i510 and the i550. Each comes as a cabinet drive (IP20, NEMA Open Type) and as a protec drive for harsher spots. Meanwhile, the protec versions are replacing the older SMVector (SMV) line.

Navy and white drive enclosure with vented sides beside an orange junction box, cable gland, coiled cable, and two mounting
Sealed lid and raised rim suggest protection against dust and moisture in harsher spots.

Older AC Tech names still show up in repair queues. These include the MC series, the SF series and M-series part numbers such as M1475B and M14100C. We repair these drives. However, this guide does not list ratings for them, and it does not name a replacement for each one. If you have one of these drives, send us the nameplate data and we will help you choose.

FamilyMountingPower rangeTypical use
i510 cabinetPanel, IP20 / NEMA Open Type0.25 to 15 kW (0.33 to 20 hp)Pumps, fans, conveyors, basic machines
i550 cabinetPanel, IP20 / NEMA Open Type0.25 to 132 kW (0.33 to 175 hp)Networked, safety and servo-type tasks
i510 / i550 protecReplacement for SMVector enclosuresSee the Lenze migration guideSMVector replacement
SMVectorNEMA 1 and NEMA 4XLegacy lineRepair and replacement

i510 cabinet from Lenze Americas: the basic panel-mount drive

What is the Lenze i510 and what power range does it cover?

The i510 is the simpler drive from Lenze Americas. Its range runs from 0.25 to 15 kW (0.33 to 20 hp), with IP20 / NEMA Open Type protection. In addition, it holds CE, UL, CSA, EAC and RoHS approvals, and the small sizes are about 60 mm wide and 130 mm deep.

The drive ships in two versions. One has basic I/O. The other has basic I/O plus CANopen and Modbus RTU. Because of this, the i510 suits pumps, fans, conveyors and other simple machine tasks.

How do I set up an i510 without a keypad?

You have three setup methods. First, you can use the keypad. Second, you can use the Smart Keypad app on a smartphone through a WLAN module. Third, you can use EASY Starter, the Lenze PC software.

So a drive sold without a keypad is not a problem. In addition, our post on commissioning the i500 with a smartphone walks through the app.

i550 cabinet from Lenze Americas: the modular, networked drive

What is the Lenze i550 and what options does it have?

The i550 is the modular drive in the Lenze Americas line. It covers 0.25 to 132 kW (0.33 to 175 hp). Next, you pick a control unit with the I/O or network you need, such as application I/O, CANopen, EtherCAT, PROFINET, EtherNet/IP or Modbus TCP.

Gray DIN-rail-mounted module with an orange front panel and RJ45 Ethernet cables, mounted on a white backplate with rails
Red, black and green conductors run along the upper channel, held by a tie.

This drive also adds control modes the i510 lacks. For example, it offers servo control with encoder feedback and V/f control with feedback. Servo control with encoder feedback is available on models up to 22 kW. Finally, some 400 V sizes can run in heavy-duty (high overload) or light-duty (low overload) mode.

The i550 has 5 digital inputs, 1 digital output, 1 relay output, 2 analog inputs, 1 analog output and a 0 to 100 kHz frequency input. Also, it connects a brake resistor for dynamic braking.

Does the i550 have Safe Torque Off?

Yes, as an option. Safe Torque Off (STO) removes the drive’s ability to make torque so the motor cannot start by accident. On the i550, STO is rated to SIL 3 and Performance Level e. Because it is a separate choice, check the option code when you order.

Is STO the same as an Emergency Stop?

No. STO stops the drive from making torque, but it does not cut the supply or isolate the motor from power. The motor can also coast to a stop, so a load with high inertia may keep moving for a while. As a result, an Emergency Stop usually needs extra measures, such as a safety relay and a mains contactor or other means set by your risk assessment.

For the STO terminals, wiring and response time, use the i550 operating instructions. We do not list those values here because they must match your exact model and safety design.

Lenze Americas protec versions and the SMVector changeover

Is the SMVector discontinued, and what replaces it?

Lenze is replacing the SMVector with the i510 protec and i550 protec. A distributor blog reports that last orders for the SMVector were May 1, 2026. However, that date comes from the distributor, not from Lenze, and it has now passed. As a result, treat the SMVector as a replacement and repair topic, and check stock before you count on a new one.

Lenze Americas runs an SMVector migration page with product selection, programming, mounting and wiring guides. Also, it offers a migration selection tool. In addition, our earlier posts on the product changeover and the SMVector manual downloads cover more.

Which protec model replaces my SMVector?

We do not give a model-by-model table here, because a wrong match can cost you time and money. Instead, read the full part number on your SMVector nameplate, such as an ESV or ESM number. Then enter it in the Lenze migration selection tool, or send it to us and we will help you match it. In either case, check the rated power, the supply voltage and the enclosure type before you order.

Will an i510 or i550 protec bolt into my SMVector’s place?

Often, but not always. The protec drives are similar in size to the SMVector. In fact, most i510 protec units share the mounting holes of the same-rated SMVector. Still, check the size table in the Lenze guide for your exact unit before you drill or order.

What changes when I swap an SMVector for an i510/i550 protec?

First, do not treat the swap as plug and play. Lenze says wiring and programming differ, and a distributor warns that motor wiring is different. Here are the main changes:

  • Wiring: motor wiring differs, so follow the new wiring guide.
  • Digital inputs: the assertion level is a programmable setting. The SMVector used a DIP switch.
  • EPM memory module: the SMVector uses a gray EPM. The protec drives use a white one. They do not interchange.
  • Extras on the i550 protec: an integrated brake chopper in all sizes and +24 V keep-alive.

Lenze Americas ratings and models: reading the part number

How do I read a Lenze i510/i550 part number?

Take I55AE125A10V01001S as an example. The “I” means inverter, and the “55” means i550 (“51” would mean i510). Next comes the generation: A is generation 1 and B is generation 2. Then the “E” means control cabinet mounting.

Isometric illustration of a navy and gray drive enclosure with orange terminal connectors on a workbench, beside coiled
Four amber plugs sit in a row with short cable loops hanging below.

Finally, the three digits give the rating, so 125 means 0.25 kW. The letter after the rating gives the mains supply:

  • A: 1-phase 120 V
  • B: 1-phase 230/240 V
  • D: 1- or 3-phase 230/240 V
  • C: 3-phase 230 V
  • F: 400/480 V

The other rating codes are 137 for 0.37 kW, 155 for 0.55 kW, 175 for 0.75 kW, 211 for 1.1 kW, 215 for 1.5 kW and 222 for 2.2 kW. In addition, the rest of the code, such as 10V or 1AV, names the control unit and options. Next, we decode those below.

What are the current ratings of the small i550 sizes?

First, here are the rated output currents at 8 kHz for the i550 on 120 V single-phase mains.

CodePowerRated output current
125A0.25 kW1.7 A
137A0.37 kW2.4 A
175A0.75 kW4.2 A
211A1.1 kW6 A

The 125A drive has a maximum output current of 3.4 A. However, the manual ties that figure to an overload time of 3 seconds and a recovery time of 12 seconds. In addition, the 120 V mains range is 90 to 132 V, and the 230/240 V single-phase range is 170 to 264 V.

For sizes above 2.2 kW, including the 400/480 V currents, heavy-duty and light-duty ratings and overload limits, use the rated data tables in the i510 and i550 operating instructions. Pick the row that matches your exact part number.

Our 0.33 HP Lenze AC Tech drives and where each fits

What do the i550 option codes mean?

On the i550 models we list, the code splits into two choices. First, “10V” means no STO module and “1AV” means the STO module is included. Second, the ending shows the control unit: 1001 is application I/O, 1002 is CANopen and 100K is EtherCAT. Also, a distributor’s listing shows PROFINET and EtherNet/IP versions with codes ending 07L and 07M.

Which 0.33 HP Lenze AC Tech drive should I order?

Start with your supply, then pick the I/O or network, and then decide on STO. The i510 versions use the 1.7 A rating. Likewise, the i550 sizes below are 0.25 kW (0.33 HP) and use 1.7 A.

SeriesMains (letter)Control unitSTOPart number
i510230 V 1-phase (B)Basic I/On/aI51AE125B10V11000S
i510230 V 1-phase (B)CANopen and Modbus RTUn/aI51AE125B10V11001S
i510230 V 1/3-phase (D)See listingn/aI51AE125D10V01000S
i550120 V 1-phase (A)Application I/ONoI55AE125A10V01001S
i550120 V 1-phase (A)Application I/OYesI55AE125A1AV01001S
i550230/240 V (D)Application I/ONoI55AE125D10V01001S
i550230/240 V (D)Application I/OYesI55AE125D1AV01001S
i550120 V 1-phase (A)CANopenNoI55AE125A10V01002S
i550120 V 1-phase (A)CANopenYesI55AE125A1AV01002S
i550230/240 V (D)CANopenNoI55AE125D10V01002S
i550230/240 V (D)CANopenYesI55AE125D1AV01002S
i550120 V 1-phase (A)EtherCATNoI55AE125A10V0100KS

All of these are sold without a keypad. However, our listing titles also state an output phase, and several do not match the manuals, which describe the mains input. Therefore, confirm the output on the nameplate or in the manual before you rely on it. Likewise, check the option code on the i510 D listing, because its title and code do not clearly agree.

The buying logic is simple. If the machine needs safety or a fieldbus beyond CANopen and Modbus, choose the i550. On the other hand, for fixed, simple loads, choose the i510.

i510 vs i550 vs SMVector: which one do I pick?

i510 or i550: which is right for my application?

First, use this table to decide between the two drives from Lenze Americas.

Isometric illustration of a navy and orange drive cabinet beside a smaller gray-and-navy unit, with fuses, wrenches
Note the worn housing on the right unit and the checklist beside it.
Needi510i550
Cabinet power range0.25 to 15 kW0.25 to 132 kW
Safe Torque OffNot listedOptional, SIL 3 / PL e
NetworksCANopen, Modbus RTUCANopen, EtherCAT, PROFINET, EtherNet/IP, Modbus TCP
Control modesStandard, including sensorless vector control for synchronous motorsAdds servo control (SC-ASM) with feedback and V/f control with feedback
BuildSingle pieceModular

If you replace an SMVector, the protec versions often fit the same footprint. Still, plan time for rewiring and reprogramming. In addition, for the i550 protec, the Lenze migration guide lists the brake chopper, EMC filter and 24 V keep-alive options.

How does Lenze Americas compare with other VFD brands?

We cannot give a fair brand-to-brand comparison here, because we found no manufacturer sources for one. So this guide compares only within Lenze: i510, i550 and the SMVector. If you are weighing another brand, compare nameplate ratings, options and approvals on each datasheet. Then call us with the numbers and we will help you narrow it down.

Installation and commissioning basics for Lenze Americas drives

What are the mounting size and terminal limits of the small drives?

The small i510 housings use M5 screws. Also, leave the clearance the manual specifies.

  • 0.25 to 0.37 kW: 155 mm high, 60 mm wide, 130 mm deep, 0.75 kg.
  • 0.55 to 0.75 kW: 180 mm high, 0.95 kg.
  • 1.1 to 2.2 kW: 250 mm high, 1.35 kg.

On the i550, the mains terminals for 0.25 to 0.37 kW take up to 2.5 mm² wire, with an 8 mm strip and 0.5 Nm torque. The 0.75 to 1.1 kW terminals take 6 mm² at 0.7 Nm, and the PE screw takes 2 Nm. Also, take fuse, circuit breaker, RCD and mains choke sizes from the rated and fusing data table in the manual for your exact model, not from a rule of thumb.

How do I commission a Lenze i510/i550?

First, wire the drive as the manual shows. Next, enter the motor nameplate data in the drive, and take care over the star or delta connection. Then run the motor for the first time. In addition, you can do the setup with the keypad, the Smart Keypad app or EASY Starter.

Which basic settings do I need before the first run?

Start with the motor nameplate. Enter the rated voltage, current, frequency, speed and power, and match the connection to how the motor is wired. Then set the V/f base frequency to the motor’s rated frequency, which is often 60 Hz in North America. Also set the acceleration and deceleration times to suit the load.

Next, choose how you will start and control the drive. A common setup uses one digital input for run and stop, and an analog input (0 to 10 V or 4 to 20 mA) for the speed reference. Then set the drive to take its commands from those terminals. Because parameter numbers vary by model and software version, find them in the manual or in EASY Starter.

Documents, software and where to get Lenze Americas parts

Where do I download Lenze manuals and software?

To handle the SMVector change, start with the Lenze SMVector migration page and the Lenze Americas SMVector to i510/i550 protec NEMA 1 guide. Next, use the Lenze i510 / i550 cabinet frequency inverter datasheet and the Lenze Inverter i500 catalog for specs. Then, for installation, use the i510 and i550 cabinet operating instructions and the i510 project planning guide.

Isometric illustration of a workbench holding a stack of documents, a tablet, an open orange-and-white electronics
Coiled cable hangs off the table edge, ready to run to the drive panel.

For software, download EASY Starter for your PC and the Smart Keypad app for your phone. However, some of these files sit on distributor sites. When you read one, remember that the distributor is not the manufacturer. In addition, you can buy the drives from our shop listings, and we repair Lenze and AC Tech drives.

Common mistakes and when to send a Lenze drive for repair

What mistakes do people make when ordering or replacing Lenze drives?

  • Assuming SMVector wiring, DIP-switch settings or the EPM carry over to the i510 or i550.
  • Ordering by HP only, and skipping the input voltage letter (A, B, D, C or F) and the options code.
  • Forgetting that STO is a separate option on the i550 (10V versus 1AV).
  • Skipping the motor data before the first run.

What should I check when my Lenze drive faults?

First, read the fault code on the keypad or in EASY Starter, and look it up in the fault table in the manual. We do not list the codes here, because meanings differ by model and software version. Next, turn off and lock out the power, and wait for the DC bus to discharge before you touch any wiring.

Then check the basics. Confirm the supply voltage is in range, the terminals are tight and the motor cable is sound. Also look for a jammed load, and check whether the acceleration time is too short for it. If the same fault returns after these checks, the drive may need repair.

When should I send a Lenze drive in for repair?

Send the drive in if it trips on overcurrent or overload again and again. Also send it in if it shows no display or no power after a surge, or if the power terminals are damaged. However, read the fault code against the manual first, because we will not guess at meanings here. Precision Electric repairs Lenze AC Tech drives.

Frequently asked questions

What is Lenze Americas Corp?

It is the American subsidiary of Lenze SE of Germany, headquartered at 630 Douglas St., Uxbridge, Massachusetts. It was formerly known as Lenze AC Tech, which grew from AC Technology Corporation. In addition, the Lenze group acquired that company around 1999 to 2000.

What is the difference between the Lenze i510 and i550?

The i510 is the simpler, single-piece drive for standard applications, up to 15 kW in the cabinet version. In contrast, the i550 is modular and goes up to 132 kW. Also, it adds options such as STO and more fieldbuses, along with servo control and V/f control with feedback.

Is the AC Tech SMVector still available?

Lenze is replacing the SMVector with the i510 protec and i550 protec. However, a distributor reports that last orders were May 1, 2026, so plan on replacement or repair. Also, wiring and programming differ, and the EPM modules are not interchangeable.

Does the SMVector EPM work in an i510 or i550?

No. Lenze says the gray SMVector EPM and the white EPM in the i510/i550 protec are not interchangeable.

What do the letters in an i510/i550 part number mean?

The “I” is inverter, and 51 or 55 is the i510 or i550. Next, the “E” is control cabinet mounting, and the three digits give rated power, so 125 is 0.25 kW. Finally, the letter after that gives the mains: A is 120 V 1-phase, B is 230/240 V 1-phase, D is 230/240 V 1/3-phase, C is 3-phase 230 V and F is 400/480 V.

Lenze Americas Corp gives you a clear path from older AC Tech drives to the i510, the i550 and the protec versions. Before you order, match the supply letter, the options code and the nameplate data. If you need a quote, a repair or help choosing a drive, contact Precision Electric or browse our Lenze products.